The Oxygas 500 compliments the Gascoseeker 500 with similar performance, measuring % LEL and % volume of flammable hydrocarbons, but with the addition of oxygen for either gas/air or gas/nitrogen/air purging. The Oxygas 500 has additional features: automated zero during start-up and manually selectable purge mode.
The P-500 variant has an additional part per million (ppm) range of methane.
The Oxygas 500 is easy to use with straightforward training, as its operation follows the purge cycle. Its rugged design allows it to be used in harsh environments. The instrument is also fully compatible with our calibration software and equipment range.
| Order Code | Description |
|---|---|
| 42501X | OXYGAS 500 (Alkaline) |
| 42501XR | OXYGAS 500 (Rechargeable) |
| 42501P | OXYGAS P-500 (Alkaline) |
| 42501PR | OXYGAS P-500 (Rechargeable) |
The above instruments are supplied with:
| Order Code | Description |
|---|---|
| 13184 | Standard Charger c/w Universal Power Supply |
| 12988 | 12V Car Charger Lead |
| 13100 | Smart Charger & Datalogging Software c/w 240V Power Supply (UK Plug) |
| 13440 | Smart Charger & Datalogging Software c/w 220V Power Supply (Euro Plug) |
| 13340 | Smart Charger & Datalogging Software c/w 110V Power Supply (USA Plug) |
| 12890 | Smart Charger & Datalogging Software c/w 220V Power Supply (Australian Plug) |
| 99556 | FlexiCal Plus |
| 13427 | Plastic Probe – 35 cm Open End |
| 12393 | Plastic Probe – 80 cm Solid End |
| Order Code | Description |
|---|---|
| 13561 | Probe Handle |
| 13562 | Probe Handle Adaptor Assembly (use with 13561) |
| 42184 | In-line Dust Filter Assembly (use with 13561) |
| 42183 | In-line Water Filter Assembly (use with 13561) |
| 13563 | Bellows Cup Probe (use with 13561) |
| 12393 | Swan Neck Probe c/w Shroud (use with 13561) |
| Specification | Details |
|---|---|
| Measuring Ranges |
0 to 25% Oxygen (O2) 0 to 100% VOL GAS 0 to 100% LEL 0 to 1000 PPM Flammable (Oxygas P-500 only) |
| Resolution |
Oxygen (O2) 0 to 21%: 0.1% Oxygen (O2) 21% to 25%: 1% Vol Gas 0 to 100%: 1% LEL 0 to 10%: 0.1% LEL 10% to 100%: 1% PPM Flam. 0 to 1000: 5 ppm |
| Dimensions | 180 x 95 x 105 mm / 7.1 x 3.7 x 4.1in. |
| Weight | 1.7 kg / 3.75 lbs |
| Display |
LCD containing: 4-digit digital display Analogue display 3-character range indication Operational Flags |
| Humidity | 0-95% R.H. non-condensing |
| Temperature | -20°C to +50°C (-4°F to +122°F) |
| Sampling | Integral pump with flow fail sensor; sample path is protected filter and automatic pump switch-off |
| Battery | 4 ‘D’ size Alkaline Cells or Rechargeable Battery Pack |
| Battery Life | 15 hours Alkaline or 9 hours Rechargeable at 20°C (68°F) |
| Construction | Moulded polypropylene case |
| Rating | IP54 (Dust protected and splashproof) |
| Geiger (Ticker) | Indicates gas concentration increase in PPM range via the increased rate of sounder and LED pulse (Oxygas P-500 only) |
| Sensor Life |
Flammable: 5 Years Oxygen: 2 Years |
| Certification |
ATEX II 2 G EEx ia d IIC T4 (Ta = -20°C to +50°C) IECEx Ex ia d IIC T4 Gb (Ta = -20°C to +50°C) UL 913 Class I, Div 1 Groups A, B, C and D |
Get in touch with us to see how we can help you with your project