The Oldham iTrans 2 can simultaneously monitor two gases, with both readings shown on a dual-channel split-screen LED display. Two integral or remote sensors can be fitted. Single-sensor operation is also possible. Offering flexibility and limiting installation costs by reducing the number of transmitters required.
A fixed-point gas detector for flammable and toxic gases, accepting infrared, catalytic bead or electrochemical sensors.
Sensors are pre-calibrated, using smart sensor technology to enable automatic sensor recognition and data transfer. Sensor life data can be accessed and displayed automatically after each calibration.
With relay options available, i-trans 2 can act as a standalone system activating alarms, shutting down equipment in the event of a hazard, and removing the need for cabling to a central controller. The transmitter can also operate with other detectors as part of a system.
Supplied with analogue 4-20mA and digital RS-485 Modbus (9600 baud) outputs. HART is optional, enabling remote communication across the 4-20mA signal for maintenance, commissioning and calibration.
| Part Number | Description |
|---|---|
| ITR2SA-11000 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm |
| ITR2SA-1100141 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, H2S 0 – 500ppm |
| ITR2SA-11001A4 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, O2 0 – 30%Vol |
| ITR2SA-1100210 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Remote, CO 0 – 999ppm, delivered without power supply |
| ITR2SA-11010 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, with power supply |
| ITR2SA-1101141 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, H2S 0 – 500ppm, delivered with power supply |
| ITR2SA-1101162 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, NO2 0 – 100ppm, with power supply |
| ITR2SA-11011A4 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, O2 0 – 30%Vol, with power supply |
| ITR2SA-11011B2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-11011C2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-11012C2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-1200162 | iTrans 2 Stand Alone – Sensor 1 – Onboard, NO 0 – 999ppm, Sensor 2 – Onboard, NO2 0 – 100ppm |
| ITR2SA-1200210 | iTrans 2 Stand Alone – Sensor 1 – Onboard, NO 0 – 999ppm, Sensor 2 – Remote, CO 0 – 999ppm |
| ITR2SA-12010 | iTrans 2 Stand Alone – Sensor 1 – Onboard, NO 0 – 999ppm, with power supply |
| ITR2SA-1201152 | iTrans 2 Stand Alone – Sensor 1 – Onboard, NO 0 – 999ppm, Sensor 2 – Onboard, SO2 0 – 100ppm, with power supply |
| ITR2SA-13110 | iTrans 2 Stand Alone – Sensor 1 – Onboard, NH3 0 – 500ppm, delivered with power supply |
| ITR2SA-14100 | iTrans 2 Stand Alone – Sensor 1 – Onboard, H2S 0 – 500ppm |
| ITR2SA-14101A4 | iTrans 2 Stand Alone – Sensor 1 – Onboard, H2S 0 – 500ppm, Sensor 2 – Onboard, O2 0 – 30%Vol |
| ITR2SA-14110 | iTrans 2 Stand Alone – Sensor 1 – Onboard, Hydrogen Sulfide (H2S) 0 – 500ppm, delivered with power supply |
| ITR2SA-14111C2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, H2S 0 – 500ppm – Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-14112C2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, H2S 0 – 500ppm – Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-15200 | iTrans 2 Stand Alone – Sensor 1 – Onboard, SO2 0 – 100ppm |
| ITR2SA-1520141 | iTrans 2 Stand Alone – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Onboard, H2S 0 – 500ppm |
| ITR2SA-15210 | iTrans 2 Stand Alone – Sensor 1 – Onboard, SO2 0 – 100ppm, with power supply |
| ITR2SA-16210 | iTrans 2 Stand Alone – Sensor 1 – Onboard, NO2 0 – 100ppm, delivered with power supply |
| ITR2SA-16211F4 | iTrans 2 Stand Alone – Sensor 1 – Onboard, NO2 0 – 100ppm – Sensor 2 – Onboard, HCL 0 – 30ppm, delivered with power supply |
| ITR2SA-17210 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CL2 0 – 100ppm, with power supply |
| ITR2SA-17211F4 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CL2 0 – 100ppm – Sensor 2 – Onboard, HCL 0 – 30ppm, delivered with power supply |
| ITR2SA-1721272 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CL2 0 – 100ppm, Sensor 2 – Remote, CL2 0 – 100ppm, with power supply |
| ITR2SA-18710 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CLO2 0 – 1ppm, delivered with power supply |
| ITR2SA-18711B2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CLO2 0 – 1ppm, Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-19400 | iTrans 2 Stand Alone – Sensor 1 – Onboard, HCN 0 – 30ppm, delivered without power supply |
