The Drager X-am 5100 is a portable single-gas detector for HF, HCI, H2 O2 or hydrazine. Its special design with direct gas entry guarantees fast sensor response and precise measurement data by preventing gas adsorption on the device housing. The detector is also immune to electromagnetic interference.
Examples of applications include manufacturing petrochemical products, aseptic packing, or handling rocket fuel.
| Operating Temperature | -20 to +50 °C |
|---|---|
| Ingress Protection | IP54 |
| Approvals | ATEX & IECEx |
| Data Logging | 1000 hours at one-minute intervals |
| Battery Options | Rechargeable NiMH or Alkaline |
| Size | 48 x 130 x 61 mm |
| Weight | 220-250 g |
| Part Number | Model | Measurement Range |
|---|---|---|
| 3361008 | X-am 5100 Hydrogen Chloride/Hydrogen fluoride (HCI/HF) | 0-3 ppm |
| 3361009 | X-am 5100 Hydrogen Peroxide (H2O2) | 0-20 ppm |
| 3361010 | X-am 5100 Hydrazine (N2H4) | 0-3 ppm |
Warranty: 12 months, calibration 6 months
| Part Number | Sensor Type |
|---|---|
| 6809140 | HCl/HF |
| 6809170 | H2O2 |
| 6809190 | N2H4 |
| Dimensions (W × H × D) | 130 x 48 x 44 mm (5.12 x 1.89 x 1.73 in) |
|---|---|
| Weight | Typically 220 to 250 g (7.76 to 8.82 oz), depending on sensor equipment |
| Housing | Robust 2-component housing |
| Display | Matrix display with high resolution |
| Ambient Conditions | |
| Temperature |
-20 to +50 °C (-4 to 122 °F) (Measurement and storage) -40 to +50 °C (-40 to 122 °F) (Use in potentially explosive atmospheres) |
| Pressure |
700 to 1300 mbar (Measurement) 800 to 1100 mbar (Use in potentially explosive atmospheres) |
| Relative Humidity |
10 to 95 % r.h. 5 to 95 % r.h. short term |
| Protection Class | IP68 |
| Alarms | |
| Visual |
3 LED "red" (gas alarms) 3 LED "yellow" (device alarm) |
| Audible | Multi-tone > 90 dB at 30 cm (12 in) |
| Vibration | Yes |
| Additional Technical Specifications | |
| Energy Supply | NiMH battery (no dangerous goods: UN marking required during transport), replaceable by user, rechargeable |
| Bluetooth | Bluetooth 5.0 (disabled for some countries outside the EU and outside North America, but can be retrofitted. Contact Drager Service). |
| Operating Times |
Approx. 12 h (Bluetooth active) Approx. typical 100 h without Ex-sensor |
| Charging Time | < 4 h |
| Ready for Measurement | < 60 s after switch-on |
| Data Logger | Application of an optimised data compression method with high accuracy and large storage capacity. (Typically data compression >90% compared to the traditional data logger concept with adjustable interval) |
| Approvals | |
| ATEX |
I M1 Ex da ia I Ma II 1G Ex da ia IIC T4 Ga (usable in Ex-Zone 0) |
| IECEx |
Ex da ia I Ma Ex da ia IIC T4 Ga (usable in Ex-Zone 0) |
| CSA (USA & Canada) |
CSA approval: cCSAus Class I, Zone 0, AEx da ia IIC T4 Ga Class I, Div 1, Groups A, B, C, D Class II, Div 1, Gr. E, F, G |
| EAC | Contact Drager for availability |
| Directives |
2014/34/EU (ATEX) 2014/53/EU (RED) 2011/65/EU (RoHS) |
| Manufacturer's Warranty |
5 years for the XXS O2, XXS CO, and XXS H2S sensors 4 years for the device (electronics and housing) 3 years for the CatEx SR and XXS O2 PR sensor (except NO2 (2 years) and SO2 (2 years)) 2 years for the battery pack |
Get in touch with us to see how we can help you with your project