In June 2017, MSA launched the ULTIMA X5000 as our new flagship gas detector and transmitter. This successful launch, with its expanding sensor offering and technological advances that increase safety while reducing the total cost of ownership, will serve as a direct replacement for the ULTIMA X and its derivative products (ULTIMA XE, XP, XA, XIR, TriGard, TriGas, etc.), effective December 31, 2020.

The ULTIMA X5000 was designed and intended to eventually phase out the ULTIMA X, as it mounts in the exact physical location with ease. The conduit entries, standoffs, and mounting bolts are located in the same place, allowing for installation using existing cabling.

Support of the ULTIMA X product line will continue for at least 5 years after discontinuation.

MSA’s Ultima X Series Gas Monitors are microprocessor-based transmitters engineered with the customer in mind. Utilising DuraSource Technology for extended sensor life, the monitors are available in either stainless steel or polycarbonate enclosure housings.

The HART Field Communications Protocol provides increased sensor data, part of cost-effective asset management. HART also provides convenient setup, calibration and diagnostics. Calibrate, set up or perform diagnostics with HART from any point along the 4-20 mA line. HART also allows existing component installation and wiring to be used, reducing installation costs

Ultima XE Gas Monitor

Explosion-proof, stainless steel gas detector with display

The Ultima XE Gas Monitor offers:

  • Explosion-proof 316 stainless steel
  • Multiple-entry mounting enclosure
  • Type 4X, IP66

Ultima XA Gas Monitor

Water- and corrosion-resistant, all-purpose, polycarbonate gas detector with display

  • NEMA 4X rating
  • Lightweight (only 1.5 lbs)

Ultima XIR Gas Monitor

Explosion-proof, stainless steel, infrared gas detector with display

  • DuraSource Technology for improved IR sensor life
  • 316 stainless steel
  • Multiple-entry mounting enclosure
  • Fast response time
  • Operation based on dual-wavelength, heated-optics technology, providing definitive compensation for temperature, humidity, and ageing effects
  • IR technology for excellent long-term stability, eliminating the need for frequent calibrations
  • Sintered disk-free design for optimum performance in harsh environments
  • No-gas calibration; only zero adjustment is required for full calibration
  • Type 4X, IP66 rating