| ITR2SA-19410 | iTrans 2 Stand Alone – Sensor 1 – Onboard, HCN 0 – 30ppm, with power supply |
| ITR2SA-1A400 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol |
| ITR2SA-1A401B2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol – Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, delivered without power supply |
| ITR2SA-1A402A4 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol, Sensor 2 – Remote, O2 0 – 30%Vol |
| ITR2SA-1A402C2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol – Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, delivered without power supply |
| ITR2SA-1A402L0 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol, Sensor 2 – Remote, H2 0 – 999ppm |
| ITR2SA-1A410 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol, with power supply |
| ITR2SA-1A411A4 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol – Sensor 2 – Onboard, O2 0 – 30%Vol, delivered with power supply |
| ITR2SA-1A411C2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, O2 0 – 30%Vol, Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-1B200 | iTrans 2 Stand Alone – Sensor 1 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL |
| ITR2SA-1B210 | iTrans 2 Stand Alone – Sensor 1 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-1B212B2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL – Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-1C200 | iTrans 2 Stand Alone – Sensor 1 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL |
| ITR2SA-1C20141 | iTrans 2 Stand Alone – Sensor 1 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, Sensor 2 – Onboard, H2S 0 – 500ppm |
| ITR2SA-1C210 | iTrans 2 Stand Alone – Sensor 1 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-1C212C2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-1D000 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO-H2 0 – 999ppm |
| ITR2SA-1D002D0 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO-H2 0 – 999ppm, Sensor 2 – Remote, CO-H2 0 – 999ppm |
| ITR2SA-1D002L0 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO-H2 0 – 999ppm, Sensor 2 – Remote, H2 0 – 999ppm |
| ITR2SA-1D010 | iTrans 2 Stand Alone – Sensor 1 – Onboard, CO-H2 0 – 999ppm, delivered with power supply |
| ITR2SA-1F410 | iTrans 2 Stand Alone – Sensor 1 – Onboard, HCL 0 – 30ppm, delivered with power supply |
| ITR2SA-1L000 | iTrans 2 Stand Alone – Sensor 1 – Onboard, H2 0 – 999ppm |
| ITR2SA-1L012B2 | iTrans 2 Stand Alone – Sensor 1 – Onboard, H2 0 – 999ppm, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-1VA00 | iTrans 2 Stand Alone – Sensor 1 – Onboard, IR-CO2 0 – 5.00%Vol, delivered without power supply |
| ITR2SA-1VA10 | iTrans 2 Stand Alone – Sensor 1 – Onboard, IR-CO2 0 – 5.00%Vol, delivered with power supply |
| ITR2SA-1XB10 | iTrans 2 Stand Alone – Sensor 1 – Onboard, IR-CO2 0 – 0.50%Vol, delivered with power supply |
| Part Number | Description |
|---|---|
| ITR2SA-21000 | iTrans 2 Stand Alone – Sensor 1 – Remote, CO 0 – 999ppm, delivered without power supply |
| ITR2SA-2100241 | iTrans 2 Stand Alone – Sensor 1 – Remote, CO 0 – 999ppm, Sensor 2 – Remote, H2S 0 – 500ppm |
| ITR2SA-2100262 | iTrans 2 Stand Alone – Sensor 1 – Remote, Carbon Monoxide (CO) 0 – 999ppm – Sensor 2 – Remote, Nitrogen Dioxide (NO2) 0 – 100ppm, delivered without power supply |
| ITR2SA-21002A4 | iTrans 2 Stand Alone – Sensor 1 – Remote, CO 0 – 999ppm – Sensor 2 – Remote, O2 0 – 30%Vol, delivered without power supply |
| ITR2SA-21010 | iTrans 2 Stand Alone – Sensor 1 – Remote, CO 0 – 999ppm, delivered with power supply |
| ITR2SA-2101210 | iTrans 2 Stand Alone – Sensor 1 – Remote, CO 0 – 999ppm, Sensor 2 – Remote, CO 0 – 999ppm, with power supply |
| ITR2SA-21012B2 | iTrans 2 Stand Alone – Sensor 1 – Remote, CO 0 – 999ppm, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-24100 | iTrans 2 Stand Alone – Sensor 1 – Remote, H2S 0 – 500ppm |
| ITR2SA-2410241 | iTrans 2 Stand Alone – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, H2S 0 – 500ppm |
| ITR2SA-24102B2 | iTrans 2 Stand Alone – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL |
| ITR2SA-24110 | iTrans 2 Stand Alone – Sensor 1 – Remote, H2S 0 – 500ppm, delivered with power supply |
| ITR2SA-2411241 | iTrans 2 Stand Alone – Sensor 1 – Remote, H2S 0 – 500ppm – Sensor 2 – Remote, H2S 0 – 500ppm, delivered with power supply |
| ITR2SA-2411272 | iTrans 2 Stand Alone – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, CL2 0 – 100ppm, with power supply |
