Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter is designed with reliability in mind to withstand the most challenging environmental conditions throughout the product’s life.
MSA’s PrimaX IR Gas Transmitter offers LEL (Lower Explosive Limit) combustible gas detection through a patented PrimaX Gas Transmitter IR dual source design.
A redundant IR source provides reliability and uninterrupted monitoring should a source failure occur.
Furthermore, the possibility of obscurations due to rain, fog, dirt, dust, and other environmental conditions is minimised due to the dual source design.
In addition, optics are optimised for maximum signal, resulting in a product of extraordinary stability.
| Part Number | Description |
|---|---|
| 10144534 | PRIMAX IR, ACET 2.5, M25, ATEX, AL |
| 10144535 | PRIMAX IR, ACET 2.5, M25, ATEX, SS |
| 10144554 | PRIMAX IR, ACET 2.5, NPT, ATEX, AL |
| 10144555 | PRIMAX IR, ACET 2.5, NPT, ATEX, SS |
| 10144490 | PRIMAX IR, BUT 1.4, M25, ATEX, AL |
| 10144521 | PRIMAX IR, BUT 1.4, M25, ATEX, SS |
| 10144540 | PRIMAX IR, BUT 1.4, NPT, ATEX, AL |
| 10144541 | PRIMAX IR, BUT 1.4, NPT, ATEX, SS |
| 10152708 | PRIMAX IR, CYCLP 1.4, ATEX, M25, AL |
| 10152712 | PRIMAX IR, CYCLP 1.4, ATEX, M25, SS |
| 10152716 | PRIMAX IR, CYCLP 1.4, ATEX, NPT, AL |
| 10152720 | PRIMAX IR, CYCLP 1.4, ATEX, NPT, SS |
| 10127178 | PrimaX IR, Eth 2.7, ATEX, M25, ALUM |
| 10127180 | PrimaX IR, Eth 2.7, ATEX, M25, SS |
| 10127179 | PrimaX IR, Eth 2.7, ATEX, NPT, ALUM |
| 10127181 | PrimaX IR, Eth 2.7, ATEX, NPT, SS |
| 10115995 | PRIMAX IR, METH4.4, M25, ATEX, ALUM |
| 10115999 | PRIMAX IR, METH4.4, M25, ATEX, SS |
| 10115997 | PRIMAX IR, METH4.4, NPT, ATEX, ALUM |
| 10116001 | PRIMAX IR, METH4.4, NPT, ATEX, SS |
| 10116003 | PRIMAX IR, METH5.0, M25, ATEX, ALUM |
| 10116007 | PRIMAX IR, METH5.0, M25, ATEX, SS |
| 10116005 | PRIMAX IR, METH5.0, NPT, ATEX, ALUM |
| 10116009 | PRIMAX IR, METH5.0, NPT, ATEX, SS |
| 10115996 | PRIMAX IR, PROP1.7, M25, ATEX, ALUM |
| 10116000 | PRIMAX IR, PROP1.7, M25, ATEX, SS |
| 10115998 | PRIMAX IR, PROP1.7, NPT, ATEX, ALUM |
| 10116002 | PRIMAX IR, PROP1.7, NPT, ATEX, SS |
| Part Number | Description |
|---|---|
| 10119167 | SENSOR, PrimaX IR, Meth4.4, M25, ATEX |
| 10119168 | SENSOR, PrimaX IR, Prop1.7, M25, ATEX |
| 10119169 | SENSOR, PrimaX IR, Meth5.0, M25, ATEX |
| 10119170 | SENSOR, PrimaX IR, Prop2.1, M25, ATEX |
| 10119191 | SENSOR, PrimaX IR, Meth4.4, NPT, ATEX |
| 10119192 | SENSOR, PrimaX IR, Prop1.7, NPT, ATEX |
| 10119193 | SENSOR, PrimaX IR, Meth5.0, NPT, ATEX |
| 10119194 | SENSOR, PrimaX IR, Prop2.1, NPT, ATEX |
| Part Number | Description |
|---|---|
| 10119167 | SENSOR, PrimaX IR, Meth4.4, M25, ATEX |
| 10119168 | SENSOR, PrimaX IR, Prop1.7, M25, ATEX |
