The Oldham OLCT 10N by Teledyne is designed to detect combustible, toxic gases or oxygen.
Intended for use in combination with the MX 32 and MX 43 controller, the OLCT 10N provides a fast and accurate response.
The controller receives all transmitter information in less than 1 second.
The non-intrusive operator interface requires only a simple magnetic wand and allows one-person calibration without opening the enclosure.
OLCT 10N Detectors – ATEX and IECEx Approved II 3 G
OLCT10N-001 – Digital transmitter without display, ATEX 3G, IP65, 0-100% LEL CH4 (5% vol).
OLCT10N-002 – Digital transmitter without display, ATEX 3G, IP65, 0-100% LEL CH4 (4.4% vol).
OLCT10N-003 – Digital transmitter without display, ATEX 3G, IP65, 0-100% LEL H2.
OLCT10N-004 – Digital transmitter without display, ATEX 3G, IP65, 0-100% LEL C4H10 (Butane).
OLCT10N-005 – Digital transmitter without display, ATEX 3G, IP65, 0-100% LEL C3H8 (Propane).
OLCT10N-200 – Digital transmitter without display, ATEX 3G, IP65, 0-30% vol O2, sensor lifetime 2 years.
OLCT10N-272 – Digital transmitter without display, ATEX 3G, IP65, 0-30% vol O2, sensor lifetime 5 years.
OLCT10N-204 – Digital transmitter without display, ATEX 3G, IP65, 0-300 ppm CO.
OLCT10N-205 – Digital transmitter without display, ATEX 3G, IP65, 0-1000 ppm CO.
OLCT10N-213 – Digital transmitter without display, ATEX 3G, IP65, 0-30 ppm H2S.
OLCT10N-214 – Digital transmitter without display, ATEX 3G, IP65, 0-100 ppm H2S.
OLCT10N-216 – Digital transmitter without display, ATEX 3G, IP65, 0-100 ppm NO.
OLCT10N-217 – Digital transmitter without display, ATEX 3G, IP65, 0-300 ppm NO.
OLCT10N-219 – Digital transmitter without display, ATEX 3G, IP65, 0-10 ppm NO2.
OLCT10N-220 – Digital transmitter without display, ATEX 3G, IP65, 0-30 ppm NO2.
OLCT10N-231 – Digital transmitter without display, ATEX 3G, IP65, 0-100 ppm NH3.
OLCT10N-232 – Digital transmitter without display, ATEX 3G, IP65, 0-1000 ppm NH3.
OLCT10N-252 – Digital transmitter without display, IP65, 0-5000 ppm CO2 for use in non-hazardous areas only.
OLCT10N-239 – Digital transmitter without display, IP65, 0-5% vol CO2 for use in non-hazardous areas only.
OLCT10N-241 – Digital transmitter without display, IP65, 0-100% vol CO2 for use in non-hazardous areas only.
Catalytic – Poison Resistant Versions
OLCT10N-AP-001 – OLCT10N CH4, Methane 0-100% LEL (5% vol), poison-resistant sensor.
OLCT10N-AP-002 – OLCT10N CH4, Methane 0-100% LEL (4.4% vol), poison-resistant sensor.
OLCT10N-AP-005 – OLCT10N C3H8, Propane 0-100% LEL, poison-resistant sensor.
OLCT10N-AP-004 – OLCT10N C4H10, Butane 0-100% LEL, poison-resistant sensor.
OLCT10N-AP-003 – OLCT10N H2, Hydrogen 0-100% LEL, poison-resistant sensor.
OLCT 10N Accessories
6331163 – Calibration kit for CPS10 and OLCT 10N, including a bar and magnetic calibration cap.
6123717 – Shock-guard protector for OLC(T) 10 and 300 series detectors.
6147872 – Tool kit including one screwdriver and one flat cable for signal measurement.
OLCT 10N Replacement Sensors
6798301 – CO replacement sensor, 0-300 ppm / 0-1000 ppm, compatible with OLCT 10, OLCT 10N, and CPS10.
6113332 – NO2 replacement sensor, 0-10 ppm / 0-30 ppm, compatible with OLCT 10, OLCT 10N, and CPS10.
6113341 – H2S replacement sensor, 0-30 ppm / 0-100 ppm, for OLCT 10N.
6799345 – O2 replacement sensor, 0-30% Vol., for OLCT 10N, 2-year lifetime.
6113720 – O2 replacement sensor, 0-30% Vol., for OLCT 10N, 5-year lifetime.
6113331 – NO replacement sensor, 0-100 ppm / 0-300 ppm, compatible with OLCT 10, OLCT 10N, and CPS10.
6314118 – NH3 replacement sensor, 0-100 ppm, for OLCT 10N.
6314119 – NH3 replacement sensor, 0-1000 ppm, for OLCT 10N.
6314196 – CO2 replacement sensor, 0-5000 ppm, for OLCT 10N.
6314195 – CO2 replacement sensor, 0-5% vol, for OLCT 10N.
6314197 – CO2 replacement sensor, 0-100% vol, for OLCT 10N.
Get in touch with us to see how we can help you with your project