| ITR2SA-24112B2 | iTrans 2 Stand Alone – Sensor 1 – Remote, H2S 0 – 500ppm – Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-25200 | iTrans 2 Stand Alone – Sensor 1 – Remote, SO2 0 – 100ppm |
| ITR2SA-2520252 | iTrans 2 Stand Alone – Sensor 1 – Remote, SO2 0 – 100ppm, Sensor 2 – Remote, SO2 0 – 100ppm |
| ITR2SA-25210 | iTrans 2 Stand Alone – Sensor 1 – Remote, SO2 0 – 100ppm, with power supply |
| ITR2SA-26200 | iTrans 2 Stand Alone – Sensor 1 – Remote, NO2 0 – 100ppm, delivered without power supply |
| ITR2SA-27200 | iTrans 2 Stand Alone – Sensor 1 – Remote, CL2 0 – 100ppm, delivered without power supply |
| ITR2SA-27210 | iTrans 2 Stand Alone – Sensor 1 – Remote, CL2 0 – 100ppm, delivered with power supply |
| ITR2SA-29400 | iTrans 2 Stand Alone – Sensor 1 – Remote, Hydrogen Cyanide (HCN) 0 – 30ppm, delivered without power supply |
| ITR2SA-29410 | iTrans 2 Stand Alone – Sensor 1 – Remote, HCN 0 – 30ppm, with power supply |
| ITR2SA-2A400 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol |
| ITR2SA-2A40262 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol – Sensor 2 – Remote, NO2 0 – 100ppm, delivered without power supply |
| ITR2SA-2A402A4 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol, Sensor 2 – Remote, O2 0 – 30%Vol |
| ITR2SA-2A402C2 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol, Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL |
| ITR2SA-2A402L0 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol, Sensor 2 – Remote, H2 0 – 999ppm |
| ITR2SA-2A410 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol, with power supply |
| ITR2SA-2A412A4 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol – Sensor 2 – Remote, O2 0 – 30%Vol, delivered with power supply |
| ITR2SA-2A412B2 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-2A412C2 | iTrans 2 Stand Alone – Sensor 1 – Remote, O2 0 – 30%Vol – Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-2B200 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, delivered without power supply |
| ITR2SA-2B202B2 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL |
| ITR2SA-2B210 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-2B212B2 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with power supply |
| ITR2SA-2C200 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL |
| ITR2SA-2C20210 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, Sensor 2 – Remote, CO 0 – 999ppm |
| ITR2SA-2C202C2 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL – Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, delivered without power supply |
| ITR2SA-2C210 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-2C21241 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic Plug-In (factory Pentane calibration) 0 – 100%LEL – Sensor 2 – Remote, Hydrogen Sulfide (H2S) 0 – 500ppm, delivered with power supply |
| ITR2SA-2C212C2 | iTrans 2 Stand Alone – Sensor 1 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL – Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, delivered with power supply |
| ITR2SA-2D012A4 | iTrans 2 Stand Alone – Sensor 1 – Remote, CO-H2 0 – 999ppm, Sensor 2 – Remote, O2 0 – 30%Vol, with power supply |
| ITR2SA-2K710 | iTrans 2 Stand Alone – Sensor 1 – Remote, PH3 0 – 1ppm, with power supply |
| ITR2SA-2VA00 | iTrans 2 Stand Alone – Sensor 1 – Remote, IR-CO2 0 – 5.00%Vol |
| ITR2SA-2VA10 | iTrans 2 Stand Alone – Sensor 1 – Remote, IR-CO2 0 – 5.00%Vol, with power supply |
| ITR2SA-2W200 | iTrans 2 Stand Alone – Sensor 1 – Remote, IR-CO2 0 – 100%Vol, delivered without power supply |
| Part Number | Description |
|---|---|
| ITR2SA-8W208A4 | iTrans 2 Stand Alone – Dual sensors on one Remote enclosure, IR-CO2 0 – 100%Vol / O2 0 – 30%Vol |
| Part Number | Description |
|---|---|
| ITRANS2-11000 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm |
| ITRANS2-1100110 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, CO 0 – 999ppm |
| ITRANS2-1100131 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, NH3 0 – 500ppm, Modbus communication |
| ITRANS2-1100141 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, H2S 0 – 500ppm |
| ITRANS2-1100162 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, NO2 0 – 100ppm, Modbus communication |
| ITRANS2-11001A4 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, O2 0 – 30%Vol |
| ITRANS2-11001B2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, Modbus communication |
| ITRANS2-11001C2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, Modbus communication |
