Oldham MX 16 One Channel Fixed Controller

  1. Home
  2. Products

Oldham MX 16 One Channel Fixed Controller

The Oldham MX 16 is a compact digital or analogue controller with one input. A low-profile controller that continuously monitors gas and processes any 4-20 mA, on/off or compatible digital signal.

Typical gas applications

    O2
    CO2
    CH4
    H2
    LPG

Specially designed for applications in laboratories, storage, small boiler room, and breweries or battery charging rooms, the MX 16 measuring unit prevents the risks of an explosion linked to the presence of toxic, anoxic and explosive gases in the ambient air.

Used with the OLCT 10N O₂ and CO₂ digital sensor series or any other O2, CO2, CH4, GPL and H2 analogue sensor, the MX 16 provides a solution that complies with French European standards.

  • Simplified configuration (no software)
  • 4-20mA input
  • Relay outputs 2 alarm + 1 fault (non-configurable)
  • Small footprint
  • Low cost, easy to install and ready to use
  • Replaces MX15 controller
  • Brand Oldham/Teledyne

Available in Easy Duo version, which includes the controller, detector and cable:

  • MX 16 + OLCT 10N O₂
  • MX 16 + OLCT 10N CO₂

MX16 Configurable Controller (via COM16)

MX16-0-0-0-0-0 – MX16 controller, Analogue or Digital input (Factory setting: CH4 0-100% LEL analogue detector)

MX16-0-0-1-0-0 – MX16 controller, Analogue or Digital input with RS485 digital output (Factory setting: CH4 0-100% LEL analogue detector)

MX16 Preconfigured Controllers (Detector Not Included)

MX16-A-3-0-0-0 – MX16 controller with one Analogue (4-20mA) input for O2 (0-30% Vol.)

MX16-A-3-1-0-0 – MX16 controller with one Analogue (4-20mA) input for O2 (0-30% Vol.) and RS485 digital output

MX16-A-4-0-0-0 – MX16 controller with one Analogue (4-20mA) input for CO2 (0-5% Vol.)

MX16-A-4-1-0-0 – MX16 controller with one Analogue (4-20mA) input for CO2 (0-5% Vol.) and RS485 digital output

MX16-A-5-0-0-0 – MX16 controller with one Analogue (4-20mA) input for CH4 (0-100% LEL)

MX16-A-5-1-0-0 – MX16 controller with one Analogue (4-20mA) input for CH4 (0-100% LEL) and RS485 digital output

MX16-A-6-0-0-0 – MX16 controller with one Analogue (4-20mA) input for LPG (0-100% LEL)

MX16-A-6-1-0-0 – MX16 controller with one Analogue (4-20mA) input for LPG (0-100% LEL) and RS485 digital output

MX16-A-7-0-0-0 – MX16 controller with one Analogue (4-20mA) input for H2 (0-100% LEL)

MX16-A-7-1-0-0 – MX16 controller with one Analogue (4-20mA) input for H2 (0-100% LEL) and RS485 digital output

EASY DUO Packs (MX16 Controller + OLCT10N Detector)

MX16-N-1-0-0-0 – MX16 controller pack with OLCT10N O2 detector (0-30% Vol., 2-year sensor life), supplied with 10m cable

MX16-N-1-1-0-0 – MX16 controller pack with OLCT10N O2 detector (0-30% Vol., 2-year sensor life), supplied with 10m cable and RS485 digital output

MX16-N-2-0-0-0 – MX16 controller pack with OLCT10N CO2 detector (0-5% Vol.), supplied with 10m cable

MX16-N-2-1-0-0 – MX16 controller pack with OLCT10N CO2 detector (0-5% Vol.), supplied with 10m cable and RS485 digital output

Accessories

WCDCOM16 – COM16 configuration software supplied with USB cable for MX16-0-x-x-x-x controllers used with O2, CO2, CH4, LPG and H2 gas detection applications