Spectrex SharpEye 40/40D-I IR QuadSense Flame Detector

  1. Home
  2. Products

SharpEye 40/40D-I Multi-Spectrum QuadSense Flame Detector

The SharpEye 40/40D-I Multi-Spectrum QuadSense Flame Detector uses four infrared (IR) sensors to provide fast and reliable flame detection while effectively distinguishing real fires from non-flame background radiation. It is designed for long-range hydrocarbon fire detection with outstanding false alarm immunity.

Features & Benefits

  • Four infrared (IR) sensors for enhanced flame detection.
  • Detects hydrocarbon fuel and gas fires up to 300 ft (90 m).
  • Extended detection range for greater coverage.
  • Ultra-fast response time of less than 50 milliseconds.
  • Excellent false alarm immunity.
  • High reliability with 150,000-hour MTBF.
  • Operating temperature range from -60°C to +85°C.
  • Five-year warranty.
  • Six selectable sensitivity levels.
  • Smart field of view integrity monitoring.
  • Built-in infrared self-test.
  • Multiple output options for easy integration.
  • Factory calibrated for plug-and-play installation.
  • Universal wiring option.
  • Two-mode heated optics for harsh environments.
  • Worldwide hazardous area certifications.
  • SIL3 compatible.
  • Internal event log recorder.

Applications

  • Oil and gas onshore and offshore facilities.
  • Pipelines.
  • Chemical and petrochemical plants.
  • Storage tank farms.
  • Fuel and gas processing and storage facilities.
  • Power generation plants.
  • Explosives and munitions facilities.
  • Fertilizer plants.
  • Automotive industry.
  • Vehicle battery charging stations.
  • Hydroxyl production and storage.
  • Aerospace industry.
  • Waste management facilities.
  • Pharmaceutical industry.
  • Printing facilities.
  • Warehouses.
  • Hazardous material storage areas.
  • Food processing plants.

Order Information

M25 / Aluminium

Part Number Description
40/40D-I-6-31-AB-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AB-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-AB-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AB-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AB-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-AB-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AC-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AC-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-AC-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AC-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AC-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-AC-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AF-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-31-AF-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-AF-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AF-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-31-AF-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-AF-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AK-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AK-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-AK-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AK-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AK-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-AK-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AP-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AP-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-AP-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AP-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AP-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-AP-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AR-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AR-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-AR-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-AR-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-AR-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-AR-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Aluminium / EAC Russia / With 40/40C,D tilt mount / With Stainless steel Protective cover

Order Information

M25 / Stainless Steel

Part Number Description
40/40D-I-6-31-SB-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SB-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / With SBS plastic Protective cover
40/40D-I-6-31-SB-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SB-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SB-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / With SBS plastic Protective cover
40/40D-I-6-31-SB-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SC-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SC-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-SC-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SC-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SC-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-SC-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SF-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-31-SF-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-SF-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SF-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-31-SF-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-31-SF-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SK-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SK-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-SK-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SK-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SK-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-SK-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Kazakhstan / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SP-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SP-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-SP-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SP-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SP-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-SP-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SR-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SR-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-SR-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-31-SR-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-31-SR-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-31-SR-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / M25 / Stainless steel / EAC Russia / With 40/40C,D tilt mount / With Stainless steel Protective cover
Part Number Description
40/40D-I-6-32-AB-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-AB-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-AB-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AB-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-AB-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-AB-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / INMETRO / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AC-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-AC-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-AC-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AC-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-AC-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-AC-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / ATEX / IECEx / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AF-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-AF-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-AF-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AF-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-AF-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-AF-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AK-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-AK-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-AK-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AK-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-AK-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-AK-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Kazakhstan / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AP-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-AP-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-AP-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AP-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-AP-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-AP-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / Korea / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AR-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-AR-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-AR-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-AR-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-AR-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-AR-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Aluminium / EAC Russia / With 40/40C, D tilt mount / With Stainless steel Protective cover

3/4″ NPT / Stainless Steel

Order Code Description
40/40D-I-6-32-SB-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SB-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / Without 40/40C, D tilt mount / With SBS plastic Protective cover
40/40D-I-6-32-SB-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SB-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SB-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / With 40/40C, D tilt mount / With SBS plastic Protective cover
40/40D-I-6-32-SB-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / INMETRO / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SC-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-SC-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-SC-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / Without 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SC-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / Without Protective cover
40/40D-I-6-32-SC-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-SC-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / ATEX / IECex / EN-54-10 / With 40/40C,D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SF-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SF-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-SF-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SF-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SF-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With ABS plastic Protective cover
40/40D-I-6-32-SF-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / FM, FMC, CSA US-C / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SK-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SK-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-SK-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SK-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SK-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-SK-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Kazakhstan / With 40/40C, D tilt mount / Stainless steel Protective cover
40/40D-I-6-32-SP-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SP-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-SP-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SP-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SP-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-SP-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / Korea / With 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SR-N-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / Without 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SR-N-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / Without 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-SR-N-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / Without 40/40C, D tilt mount / With Stainless steel Protective cover
40/40D-I-6-32-SR-Y-0SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / With 40/40C, D tilt mount / Without Protective cover
40/40D-I-6-32-SR-Y-7SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / With 40/40C, D tilt mount / With ARS plastic Protective cover
40/40D-I-6-32-SR-Y-8SharpEye 40/40 Triple IR Flame Detector / Universal wiring / -60C to + 85C / 3/4″ NPT / Stainless steel / EAC Russia / With 40/40C, D tilt mount / Stainless steel Protective cover