| ITRANS2-1100210 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Remote, CO 0 – 999ppm, Modbus communication |
| ITRANS2-1100220 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Remote, NO 0 – 999ppm |
| ITRANS2-1100262 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Remote, NO2 0 – 100ppm, Modbus communication |
| ITRANS2-11002B2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL |
| ITRANS2-11010 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, relays |
| ITRANS2-1101120 | iTrans 2 – Sensor 1 – Onboard, Carbon Monoxide (CO) 0 – 999ppm – Sensor 2 – Onboard, Nitric Oxide (NO) 0 – 999ppm, relays, Modbus communication |
| ITRANS2-1101141 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, H2S 0 – 500ppm, relays |
| ITRANS2-1101152 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, SO2 0 – 100ppm, relays, Modbus communication |
| ITRANS2-1101162 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, NO2 0 – 100ppm, relays |
| ITRANS2-1101194 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, HCN 0 – 30ppm, relays, Modbus communication |
| ITRANS2-11011A4 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, O2 0 – 30%Vol, relays |
| ITRANS2-11011B2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, relays |
| ITRANS2-11011C2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, relays |
| ITRANS2-11011L0 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, H2 0 – 999ppm, relays |
| ITRANS2-11011VA | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, IR-CO2 0 – 5.00%Vol, relays |
| ITRANS2-11011W2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, IR-CO2 0 – 100%Vol, relays, Modbus communication |
| ITRANS2-1101210 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Remote, CO 0 – 999ppm, relays |
| ITRANS2-1101241 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Remote, H2S 0 – 500ppm, relays |
| ITRANS2-11012A4 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Remote, O2 0 – 30%Vol, relays |
| ITRANS2-11012B2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, relays |
| ITRANS2-11012F4 | iTrans 2 – Sensor 1 – Onboard, Carbon Monoxide (CO) 0 – 999ppm – Sensor 2 – Remote, Hydrogen Chloride (HCl) 0 – 30ppm, relays, Modbus communication |
| ITRANS2-11020 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, with HART |
| ITRANS2-1102162 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, NO2 0 – 100ppm, with HART, no relay |
| ITRANS2-11021C2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, with HART, no relay |
| ITRANS2-11030 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, with HART, relays |
| ITRANS2-11031A4 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm, Sensor 2 – Onboard, O2 0 – 30%Vol, with HART, relays |
| ITRANS2-11031B2 | iTrans 2 – Sensor 1 – Onboard, Carbon Monoxide (CO) 0 – 999ppm – Sensor 2 – Onboard, LEL Catalytic Plug-In (factory Methane calibration) 0 – 100%LEL, with HART, relays |
| ITRANS2-11032B2 | iTrans 2 – Sensor 1 – Onboard, CO 0 – 999ppm – Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with HART, relays |
| ITRANS2-12000 | iTrans 2 – Sensor 1 – Onboard, NO 0 – 999ppm |
| ITRANS2-1200152 | iTrans 2 – Sensor 1 – Onboard, NO 0 – 999ppm, Sensor 2 – Onboard, SO2 0 – 100ppm |
| ITRANS2-1200162 | iTrans 2 – Sensor 1 – Onboard, NO 0 – 999ppm – Sensor 2 – Onboard, NO2 0 – 100ppm, Modbus communication |
| ITRANS2-12010 | iTrans 2 – Sensor 1 – Onboard, NO 0 – 999ppm, relays |
| ITRANS2-1201152 | iTrans 2 – Sensor 1 – Onboard, NO 0 – 999ppm – Sensor 2 – Onboard, SO2 0 – 100ppm, relays, Modbus communication |
| ITRANS2-1201162 | iTrans 2 – Sensor 1 – Onboard, NO 0 – 999ppm, Sensor 2 – Onboard, NO2 0 – 100ppm, relays |
| ITRANS2-13100 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm |
| ITRANS2-1310231 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm, Sensor 2 – Remote, NH3 0 – 500ppm |
| ITRANS2-13110 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm, relays |
| ITRANS2-1311131 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm, Sensor 2 – Onboard, NH3 0 – 500ppm, relays |
| ITRANS2-1311141 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm, Sensor 2 – Onboard, H2S 0 – 500ppm, relays |
| ITRANS2-1311152 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm, Sensor 2 – Onboard, SO2 0 – 100ppm, relays |
| ITRANS2-13111A4 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm – Sensor 2 – Onboard, O2 0 – 30%Vol, relays, Modbus communication |
