The SharpEye 40/40D-M Multi Infrared QuadSense Flame Detector uses four infrared (IR) sensors to deliver fast, reliable flame detection while effectively distinguishing real fires from non-flame background radiation. It is designed to detect both hydrogen and hydrocarbon fires over long distances with excellent false alarm immunity.
| Model Number | Description |
|---|---|
| 40/40D-M-6-31-AB-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AB-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-AB-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AB-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AB-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-AB-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AC-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AC-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-AC-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AC-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AC-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-AC-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AF-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AF-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-AF-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AF-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AF-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-AF-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AK-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AK-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-AK-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AK-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AK-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-AK-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AP-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AP-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-AP-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AP-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AP-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-AP-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AR-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AR-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-AR-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-AR-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-AR-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-AR-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| Model Number | Description |
|---|---|
| 40/40D-M-6-31-SB-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SB-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / With SBS plastic Protective cover |
| 40/40D-M-6-31-SB-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SB-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SB-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / With SBS plastic Protective cover |
| 40/40D-M-6-31-SB-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SC-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SC-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-SC-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SC-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SC-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-SC-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SF-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SF-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-SF-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SF-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SF-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-31-SF-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C,D tilt mount / Stainless steel Protective cover |
| 40/40D-M-6-31-SK-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SK-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-SK-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SK-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SK-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-SK-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SP-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SP-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-SP-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SP-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SP-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-SP-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SR-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SR-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-SR-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-31-SR-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-31-SR-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-31-SR-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| Part Number | Description |
|---|---|
| 40/40D-M-6-32-AB-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AB-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-32-AB-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AB-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AB-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-32-AB-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AC-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AC-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-32-AC-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AC-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AC-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-32-AC-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AF-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AF-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-32-AF-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AF-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AF-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C,D tilt mount / With ABS plastic Protective cover |
| 40/40D-M-6-32-AF-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AK-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AK-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-32-AK-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AK-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AK-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-32-AK-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AP-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AP-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-32-AP-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AP-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AP-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-32-AP-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AR-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AR-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-32-AR-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With Stainless steel Protective cover |
| 40/40D-M-6-32-AR-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-AR-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C,D tilt mount / With ARS plastic Protective cover |
| 40/40D-M-6-32-AR-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C,D tilt mount / With Stainless steel Protective cover |
| Model Number | Description |
|---|---|
| 40/40D-M-6-32-SB-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / INMETRO / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SB-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / INMETRO / Without 40/40C,D tilt mount / With SBS Plastic Protective cover |
| 40/40D-M-6-32-SB-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / INMETRO / Without 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SB-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / INMETRO / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SB-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / INMETRO / With 40/40C,D tilt mount / With SBS Plastic Protective cover |
| 40/40D-M-6-32-SB-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / INMETRO / With 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SC-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SC-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS Plastic Protective cover |
| 40/40D-M-6-32-SC-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SC-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SC-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS Plastic Protective cover |
| 40/40D-M-6-32-SC-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SF-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SF-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With ABS Plastic Protective cover |
| 40/40D-M-6-32-SF-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / FM, FMC, CSA US-C / Without 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SF-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / FM, FMC, CSA US-C / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SF-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / FM, FMC, CSA US-C / With 40/40C,D tilt mount / With ABS Plastic Protective cover |
| 40/40D-M-6-32-SF-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / FM, FMC, CSA US-C / With 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SK-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SK-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS Plastic Protective cover |
| 40/40D-M-6-32-SK-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SK-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SK-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS Plastic Protective cover |
| 40/40D-M-6-32-SK-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SP-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / Korea / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SP-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / Korea / Without 40/40C,D tilt mount / With ARS Plastic Protective cover |
| 40/40D-M-6-32-SP-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / Korea / Without 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SP-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / Korea / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SP-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / Korea / With 40/40C,D tilt mount / With ARS Plastic Protective cover |
| 40/40D-M-6-32-SP-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / Korea / With 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SR-N-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SR-N-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Russia / Without 40/40C,D tilt mount / With ARS Plastic Protective cover |
| 40/40D-M-6-32-SR-N-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Russia / Without 40/40C,D tilt mount / With Stainless Steel Protective cover |
| 40/40D-M-6-32-SR-Y-0 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Russia / With 40/40C,D tilt mount / Without Protective cover |
| 40/40D-M-6-32-SR-Y-7 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Russia / With 40/40C,D tilt mount / With ARS Plastic Protective cover |
| 40/40D-M-6-32-SR-Y-8 | SharpEye 40/40 IR3 + Hydrogen Flame Detector / Universal wiring / -60°C to +85°C / 3/4″ NPT / Stainless Steel / EAC Russia / With 40/40C,D tilt mount / With Stainless Steel Protective cover |
| Part Number | Description |
|---|---|
| 877090 | 40/40C, D Tilt Mount |
| 789260-1 | 40/40C, D Pole Mount 3″ |
| 789260-2 | 40/40C, D Pole Mount 2″ |
| 789260-3 | 40/40C, D Pole Mount 4″ |
| 877670 | 40/40C, D Duct Mount |
| 877163 | 40/40C, D Protective Cover – Stainless Steel |
| 877263 | 40/40C, D Protective Cover – ABS Plastic |
| 877650 | 40/40C, D Air Shield |
| 877563 | 40/40C, D Cone of View Limiter |
| 877060 | 40/40C, D Cone Viewer (Laser Aimer Excluded) |
| 794079 | USB/RS485 Converter Kit |
| 888810 | HART Hand-held Diagnostics Kit |
At highest sensitivity setting for 1 ft² (0.1 m²) pan fire.
