Oldham GMI BM25 Transportable Multigas Monitor
The Oldham BM25 Gas Detector is a portable area monitor capable of detecting up to five gases simultaneously, including flammable, oxygen, and toxic gases. It is ideal for temporary gas detection applications, perimeter monitoring, and locations where fixed gas detectors cannot be installed.
Pre-calibrated smart sensors can be easily replaced, allowing the BM25 to be configured for a wide range of gas monitoring requirements. Multiple units can be daisy-chained using 25m, 50m, or 100m alarm transfer kits, ensuring that if one detector alarms, all connected units activate simultaneously.
The wireless BM25 uses a 2.4 GHz mesh network, eliminating the need for cabling. Each detector automatically joins the network when powered on, enabling peer-to-peer communication, data relay, and automatic network recovery if a detector is removed or communication is interrupted.
The MX 40 controller provides wireless access to detector readings, alarm resets, and network status monitoring. The system automatically reroutes communication paths if a detector is offline, ensuring reliable operation.
Detectable Gases
- Combustible Gases
- Methane
- Propane
- Butane
- Isobutane
- LPG
- Ethanol
- Pentane
- Oxygen (O₂)
- Carbon Monoxide (CO)
- Hydrogen Sulfide (H₂S)
- Hydrogen (H₂)
- Sulfur Dioxide (SO₂)
- Chlorine (Cl₂)
- Nitrogen Dioxide (NO₂)
- Nitric Oxide (NO)
- Hydrogen Chloride (HCl)
- Hydrogen Cyanide (HCN)
- Ammonia (NH₃)
- Phosphine (PH₃)
- Arsine (AsH₃)
- Silane (SiH₄)
- Ethylene Oxide (ETO)
- Carbon Dioxide (CO₂)
- Isobutylene
- Hydrofluoric Acid (HF)
- Ozone (O₃)
- Phosgene (COCl₂)
- Chlorine Dioxide (ClO₂)
- Hydrazine (N₂H₄)
Key Features
- Standalone or networked operation.
- Backlit graphic LCD display.
- Optional pumped sampling versions.
- Infrared sensors available for specific gases.
- Wireless communication range up to 1000 m (line of sight).
- 360° visual alarm and 103 dB audible alarm.
- Stores up to four months of data.
- IP66 ingress protection.
- STEL and TWA monitoring.
- Battery runtime up to 170 hours (135 hours wireless).
- Supports up to 30 detectors on one wireless network.
- Operates even if overturned due to sensor positioning.
- Recharge time approximately 4.5 hours.
- Safe trickle charging for long-term monitoring in hazardous areas.
- ATEX, IECEx, CSA, INMETRO and EAC certified.
Dimensions and Weight
- Dimensions: 470 × 180 × 190 mm (16.7 × 7.1 × 7.5 in)
- Weight: 6.8 kg (15 lbs)
Included with Detector
- BM25 Gas Detector
- Instruction Manual
- Battery Charger with Universal Power Cord
- Calibration Adapter
- Maintenance Tool
Standard Detector Configurations
- 6514842-L12300 – ATEX, LEL Methane / CO / H₂S / O₂, no pump.
- 6514842-L12301 – ATEX, LEL Methane / CO / H₂S / O₂, with pump.
- 6514872-L12300 – CSA, LEL Methane / CO / H₂S / O₂, no pump.
- 6514872-L12301 – CSA, LEL Methane / CO / H₂S / O₂, with pump.
- 6514889-L12300 – Wireless ATEX, LEL Methane / CO / H₂S / O₂, no pump.
- 6514889-L12301 – Wireless ATEX, LEL Methane / CO / H₂S / O₂, with pump.
- 6514891-L12300 – Wireless CSA, LEL Methane / CO / H₂S / O₂, no pump.
- 6514891-L12301 – Wireless CSA, LEL Methane / CO / H₂S / O₂, with pump.
Replacement Sensors
- LEL Catalytic Bead Sensors (Methane)
- LEL Infrared Sensors for Methane, Propane, Butane, LPG, Ethanol
- Infrared CO₂ Sensors (0–5% Vol.)
- Electrochemical Sensors for CO, H₂S, NH₃, H₂, Cl₂, NO, NO₂, SO₂, HCN, HCl, HF, O₃, PH₃, AsH₃, SiH₄, ETO, Hydrazine and more.
- PID Sensor (0–1500 ppm)
Monitor
8328030 – Dräger Polytron 8900 UGLD d S, 4-20mA/HART output with 3 relays, stainless steel Ex d housing.
Accessories
4544101 – Magnetic Wand
8328021 – Remote Sensing Head with wall mount kit
Connecting Cable with Plug for Remote Sensing Head
8323305 – 5 m cable
8323315 – 15 m cable
8323330 – 30 m cable
8328042 – UGLD Calibration and Bump Test Kit without Air Cylinder
6813239 – Zero Air Gas Cylinder, 112L, for Calibration and Bump Test Kit
4544198 – Pole Mount Kit
8323405 – Dräger PolySoft Configuration Software
4544197 – IR Connection Kit (requires PolySoft)