| ITRANS2-13111B2 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm – Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, relays, Modbus communication |
| ITRANS2-13111F4 | iTrans 2 – Sensor 1 – Onboard, Ammonia (NH3) 0 – 500ppm – Sensor 2 – Onboard, Hydrogen Chloride (HCl) 0 – 30ppm, relays, Modbus communication |
| ITRANS2-1311231 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm – Sensor 2 – Remote, NH3 0 – 500ppm, relays, Modbus communication |
| ITRANS2-13120 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm, with HART |
| ITRANS2-13130 | iTrans 2 – Sensor 1 – Onboard, NH3 0 – 500ppm, with HART, relays |
| ITRANS2-1520262 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Remote, NO2 0 – 100ppm |
| ITRANS2-15210 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, relays |
| ITRANS2-15211A4 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Onboard, O2 0 – 30%Vol, relays |
| ITRANS2-15211B2 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, relays |
| ITRANS2-15211VA | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm – Sensor 2 – Onboard, IR-CO2 0 – 5.00%Vol, relays, Modbus communication |
| ITRANS2-1521252 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Remote, SO2 0 – 100ppm, relays |
| ITRANS2-15220 | iTrans 2 – Sensor 1 – Onboard, Sulfur Dioxide (SO2) 0 – 100ppm, with HART, no relay |
| ITRANS2-15230 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, with HART, relays |
| ITRANS2-16200 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm |
| ITRANS2-1620262 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, Sensor 2 – Remote, NO2 0 – 100ppm |
| ITRANS2-16210 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, relays |
| ITRANS2-1621120 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm – Sensor 2 – Onboard, NO 0 – 999ppm, relays, Modbus communication |
| ITRANS2-1621162 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, Sensor 2 – Onboard, NO2 0 – 100ppm, relays |
| ITRANS2-1621194 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm – Sensor 2 – Onboard, HCN 0 – 30ppm, relays, Modbus communication |
| ITRANS2-16211C2 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, relays |
| ITRANS2-16211D0 | iTrans 2 – Sensor 1 – Onboard, Nitrogen Dioxide (NO2) 0 – 100ppm – Sensor 2 – Onboard, Carbon Monoxide – Hydrogen Null (CO – H2) 0 – 999ppm, relays, Modbus communication |
| ITRANS2-16211F4 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm – Sensor 2 – Onboard, HCL 0 – 30ppm, relays, Modbus communication |
| ITRANS2-16220 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, with HART, no relay |
| ITRANS2-17200 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm |
| ITRANS2-1720194 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm – Sensor 2 – Onboard, HCN 0 – 30ppm, Modbus communication |
| ITRANS2-17201F4 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm – Sensor 2 – Onboard, HCL 0 – 30ppm, Modbus communication |
| ITRANS2-1720272 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm – Sensor 2 – Remote, CL2 0 – 100ppm, Modbus communication |
| ITRANS2-17210 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, relays |
| ITRANS2-17211F4 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, Sensor 2 – Onboard, HCL 0 – 30ppm, relays |
| ITRANS2-1721272 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, Sensor 2 – Remote, CL2 0 – 100ppm, relays |
| ITRANS2-17220 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, with HART, no relay |
| ITRANS2-17230 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, with HART, relays |
| ITRANS217231F4 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, Sensor 2 – Onboard, HCL 0 – 30ppm, with HART, relays |
| ITRANS2-18700 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm |
| ITRANS2-1870287 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm, Sensor 2 – Remote, CLO2 0 – 1ppm |
| ITRANS2-18710 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm, relays |
| ITRANS2-18731A4 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm – Sensor 2 – Onboard, O2 0 – 30%Vol, with HART, relays |
| ITRANS2-19400 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm |
| ITRANS2-19410 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm, relays |
| ITRANS2-1941194 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm – Sensor 2 – Onboard, HCN 0 – 30ppm, relays, Modbus communication |
| ITRANS2-19411A4 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm, Sensor 2 – Onboard, O2 0 – 30%Vol, relays |
