Dräger has developed miniature electrochemical sensors specifically for the Pac, X-am 1/2/5, and X-am 8000 generations. These sensors detect a wide range of gases and vapours while offering exceptional reliability and long-term stability, helping to reduce operating costs.

XXS in Size – XXL in Performance

Improved gas selectivity, combined with excellent long-term stability and rapid response times, ensures that users are quickly and reliably alerted to the presence of hazardous gases, enhancing workplace safety.

Sensor Diversity

In addition to the Dräger Sensors XXS H₂S, CO, and O₂, Dräger also offers sensors for hydride, amine, and organic vapours. Sensitivity data for more than 12 different gases and vapours stored on the XXS OV sensors enables the detection of multiple gas hazards using a single sensor.

Key Features

  • Miniature electrochemical sensors designed for Pac, X-am 1/2/5, and X-am 8000 devices.
  • Excellent gas selectivity with rapid response times for enhanced safety.
  • Outstanding long-term stability for reliable performance.
  • Wide range of sensor options for gases and vapours, including hydrides, amines, and organic vapours.
  • XXS OV sensors support sensitivity data for more than 12 gases and vapours.
  • Long calibration intervals help minimise maintenance requirements.
  • Sensor lifespan of up to five years, depending on sensor type.

Two in One Technology

The dual sensors combine the capabilities of two sensors into one compact unit. They enable simultaneous O₂ (% by volume) testing and ppm-level testing for CO or H₂S, setting new standards for efficient gas monitoring.

Internal Development

Dräger develops these sensors using its own engineering expertise, ensuring high quality and accurate measurements. This enables seamless integration and optimal performance with Dräger's complete range of in-house developed gas detectors.

Low Operating Costs

The sensors provide reliable measurement results with extended calibration intervals. Depending on the sensor type, they offer an operational lifespan of up to five years, helping to reduce overall operating costs.