| Fuel | Range (ft/m) |
|---|---|
| Gasoline | 300 / 90 |
| n-Heptane | 300 / 90 |
| Diesel Fuel | 210 / 63 |
| JP5 | 210 / 63 |
| Kerosene | 210 / 63 |
| Ethanol 95% | 183 / 55 |
| Isopropyl Alcohol (IPA) | 183 / 55 |
| Methanol | 183 / 55 |
| Methane(1) | 210 / 63 |
| Liquefied Petroleum Gas (LPG)(1) | 210 / 63 |
| Polypropylene Pellets | 163 / 49 |
| Office Paper | 114 / 34 |
| Hydrogen(1) | 166 / 50 |
| Magnesium Alloy | N/A |
| Gun Powder (1.5 in² [10 cm²]) | 200 / 60 |
| Fireworks (10 pieces per test) | 33 / 10 |
| Cooking Oil | 210 / 63 |
| Mineral Oil (20W50) | 210 / 63 |
| Wood | 114 / 34 |
| Ethylene Glycol | 166 / 50 |
| Butyl Acrylate | 250 / 75 |
| Vinyl Acetate | 250 / 75 |
| Flammable Adhesive (Flash Point < 140°F [60°C]) | 210 / 63 |
| Solvents | 250 / 75 |
| Oil Paint | 210 / 63 |
| Jet A1 | 210 / 63 |
| Battery(2) | 283 / 85 |
| Spectral Response | Four infrared (IR) bands between 2 μm and 5 μm |
|---|---|
| Detection Response Time |
Standard Response: Typically < 2 sec at 131 ft (40 m) and 10 sec at 300 ft (90 m) Ultra Fast Response: Typically < 1 sec at 100 ft (30 m) High Speed Response (Explosion): 50 msec for 1 ft (0.3 m) diameter sphere liquefied petroleum gas (LPG)/air mixture explosion at 66 ft (20 m) via analog voltage output. |
| Sensitivity Ranges | 6 sensitivity ranges |
| Field of View |
Hydrogen: Horizontal – 90°, Vertical – 90° Other fuels: Horizontal – 80°, Vertical – 80° |
| Coverage Area | 12,999 ft³ (3962 m³) |
| Temperature Range |
Operating: -76 to +185°F (-60 to +85°C) Storage: -76 to +185°F (-60 to +85°C) |
| Humidity | Non-condensing relative humidity up to 100% |
| Operating Voltage | 24 Vdc nominal (18–32 Vdc) |
|---|---|
| Cable Entries | 2 × ¾-in. – 14 NPT conduits or 2 × M25 × 1.5 mm ISO |
| Electrical Input Protection | According to EN 50130 |
| Electromagnetic Compatibility | EMI/RFI protected to EN61000-6-3 and EN 50130 |
| Electrical Interface | The detector includes 17 terminals and one wiring option |
| Relays | Alarm, Fault, and Auxiliary SPST volt-free contacts rated 2 A at 30 VDC |
|---|---|
| Analog Output Default(1) |
Analog port malfunction: 0 V (<0.5 V) Normal: 2 V ± 0.3 V Alarm/Explosion: 5 V ± 0.3 V |
| 0–20 mA (Stepped) Default(1) |
Fault: 0 ± 1 mA Built-in Test (BIT) Fault: 2 mA ± 0.3 mA Normal: 4 mA ± 0.3 mA Warning: 16 mA ± 0.3 mA Alarm: 20 mA ± 0.3 mA |
| HART® Protocol | HART communication on the 0–20 analog current (FSK) used for maintenance, configuration changes, and asset management, available in mA source output wiring options. |
| RS-485 | RS-485 Modbus® compatible communication link for computer-controlled installations. |
| Enclosure Options |
Electropolished Stainless Steel 316 Heavy-duty copper-free aluminum (less than 1%), polyurethane painted |
|---|---|
| Mounting | Electropolished Stainless Steel 316 |
| Dimensions | Detector: 4 × 4.6 × 6.18 in (100.6 × 117 × 155 mm) |
| Weight |
Detector (Stainless Steel): 6.3 lb (2.9 kg) Detector (Aluminum): 2.8 lb (1.3 kg) Tilt Mount: 2.5 lb (1.1 kg) |
| Environmental Standards | DNV 2-4 |
| Water & Dust Protection | IP66 and IP68 per EN60529 NEMA® 250 6P |
Get in touch with us to see how we can help you with your project