| ITRANS2-19420 | iTrans 2 – Sensor 1 – Onboard, Hydrogen Cyanide (HCN) 0 – 30ppm, with HART, no relay |
| ITRANS2-19430 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm, with HART, relays |
| ITRANS2-1520262 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Remote, NO2 0 – 100ppm |
| ITRANS2-15210 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, relays |
| ITRANS2-15211A4 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Onboard, O2 0 – 30%Vol, relays |
| ITRANS2-15211B2 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Onboard, LEL Catalytic (factory methane calibration) 0 – 100%LEL, relays |
| ITRANS2-15211VA | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm – Sensor 2 – Onboard, IR-CO2 0 – 5.00%Vol, relays, Modbus communication |
| ITRANS2-1521252 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, Sensor 2 – Remote, SO2 0 – 100ppm, relays |
| ITRANS2-15220 | iTrans 2 – Sensor 1 – Onboard, Sulfur Dioxide (SO2) 0 – 100ppm, with HART, no relay |
| ITRANS2-15230 | iTrans 2 – Sensor 1 – Onboard, SO2 0 – 100ppm, with HART, relays |
| ITRANS2-16200 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm |
| ITRANS2-1620262 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, Sensor 2 – Remote, NO2 0 – 100ppm |
| ITRANS2-16210 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, relays |
| ITRANS2-1621120 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm – Sensor 2 – Onboard, NO 0 – 999ppm, relays, Modbus communication |
| ITRANS2-1621162 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, Sensor 2 – Onboard, NO2 0 – 100ppm, relays |
| ITRANS2-1621194 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm – Sensor 2 – Onboard, HCN 0 – 30ppm, relays, Modbus communication |
| ITRANS2-16211C2 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, Sensor 2 – Onboard, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, relays |
| ITRANS2-16211D0 | iTrans 2 – Sensor 1 – Onboard, Nitrogen Dioxide (NO2) 0 – 100ppm – Sensor 2 – Onboard, Carbon Monoxide – Hydrogen Null (CO – H2) 0 – 999ppm, relays, Modbus communication |
| ITRANS2-16211F4 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm – Sensor 2 – Onboard, HCL 0 – 30ppm, relays, Modbus communication |
| ITRANS2-16220 | iTrans 2 – Sensor 1 – Onboard, NO2 0 – 100ppm, with HART, no relay |
| ITRANS2-17200 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm |
| ITRANS2-1720194 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm – Sensor 2 – Onboard, HCN 0 – 30ppm, Modbus communication |
| ITRANS2-17201F4 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm – Sensor 2 – Onboard, HCL 0 – 30ppm, Modbus communication |
| ITRANS2-1720272 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm – Sensor 2 – Remote, CL2 0 – 100ppm, Modbus communication |
| ITRANS2-17210 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, relays |
| ITRANS2-17211F4 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, Sensor 2 – Onboard, HCL 0 – 30ppm, relays |
| ITRANS2-1721272 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, Sensor 2 – Remote, CL2 0 – 100ppm, relays |
| ITRANS2-17220 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, with HART, no relay |
| ITRANS2-17230 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, with HART, relays |
| ITRANS217231F4 | iTrans 2 – Sensor 1 – Onboard, CL2 0 – 100ppm, Sensor 2 – Onboard, HCL 0 – 30ppm, with HART, relays |
| ITRANS2-18700 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm |
| ITRANS2-1870287 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm, Sensor 2 – Remote, CLO2 0 – 1ppm |
| ITRANS2-18710 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm, relays |
| ITRANS2-18731A4 | iTrans 2 – Sensor 1 – Onboard, CLO2 0 – 1ppm – Sensor 2 – Onboard, O2 0 – 30%Vol, with HART, relays |
| ITRANS2-19400 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm |
| ITRANS2-19410 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm, relays |
| ITRANS2-1941194 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm – Sensor 2 – Onboard, HCN 0 – 30ppm, relays, Modbus communication |
| ITRANS2-19411A4 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm, Sensor 2 – Onboard, O2 0 – 30%Vol, relays |
| ITRANS2-19420 | iTrans 2 – Sensor 1 – Onboard, Hydrogen Cyanide (HCN) 0 – 30ppm, with HART, no relay |
| ITRANS2-19430 | iTrans 2 – Sensor 1 – Onboard, HCN 0 – 30ppm, with HART, relays |
| ITRANS2-2411241 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, H2S 0 – 500ppm, relays |