Gases and Ranges

  • Acetylene IR- 0-2.5%
  • Ammonia- 0-50% LEL
  • Ammonia- 0-100 PPM
  • Ammonia- 0-1000 PPM
  • Arsine- 0-2 PPM
  • Bromine- 0-5 PPM
  • Carbon dioxide IR- 0-0.5%
  • Carbon dioxide IR- 0-2%
  • Carbon dioxide IR- 0-5%
  • Carbon monoxide- 0-100 PPM
  • Carbon monoxide- 0-500 PPM
  • Carbon monoxide- 0-1000 PPM
  • Chlorine- 0-5 PPM
  • Chlorine- 0-10 PPM
  • Chlorine- 0-20 PPM
  • Chlorine dioxide- 0-3 PPM
  • IR combustible gas – Methane- 0-100% LEL
  • IR combustible gas – Non-methane- 0-100% LEL
  • Combustible gas- 0-100% LEL natural gas and H2
  • Combustible gas- 0-100% LEL petroleum vapours
  • Combustible gas-0-100% solvents
  • Diborane- 0-50 PPM
  • Ethylene oxide- 0-10 PPM
  • Fluorine- 0-5 PPM
  • Hydrogen fluoride- 0-10 PPM
  • Hydrogen- 0-1000 PPM
  • Hydrogen chloride- 0-50 PPM
  • Hydrogen cyanide- 0-50 PPM
  • Hydrogen sulfide- 0-10 PPM
  • Hydrogen sulfide- 0-50 PPM
  • Hydrogen sulfide- 0-100 PPM
  • Hydrogen sulfide- 0-500 PPM
  • Nitric oxide- 0-100 PPM
  • Nitrogen dioxide- 0-10 PPM
  • Oxygen- 0-10% – compensated
  • Oxygen- 0-25% – compensated
  • Oxygen – CO2 tolerant- 0-25%
  • Oxygen – solvent tolerant- 0-25%
  • Phosphine- 0-2 PPM
  • Silane- 0-25 PPM
  • Sulfur dioxide- 0-25 PPM
  • Sulfur dioxide- 0-100 PPM
System Specifications
GAS TYPES XE, XA Combustibles, oxygen, and toxics
XIR Combustibles; 0-100% LEL
TEMPERATURE RANGE -40° C to +60° C (-40° F to +140° F)
(Typical range for some gases may differ)
DRIFT Zero Drift XE, XA <5%/year, typical
XIR ±2%/year, typical
Span Drift XE, XA <10%/year, typical
NOISE <1% full scale
ACCURACY Repeatability XE, XA, XIR ±1% full scale or 2ppm, typical
Linearity XE, XA ±2% full scale or 2ppm, (O2, CO)
XIR ±2% full scale (≤50% LEL)
XE, XA ±3% full scale (<50% LEL combustibles)
XE, XA, XIR ±5% full scale (>50% LEL combustibles)
XE, XA ±10% full scale or 2 ppm, (non-CO toxics)
RESPONSE TIMES T20 O2 & toxics XE, XA <12 seconds (typically 6 seconds)
T50 O2 & toxics XE, XA <30 seconds (typically 12 seconds)
T50 combustible XE, XA <8 seconds
T90 combustible XE, XA <30 seconds
T90 combustible XIR <2 seconds
HUMIDITY XE, XA 15%-95% RH, non-condensing
XIR 0%-95% RH, non-condensing
SENSOR LIFE Oxygen & toxics XE, XA 2 years typical
Combustible XE, XA 3 years typical
Combustible XIR 10 years typical
Warranty 1 year XE, XA; 2 years XIR; 10 years XIR, XI (IR source only)
POWER INPUT XE, XA 8-30 VDC (oxygen and toxics) 2.4 W max
XE, XA 8-30 VDC (combustibles) 5.0 W max
XIR 10-30 VDC 7.0 W max
WIRING REQUIREMENTS Combustible XE, XA, XIR 3-wire
Oxygen & toxics XE, XA 2-wire; no LEDs or relays
Oxygen & toxics XE, XA 3-wire; LEDs and/or relays
SIGNAL OUTPUT XE, XA 4-20 mA 2-wire current sink
XE, XA, XIR 4-20 mA 3-wire current source
XE, XA, XIR HART Output
RELAY CONTACT RATING 5 amp @ 220 VAC; 5 amp @ 30 VDC
HOUSING ENTRIES XE, XIR Four conduit entries, 3⁄4″ NPT or 25 mm
XA One entry
PHYSICAL XE 316 stainless steel; 10.4 lbs (4.7 kg)
6.3″ W x 3.9″ D x 10.3″ L (160 x 99 x 261 mm)
XA Polycarbonate; 1.5 lbs (0.68kg)
5.1″ W x 2.9″ D x 9.4″ L (130 x 76 x 239 mm)
XIR 316 stainless steel; 10.8 lbs (4.9 kg)
12.6″ W x 3.9″ D x 5.7″ L (320 x 99 x 144 mm)
APPROVAL RATINGS Ultima X Series Monitors USA/Canada
cFMus, cULus, CSA
Class I, Div. 1 and 2, Groups A, B, C, D
Class II, Div. 1, Groups F & G, Class III
Type 4X, IP66
ANSI/ISA 12.13.01
CSA C22.2 No.152, Class I, Div. 1, Groups A,B,C,D
CSA C22.2 No. 152, Class I, Div. 1, Groups B,C,D (XIR)
XA NEMA 4X rating
Ultima X Series Monitors Europe
CE Low Voltage/EMC/ATEX, EN 60079-1 11 2G Ex d 11C T4
Ultima X Series Monitors IP 66
(not including X3 Technology or Hart) SIL Certification
SIL 2 @ HFT=0 (oxygen, catalytic combustible, and IR)
SIL 1 @ HFT = 0: SIL 2 @ HFT = 1 (toxic)