Sensor Type Measuring Range Part Number
PID HC0 – 2000 ppm6813475
PID LC ppb0 – 10 ppm6813500
PID HC neo0 – 2000 ppm6800417
Set PID HC neo incl. sensor damper0 – 2000 ppm3703907
Dual IR Ex/CO2 ES0 – 100 Vol.-% CH4 / 0 – 100 %LEL / 0 – 5 Vol.-% CO26851880
IR Ex ES0 – 100 Vol.-% CH4 / 0 – 100 %LEL6851881
IR CO2 ES0 – 5 Vol.-% CO2 / 0 – 100 Vol.-% CH46851882
Dual IR Ex/CO2 HC0 – 100 % LEL / 0 – 100 Vol.-% CO26800276
CatEx SR0 – 100 % LEL or 0 – 100 Vol.-% CH46851900
CatEx 125 PR0 – 100 % LEL or 0 – 100 Vol.-% CH46812950
CatEx 125 PR Gas0 – 100 % LEL or 0 – 100 Vol.-% CH46813080
CatEx H2 1000 – 100 %LEL H2 / 0 – 100 Vol.-% H2 / 0 – 40,000 ppm H23729050
CO LC0 – 2000 ppm6813210
H2S LC0 – 200 ppm6811525
O20 – 25 Vol.%6810881
O2 1000 – 100 Vol.%6812385
O2 PR0 – 30 Vol.%6800530
Cl20 – 20 ppm6810890
CO HC0 – 10000 ppm6812010
CO20 – 5 Vol.%6810889
H20 – 2000 ppm6812370
H2 HC0 – 4 Vol.%6812025
H2S HC0 – 1000 ppm6812015
HCN0 – 50 ppm6810887
HCN PC0 – 50 ppm6813165
NH30 – 300 ppm6810888
NO0 – 200 ppm6811545
NO20 – 50 ppm6810884
NO2 LC0 – 50 ppm6812600
OV0 – 200 ppm6811530
OV-A0 – 200 ppm6811535
PH30 – 20 ppm6810886
PH3 HC0 – 2000 ppm6812020
SO20 – 100 ppm6810885
Odorant0 – 40 ppm6812535
Amine0 – 100 ppm6812545
Phosgene0 – 10 ppm6812005
Ozone0 – 10 ppm6811540
CO H2-CP0 – 2000 ppm CO6811950
O2 / CO LC0 – 2000 ppm CO / 0 – 25 Vol.-%6813275
O2 / H2S LC0 – 100 ppm H2S / 0 – 25 Vol.-%6814137
H2S LC / CO LC0 – 2000 ppm CO / 0 – 100 ppm H2S6813280
H2O20 – 20 ppm6809170
HF/HCl0 – 30 ppm6809140
Hydrazine0 – 3 ppm6809190
CO0 – 2000 ppm6809105
H2S 1000 – 100 ppm6809110
H2S HC0 – 1000 ppm6809180
O2-LS0 – 25 Vol.%6809130
NO0 – 200 ppm6809125
SO20 – 100 ppm6809160
NO20 – 50 ppm6809155
COCl20 – 10 ppm6808582
NH30 – 300 ppm6809145
HCN0 – 50 ppm6809150
Cl20 – 20 ppm6809165
Hydride0 – 20 ppm6809135
OV0 – 200 ppm6809115
H20 – 2000 ppm6809185
H2 HC0 – 4 Vol.%6811365
Part Number Description
Detective Net
C01360-1 Detective NET 433MHz (with 0.7M of cable)
Detective Plus Non-pumped
DP-AAAGCNCS-D001-A4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), non-pumped, standard battery with rigid legs, English ATEX
DP-AAAGCNCS-F001-A4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), non-pumped, extended battery with rigid legs, English ATEX
DP-AAAGCNCS-D001-C4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), non-pumped, standard battery with folding legs, English ATEX
DP-AAAGCNCS-F001-C4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), non-pumped, extended battery with folding legs, English ATEX
DP-AACNCSAG-E002-C4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), non-pumped, extended battery with folding legs, USA UL
DP-AACNAJCH-E002-A4 gas – CH4 % LEL, H2S, SO2, VO, non-pumped, extended battery with rigid legs, USA UL
DP-BUAGCNCS-F007-A4 gas – PROP % LEL, O2, H2S, CO (H2 filtered), non-pumped, extended battery with rigid legs, DUTCH ATEX
DP-AAAGCNZZ-D001-A3 gas – CH4 % LEL, O2, H2S, non-pumped, standard battery with rigid legs, English ATEX
DP-AAAGCNZZ-F001-A3 gas – CH4 % LEL, O2, H2S, non-pumped, extended battery with rigid legs, English ATEX
DP-AAAGCNZZ-D003-A3 gas – CH4 % LEL, O2, H2S, non-pumped, standard battery with rigid legs, French ATEX
DP-AAAGCSZZ-D001-A3 gas – CH4 % LEL, O2, CO (H2 filtered), non-pumped, standard battery with rigid legs, English ATEX
DP-AAAGCNCS-E002-A4 gas – CH4 % LEL, O2, CO (H2 filtered), H2S, non-pumped, extended battery with rigid legs, USA UL
DP-AAAGZZZZ-D001-A2 gas – CH4 % LEL, O2, non-pumped, standard battery with rigid legs, English ATEX
DP-AACNZZZZ-D001-A2 gas – CH4 % LEL, H2S, non-pumped, standard battery with rigid legs, English ATEX