| ITRANS2-2411252 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm – Sensor 2 – Remote, SO2 0 – 100ppm, relays, Modbus communication |
| ITRANS2-2411272 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm – Sensor 2 – Remote, CL2 0 – 100ppm, relays, Modbus communication |
| ITRANS2-2411287 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, CLO2 0 – 1ppm, relays |
| ITRANS2-2411294 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm – Sensor 2 – Remote, HCN 0 – 30ppm, relays, Modbus communication |
| ITRANS2-24112A4 | iTrans 2 – Sensor 1 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL – Sensor 2 – Onboard, CO-H2 0 – 999ppm, relays, Modbus communication |
| ITRANS2-24112B2 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, relays |
| ITRANS2-24112C2 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, LEL Catalytic (factory pentane calibration) 0 – 100%LEL, relays |
| ITRANS2-24112K7 | iTrans 2 – Sensor 1 – Remote, Hydrogen Sulfide (H2S) 0 – 500ppm – Sensor 2 – Remote, Phosphine (PH3) 0 – 1ppm, relays, Modbus communication |
| ITRANS2-24120 | iTrans 2 – Sensor 1 – Remote, Hydrogen Sulfide (H2S) 0 – 500ppm, with HART, no relay |
| ITRANS2-24122B2 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm – Sensor 2 – Remote, LEL Catalytic (factory methane calibration) 0 – 100%LEL, with HART, no relay |
| ITRANS2-24130 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm, with HART, relays |
| ITRANS2-2413241 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, H2S 0 – 500ppm, with HART, relays |
| ITRANS2-24132B2 | iTrans 2 – Sensor 1 – Remote, Hydrogen Sulfide (H2S) 0 – 500ppm – Sensor 2 – Remote, LEL Catalytic Plug-In (factory Methane calibration) 0 – 100%LEL, with HART, relays |
| ITRANS2-25200 | iTrans 2 – Sensor 1 – Remote, SO2 0 – 100ppm |
| ITRANS2-2520252 | iTrans 2 – Sensor 1 – Remote, SO2 0 – 100ppm, Sensor 2 – Remote, SO2 0 – 100ppm |
| ITRANS2-2520294 | iTrans 2 – Sensor 1 – Remote, Sulfur Dioxide (SO2) 0 – 100ppm – Sensor 2 – Remote, Hydrogen Cyanide (HCN) 0 – 30ppm, Modbus communication |
| ITRANS2-25210 | iTrans 2 – Sensor 1 – Remote, SO2 0 – 100ppm, relays |
| ITRANS2-2521241 | iTrans 2 – Sensor 1 – Remote, H2S 0 – 500ppm, Sensor 2 – Remote, SO2 0 – 100ppm, relays |
| ITRANS2-2521262 | iTrans 2 – Sensor 1 – Remote, SO2 0 – 100ppm, Sensor 2 – Remote, NO2 0 – 100ppm, relays |
| ITRANS2-2521272 | iTrans 2 – Sensor 1 – Remote, SO2 0 – 100ppm, Sensor 2 – Remote, CL2 0 – 100ppm, relays |
| ITRANS2-2523252 | iTrans 2 – Sensor 1 – Remote, SO2 0 – 100ppm, Sensor 2 – Remote, SO2 0 – 100ppm, with HART, relays |
| ITRANS2-3B213B2 | iTrans 2 – Sensor 1 – Remote duct mount (non-hazardous), LEL Catalytic (factory methane calibration) 0 – 100%LEL – Sensor 2 – Remote duct mount (non-hazardous), LEL Catalytic (factory methane calibration) 0 – 100%LEL, relays, Modbus communication |
| ITRANS2-3C200 | iTrans 2 – Sensor 1 – Remote duct mount (non-hazardous), LEL Catalytic (factory pentane calibration) 0 – 100%LEL |
| ITRANS2-3C210 | iTrans 2 – Sensor 1 – Remote duct mount (non-hazardous), LEL Catalytic (factory pentane calibration) 0 – 100%LEL, relays |
| ITRANS2-3C213A4 | iTrans 2 – Sensor 1 – Remote duct mount (non-hazardous), LEL Catalytic (factory pentane calibration) 0 – 100%LEL, Sensor 2 – Remote duct mount (non-hazardous), O2 0 – 30%Vol, relays |
| ITRANS2-3F400 | iTrans 2 – Sensor 1 – Remote duct mount (non-hazardous), HCL 0 – 30ppm, Modbus communication |
| iTrans 2 – Stainless Steel | |
| ITRANS2-61000 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, CO 0 – 999ppm, Modbus communication |
| ITRANS2-61010 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, CO 0 – 999ppm, relays |
| ITRANS2-61017VA | iTrans 2 – Sensor 1 – Stainless steel, Onboard, CO 0 – 999ppm, Sensor 2 – Stainless steel, Remote, IR-CO2 0 – 5.00%Vol, relays |
| ITRANS2-63110 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, NH3 0 – 500ppm, relays |
| ITRANS2-6311731 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, NH3 0 – 500ppm, Sensor 2 – Stainless steel, Remote, NH3 0 – 500ppm, relays |
| ITRANS2-6311741 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, Ammonia (NH3) 0 – 500ppm – Sensor 2 – Stainless steel, Remote, Hydrogen Sulfide (H2S) 0 – 500ppm, relays, Modbus communication |
| ITRANS2-63120 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, Ammonia (NH3) 0 – 500ppm, with HART, no relay |
| ITRANS2-63130 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, NH3 0 – 500ppm, with HART, relays |
| ITRANS2-64100 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, H2S 0 – 500ppm |
