The Dräger Flame 1500 is a triple infrared (IR3) flame detector designed to provide fast and reliable detection of hydrocarbon fires over long distances. It delivers excellent immunity to false alarms and is FM approved for use in demanding industrial environments.

Features

  • Triple infrared (IR3) flame detection technology.
  • Designed for hydrocarbon fire detection.
  • Long-range flame detection.
  • Excellent immunity to false alarms.
  • FM approved.
  • SIL2 compliant to IEC 61508.
  • HART communication interface.
  • Low power consumption.
  • Heated viewing window to prevent icing and condensation.
  • Automatic Optical Verification Test (OVT).
  • No reflective target required for optical verification.
  • Tri-colour LED status indicator.
  • Available in aluminium and stainless steel housings.

Benefits

  • Fast and reliable hydrocarbon flame detection.
  • Excellent resistance to false alarms from welding and hot surfaces.
  • Automatic monitoring of optics and electronics.
  • Reliable operation in harsh weather conditions.
  • Easy installation and maintenance.

Status Indicators

  • Green LED – Normal operation.
  • Yellow LED – Fault condition.
  • Red LED – Fire alarm.

Order Information

  • 3721519 – Dräger Flame 1500, Aluminium, 2 × M25.
  • 3721517 – Dräger Flame 1500, Aluminium, 2 × 3/4" NPT.
  • 3721518 – Dräger Flame 1500, Stainless Steel, 2 × M25.
  • 3721516 – Dräger Flame 1500, Stainless Steel, 2 × 3/4" NPT.

Accessories

  • 4209307 – Dräger FS-5000 Flame Simulator.
  • 3718732 – Standard Mounting Bracket (316 Stainless Steel).
  • 3701298 – Marine Mounting Bracket (316 Stainless Steel).
  • 3701303 – Detector Sealing Kit (Metric).
  • 3701299 – Sunshield.
  • 3701300 – 2" Pole Mount Kit.
  • 3701301 – 3" Pole Mount Kit.
  • 3701302 – 4" Pole Mount Kit.

Detector Characteristics

Parameter Specification
Model Dräger Flame 1500
Type Explosion-proof multi-spectrum (triple) IR flame detector
Spectral Range Three wavelengths in the range from 3 μm to 8 μm
Field of View Horizontal: 90°
Vertical: 90°
Response Time 4 seconds (typical)
Sensitivity Settings Low: 15 m
Medium: 30 m (Standard)
High: 60 m

Detection Range

Fuel Range
n-Heptane / Gasoline 60 m (200 ft)
Methanol 42 m (136 ft)
Methane 50 m (165 ft)

Note: Detection range based on a 0.1 m² (1 ft²) fire pan or a 0.6 m (3 ft) flaring fire.

Electrical Specifications

Parameter Specification
Relay Outputs Alarm and Fault
Signal Output 0–20 mA
Communication RS485, HART® 7
Supply Voltage 24 VDC nominal (18–32 VDC)
Power Consumption Minimum 3 W / Maximum 12 W with heating

Mechanical Specifications

Parameter Specification
Housing Material Aluminium or Stainless Steel, powder-coated
Cable Entry Dual M25 or ¾″ NPT
Weight Aluminium: 2.5 kg (5.5 lbs)
Stainless Steel: 6 kg (13.2 lbs)
Protection Rating IP66, NEMA 4X

Environmental Conditions

Parameter Specification
Operating Temperature -60°C to +85°C (-76°F to +185°F)

Approvals & Certifications

Certification Approval
ATEX Ex II 2 G Ex db IIC T4 Gb IP66
IECEx Ex II 2 G Ex db IIC T4 Gb IP66
FM/FMC Class 1 Zone 1 AEx db IIC T4
Class 1 Div. 1, Groups B, C, D T4
EAC TR CU Requested
CCCF Requested
INMETRO / PESO Available on request
Functional Safety SIL2 Certified