Accessories

Order Code Description
877090 40/40C, D tilt mount
789260-1 40/40C, D pole mount 3″
789260-2 40/40C, D pole mount 2″
789260-3 40/40C, D pole mount 4″
877670 40/40C, D duct mount
877163 40/40C, D protective cover – Stainless steel
877263 40/40C, D protective cover – ABS plastic
877650 40/40C, D air shield
877563 40/40C, D Cone of view limiter
877060 40/40C, D Cone viewer (laser aimer excluded)
794079 USB/RS485 converter kit
888810 HART hand-held diagnostics kit

Detection Ranges

At Highest Sensitivity Setting for 1 ft² (0.1 m²) Pan Fire
Fuel Range (ft / m)
Gasoline300 / 90
n-Heptane300 / 90
Diesel Fuel210 / 63
JP5210 / 63
Kerosene210 / 63
Ethanol 95%183 / 55
Isopropyl Alcohol (IPA)183 / 55
Methanol183 / 55
Methane (1)210 / 63
Liquefied Petroleum Gas (LPG) (1)210 / 63
Polypropylene Pellets163 / 49
Office Paper114 / 34
Hydrogen (1)N/A
Magnesium AlloyN/A
Gun Powder (1.5 in² [10 cm²])200 / 60
Fireworks (10 pieces per test)33 / 10
Cooking Oil210 / 63
Mineral Oil (20W50)210 / 63
Wood114 / 34
Ethylene Glycol166 / 50
Butyl Acrylate250 / 75
Vinyl Acetate250 / 75
Flammable Adhesive (Flash Point < 140°F [60°C])210 / 63
Solvents250 / 75
Oil Paint210 / 63
Jet A1210 / 63
Battery (2)283 / 85

General Specifications

Specification Details
Spectral Response Four infrared (IR) bands between 4 μm and 5 μm
Detection Response Time Standard: Typically < 2 sec at 131 ft (40 m), 10 sec at 300 ft (90 m)
Ultra Fast: Typically < 1 sec at 100 ft (30 m)
High Speed (Explosion): 50 msec for 1 ft (0.3 m) LPG/air sphere explosion at 66 ft (20 m) via analog voltage output
Sensitivity Ranges 6 sensitivity ranges
Field of View Horizontal: 100°
Vertical: 95°
Coverage Area 12,999 ft³ (3962 m³)
Temperature Range Operating: -76 to +185°F (-60 to +85°C)
Storage: -76 to +185°F (-60 to +85°C)
Humidity Non-condensing relative humidity up to 100%

Electrical Specifications

Specification Details
Operating Voltage 24 Vdc nominal (18–32 Vdc)
Cable Entries 2 × ¾-in. – 14 NPT conduits or 2 × M25 × 1.5 mm ISO
Electrical Input Protection According to EN 50130
Electromagnetic Compatibility EMI/RFI protected to EN61000-6-3 and EN 50130
Electrical Interface The detector includes 17 terminals and one wiring option

Outputs

Output Details
Relays Alarm, fault and auxiliary SPST volt-free contacts rated 2 A at 30 VDC
Analog Output (Default) Malfunction: 0 V (<0.5 V)
Normal: 2 V ± 0.3 V
Alarm / Explosion: 5 V ± 0.3 V
0–20 mA (Stepped) Fault: 0 ± 1 mA
BIT Fault: 2 mA ± 0.3 mA
Normal: 4 mA ± 0.3 mA
Warning: 16 mA ± 0.3 mA
Alarm: 20 mA ± 0.3 mA
HART® Protocol HART communication on the 0–20 mA analog current (FSK) for maintenance, configuration, and asset management.
RS-485 Modbus® compatible communication for computer-controlled installations.

Mechanical Specifications

Specification Details
Enclosure Options Electropolished Stainless Steel 316
Heavy-duty Copper-free Aluminum (<1%), Polyurethane painted
Mounting Electropolished Stainless Steel 316
Dimensions Detector: 4 × 4.6 × 6.18 in (100.6 × 117 × 155 mm)
Weight Stainless Steel Detector: 6.3 lb (2.9 kg)
Aluminum Detector: 2.8 lb (1.3 kg)
Tilt Mount: 2.5 lb (1.1 kg)
Environmental Standards DNV 2-4
Water & Dust Protection IP66 & IP68 (EN60529), NEMA® 250 Type 6P

Enquire About This Product

Get in touch with us to see how we can help you with your project

Thank you Message Sent
Error occurred while sending email. Please try again later.