DP-ADAGZZZZ-D001-A2 gas – BUT % LEL, O2, non-pumped, standard battery with rigid legs, English ATEX
DP-AACNZZZZ-F001-A2 gas – CH4 % LEL, H2S, non-pumped, extended battery with rigid legs, English ATEX
DP-AAZZZZZZ-D001-A1 gas – CH4 % LEL, non-pumped, standard battery with rigid legs, English ATEX
DP-AAZZZZZZ-F001-A1 gas – CH4 % LEL, non-pumped, extended battery with rigid legs, English ATEX
DP-ADZZZZZZ-D001-A1 gas – BUT % LEL, non-pumped, standard battery with rigid legs, English ATEX
DP-CNZZZZZZ-D001-C1 gas – H2S, non-pumped, standard battery with folding legs, English ATEX
Detective Plus Pumped
DP-AACNCSAG-D001-B4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), pumped, standard battery with rigid legs, English ATEX
DP-AAAGCNCS-F001-B4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), pumped, extended battery with rigid legs, English ATEX
DP-AAAGCNCS-F001-D4 gas – CH4 % LEL, O2, H2S, CO (H2 filtered), pumped, extended battery with folding legs, English ATEX
DP-AACNAGZZ-D001-B3 gas – CH4 % LEL, O2, H2S, pumped, standard battery with rigid legs, English ATEX
DP-AACNAJZZ-D001-D3 gas – CH4 % LEL, H2S, SO2, pumped, standard battery with folding legs, English ATEX
DP-ADCNCHZZ-F001-B3 gas – BUT % LEL, H2S, VO, pumped, extended battery with rigid legs, English ATEX
DP-AAAGZZZZ-F001-B2 gas – CH4 % LEL, O2, pumped, extended battery with rigid legs, English ATEX
DP-ADCHZZZZ-F001-B2 gas – BUT % LEL, VO, pumped, extended battery with rigid legs, English ATEX
DP-ACAGCNCS-D001-B4 gas – PENT % LEL, O2, H2S, CO (H2 filtered), pumped, standard battery with rigid legs, English ATEX
Detective Plus IR Non-pumped
DP-BJAGZZZZ-D019-A2 gas – Flam IR CH4 % LEL, O2, non-pumped, standard battery with rigid legs, French ATEX
DP-BJAGCNCS-E056-A4 gas – Flam IR CH4 % LEL, O2, H2S, CO (H2 filtered), non-pumped, extended battery with rigid legs, USA UL
DP-BJCNCSAG-E056-B4 gas – Flam IR CH4 % LEL, O2, H2S, CO (H2 filtered), pumped, extended battery with folding legs, USA UL
DP-BJZZZZZZ-D018-A1 gas – Flam IR CH4 % LEL, non-pumped, standard battery with rigid legs, English ATEX
DP-BKAGZZZZ-D001-A2 gas – Dual Range IR CH4 % LEL & % VOL, O2, non-pumped, standard battery with rigid legs, English ATEX
Detective Plus IR Pumped
DP-BJCNCSAG-D001-B4 gas – Flam IR CH4 0-100% LEL, O2, H2S, CO (H2 filtered), pumped, standard battery with rigid legs, English ATEX
DP-BKAGCNZZ-D001-B3 gas – Dual Range IR CH4 % LEL & % VOL, O2, H2S, pumped, standard battery with rigid legs, English ATEX
Detective Plus Sensor Modules
CH4DP0-100% LEL Methane
C3H8DP0-100% LEL Propane
C5H12DP0-100% LEL Pentane
C4H10DP0-100% LEL Butane
C2H4DP0-100% LEL Ethylene
H2DP0-100% LEL Hydrogen
FLAMDPUSA0-100% LEL Flammable Gas (USA alarms UL approval specify calibration)
FLAMDPAUS0-100% LEL Flammable Gas (AUS alarms specify calibration)
CH4DPDRLEL0-100% LEL Methane for dual range %LEL/%VOL units
CH4DPDRVOL0-100% Vol. Methane for dual range %LEL/%VOL units
O2DP0-25% Oxygen – 2 year sensor
H2SDP0-50ppm Hydrogen Sulphide
H2SDPUSA0-50ppm Hydrogen Sulphide (US alarms, UL approval)
H2SDPAUS0-50ppm Hydrogen Sulphide (AUS alarms)
SO2DP0-10ppm Sulphur Dioxide
H2DPPPM0-2000ppm Hydrogen
NODP0-100ppm Nitric Oxide
NO2DP0-10ppm Nitrogen Dioxide
CL2DPUK0-5ppm Chlorine (UK alarm levels)
CL2DP0-5ppm Chlorine
HCLDP0-10ppm Hydrogen Chloride
HCNDP0-25ppm Hydrogen Cyanide
NH3DP0-50ppm Ammonia
NH3DP10000-1000ppm Ammonia
CLO2DP0-1ppm Chlorine Dioxide
PH3DPUK0-2ppm Phosphine (UK alarm levels)
H2SDP10000-1000ppm Hydrogen Sulphide
PH3DP0-2ppm Phosphine
ASH3DP0-1ppm Arsine
VODP0-100ppm Volatile Organics
ETODP0-10ppm Ethylene Oxide
HFDP0-10ppm Hydrogen Fluoride
F2DP0-10ppm Fluorine
H2DPEC0-4% Hydrogen Electrochemical