Honeywell ToxiRAE Pro Toxic Gas and Oxygen PGM-1860 series by RAE systems include data logging as standard.
A single gas detector giving real-time readings and STEL, TWA, and peak values. Each sensor has innovative technology, meaning the operator can swap the sensor for other gas types, up to twenty possible.
With wireless versions, real-time monitoring with warnings can be viewed from anywhere. The modem built into the detector uses the frequency 868 MHz. It is not possible to retrofit wireless on a model purchased without wireless capability.
| Detector Type | Single Gas Detector |
|---|---|
| Gas Readings | Real-time readings, STEL, TWA, and peak values |
| Data Logging | Configurable between 1 and 3600 seconds |
| Wireless Frequency | 868 MHz |
| Size | 118 x 60 x 30 mm |
| Weight | 220 g |
Standard Instrument Configurations
Wireless (868 MHz)
G02-AE13-100 – ToxiRAE Pro PGM-1860, O2, Datalogging, Wireless
G02-A213-100 – ToxiRAE Pro PGM-1860, CO (up to 500 ppm), Datalogging, Wireless
G02-A113-100 – ToxiRAE Pro PGM-1860, H2S (up to 100 ppm), Datalogging, Wireless
G02-A313-100 – ToxiRAE Pro PGM-1860, SO2, Datalogging, Wireless
Non-Wireless
G02-AE10-100 – ToxiRAE Pro PGM-1860, O2, Datalogging, Non-Wireless
G02-A210-100 – ToxiRAE Pro PGM-1860, CO (up to 500 ppm), Datalogging, Non-Wireless
G02-A110-100 – ToxiRAE Pro PGM-1860, H2S (up to 100 ppm), Datalogging, Non-Wireless
G02-A310-100 – ToxiRAE Pro PGM-1860, SO2, Datalogging, Non-Wireless
Replacement Sensors
C03-0950-000 – Ammonia (NH3) Sensor, Range: 0–100 ppm, Resolution: 1 ppm
C03-0903-000 – Carbon Monoxide (CO) Extended-Range Sensor, Range: 0–2,000 ppm, Resolution: 10 ppm
C03-0906-000 – Carbon Monoxide (CO) Sensor, Range: 0–500 ppm, Resolution: 1 ppm
C03-0979-000 – Carbon Monoxide (CO) Sensor, H2-Compensated, Range: 0–2,000 ppm, Resolution: 10 ppm
C03-0978-000 – Chlorine (Cl2) Sensor, Range: 0–50 ppm, Resolution: 0.1 ppm
C03-0956-000 – Chlorine Dioxide (ClO2) Sensor, Range: 0–1 ppm, Resolution: 0.03 ppm
C03-0954-000 – Ethylene Oxide (EtO-A) Sensor, Range: 0–100 ppm, Resolution: 1 ppm
C03-0922-100 – Ethylene Oxide (EtO-B) Sensor, Range: 0–10 ppm, Resolution: 0.1 ppm
C03-0923-100 – Ethylene Oxide (EtO-C) Extended-Range Sensor, Range: 0–500 ppm, Resolution: 10 ppm
C03-0982-000 – Formaldehyde (HCHO) Sensor, Range: 0–10 ppm, Resolution: 0.05 ppm
C03-0981-000 – Hydrogen (H2) Sensor, Range: 0–1,000 ppm, Resolution: 10 ppm
C03-0949-000 – Hydrogen Cyanide (HCN) Sensor, Range: 0–50 ppm, Resolution: 0.5 ppm
C03-0904-000 – Hydrogen Sulfide (H2S) Extended-Range Sensor, Up to 1,000 ppm Reading
C03-0907-001 – Hydrogen Sulfide (H2S) Sensor, Range: 0–100 ppm, Resolution: 0.1 ppm
C03-0980-000 – Methyl Mercaptan (CH3-SH) Sensor, Range: 0–10 ppm, Resolution: 0.1 ppm
C03-0974-000 – Nitric Oxide (NO) Sensor, Range: 0–250 ppm, Resolution: 0.5 ppm
C03-0975-000 – Nitrogen Dioxide (NO2) Sensor, Range: 0–20 ppm, Resolution: 0.1 ppm
C03-0942-000 – Oxygen (O2) Sensor, Range: 0–30% vol., Resolution: 0.1% vol.
C03-0908-001 – Liquid Oxygen (O2) Sensor
C03-0976-000 – Phosphine (PH3) Sensor, Range: 0–20 ppm, Resolution: 0.1 ppm
C03-0973-100 – Sulfur Dioxide (SO2) Sensor, Range: 0–20 ppm, Resolution: 0.1 ppm
Replacement Parts
G01-2005-010-FRU – Alligator Clip Assembly with Screw and Washers (Pack of 10)
G02-3004-000 – Rechargeable Li-ion Battery
G02-2029-000 – Protective Rubber Boot for ToxiRAE Pro (Non-PID)
Get in touch with us to see how we can help you with your project