| 10119169 | SENSOR, PrimaX IR, Meth5.0, M25, ATEX |
| 10119170 | SENSOR, PrimaX IR, Prop2.1, M25, ATEX |
| 10119191 | SENSOR, PrimaX IR, Meth4.4, NPT, ATEX |
| 10119192 | SENSOR, PrimaX IR, Prop1.7, NPT, ATEX |
| 10119193 | SENSOR, PrimaX IR, Meth5.0, NPT, ATEX |
| 10119194 | SENSOR, PrimaX IR, Prop2.1, NPT, ATEX |
| Part Number | Description |
|---|---|
| 10111874 | Calibration Cap Assy, PrimaX IR (LF) |
| 10113100 | Flow Cap Assy: PrimaX IR |
| 10113481 | Sun Shield: IR Sensor |
| 10113582 | Manual: Instruction, PrimaX IR (CD Format) |
| 10113663 | Environmental Cap Assy with Labels |
| 10114097 | Tether: Environmental Guard |
| 10114373 | Kit: Duct Mount |
| 10116419 | Kit: Remote Calibration |
| 10122228 | HART Calibration Cover |
| 10114432-SP | Gasket Set PrimaX IR |
| 10122783 | HART Remote Calibration Kit |
| 10081441 | HART Port Cable (PrimaX IR & ULTIMA X) |
| Description | Specification |
| Gas Types and Ranges |
Hydrocarbon gases & vapors; 0-100 % LEL The PrimaX IR Detector is ATEX performance approved to following gases: Methane, Propane, Toluene, n-Butane, n-Pentane, n-Hexane, Propylene, Ethane, Propylene Oxide, Acetone, Cyclopentane, Ethyl Acetate, IsoButane and is shipped from the factory set and calibrated to one of these gases. Most of other flammable hydrocarbon vapours are also detectable. |
| Temperature Range | -50 °C to +80 °C (-58 °F to +176 °F) |
| Repeatability | ±1 % full-scale |
| Response Time without environmental guard | T90 < 4 sec. |
| Response Time with environmental guard |
Tested as per procedure in EN 60079-29-1. For 50 % LEL, 50% response <12 sec., 90 % response <25 sec. |
| Humidity | 0 %-95 % RH, non-condensing |
| Sensor Warranty | 10 years for IR source |
| Power Input | 18-32 VDC, 5 watts (-50 °C to +80 °C) |
| Current Draw | 350 mA RMS average @ 24 VDC |
| Wiring Requirements | 3-wire, 2.0 mm max (14 AWG) |
| Signal Output | 4-20 mA 3-wire current source with HART protocol |
| Sensor Physical Characteristics | 316 stainless steel |
| Weight | 1.5 kg (3.3 lbs.) |
| Dimensions | 89 x 203 mm (3.5” dia. x 8” long) |
| Approval Ratings |
Europe/International EN 60079-0:2009, EN 60079-1:2007 IEC 60079-31:2009 EN 60079-29-1:2007, EN 50271:2010 CE EMC Directive: 2014/30/EU II 2 G Ex d IIC T4 Gb II 2 D Ex tb IIIC T130° Db IP67 US and Canada cFMus Class I, Div.1, Groups A, B, C, & D Class II, Div.1, Groups E, F, & G Class III ANSI/ISA 12.13.01 CSA C22.2 No. 152 Combustible Gas Performance IEC China Ex/CMC/CCCF Russia Ex/EAC (Tamb -50 °C to +80 °C) |
| Ingress Protection | IP67 |
| Source Redundancy | 100 % redundancy with failure of 1st source |
| HART | Compatibility with HART 7.0 |
| Safety Integrity Level | SIL 2 |
Get in touch with us to see how we can help you with your project