| ITRANS2-64110 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, H2S 0 – 500ppm, relays |
| ITRANS2-64120 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, H2S 0 – 500ppm, with HART, no relay |
| ITRANS2-64130 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, H2S 0 – 500ppm, with HART, relays |
| ITRANS2-6413741 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, Hydrogen Sulfide (H2S) 0 – 500ppm – Sensor 2 – Stainless steel, Remote, Hydrogen Sulfide (H2S) 0 – 500ppm, with HART, relays |
| ITRANS2-65200 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, SO2 0 – 100ppm, Modbus communication |
| ITRANS2-65210 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, SO2 0 – 100ppm, relays, Modbus communication |
| ITRANS2-6521762 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, SO2 0 – 100ppm, Sensor 2 – Stainless steel, Remote, NO2 0 – 100ppm, relays |
| ITRANS2-65220 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, SO2 0 – 100ppm, with HART, no relay |
| ITRANS2-65230 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, SO2 0 – 100ppm, with HART, relays |
| ITRANS2-66200 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, NO2 0 – 100ppm |
| ITRANS2-66210 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, Nitrogen Dioxide (NO2) 0 – 100ppm, relays, Modbus communication |
| ITRANS2-6621762 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, NO2 0 – 100ppm, Sensor 2 – Stainless steel, Remote, NO2 0 – 100ppm, relays |
| ITRANS2-66217F4 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, NO2 0 – 100ppm – Sensor 2 – Stainless steel, Remote, HCL 0 – 30ppm, relays, Modbus communication |
| ITRANS2-66220 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, NO2 0 – 100ppm, with HART, no relay |
| ITRANS2-67200 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, CL2 0 – 100ppm, Modbus communication |
| ITRANS2-67210 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, CL2 0 – 100ppm, relays, Modbus communication |
| ITRANS2-67220 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, CL2 0 – 100ppm, with HART, no relay |
| ITRANS2-69400 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, HCN 0 – 30ppm |
| ITRANS2-69410 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, HCN 0 – 30ppm, relays |
| ITRANS2-69430 | iTrans 2 – Sensor 1 – Stainless steel, Onboard, HCN 0 – 30ppm, with HART, relays |
77036379-1 – Carbon Monoxide (CO)
77036379-2 – Nitric Oxide (NO)
77036379-3 – Ammonia (NH3)
77036379-4 – Hydrogen Sulfide (H2S)
77036379-5 – Sulfur Dioxide (SO2)
77036379-6 – Nitrogen Dioxide (NO2)
77036379-7 – Chlorine (Cl2)
77036379-8 – Chlorine Dioxide (ClO2)
77036379-9 – Hydrogen Cyanide (HCN)
77036379-A – Oxygen (O2)
77036379-B – Combustible Gas – Catalytic (LEL), Factory Methane Calibration
77036379-C – Combustible Gas – Catalytic (LEL), Factory Pentane Calibration
77036379-D – Carbon Monoxide / Hydrogen Null (CO/H2-Null)
77036379-F – Hydrogen Chloride (HCl)
77036379-K – Phosphine (PH3)
77036379-L – Hydrogen (H2)
77036379-M – Methane 0–100% Vol Infrared (IR) – NOT CSA CERTIFIED
77036379-N – Methane LEL Infrared (IR) – NOT CSA CERTIFIED
77036379-O – Propane LEL Infrared (IR) – NOT CSA CERTIFIED
77036379-Q – Pentane LEL Infrared (IR) – NOT CSA CERTIFIED
77036379-R – Butane LEL Infrared (IR) – NOT CSA CERTIFIED
77036379-U – Hexane LEL Infrared (IR) – NOT CSA CERTIFIED
77036379-V – CO2 (5% Vol) Infrared (IR) – NOT CSA CERTIFIED
77036379-X – CO2 (100% Vol) Infrared (IR)
77036379-W – CO2 (0.5% Vol) Infrared (IR)
77024404 – Combustible Gas – Catalytic (LEL) Replacement Sensor
77024412 – Oxygen (O2) Replacement Sensor
77024420 – Hydrogen Sulfide (H2S) Replacement Sensor
77024438 – Carbon Monoxide (CO) Replacement Sensor
77024446 – Hydrogen (H2-ppm) Replacement Sensor
77040003 – Ammonia (NH3) Replacement Sensor
77024461 – Hydrogen Chloride (HCl) Replacement Sensor
77024479 – Chlorine (Cl2) Replacement Sensor
77024487 – Nitric Oxide (NO) Replacement Sensor
77024495 – Nitrogen Dioxide (NO2) Replacement Sensor
77024503 – Sulfur Dioxide (SO2) Replacement Sensor
77024511 – Chlorine Dioxide (ClO2) Replacement Sensor
77025872 – Phosphine (PH3) Replacement Sensor
77025898 – Hydrogen Cyanide (HCN) Replacement Sensor
77027944 – Carbon Monoxide (CO) – Hydrogen Null Replacement Sensor
78105035 – Methane 100% Vol Infrared (IR) Replacement Sensor for iTrans 2 Only – NOT CSA CERTIFIED
78105036 – Methane 100% LEL Infrared (IR) Replacement Sensor for iTrans 2 Only – NOT CSA CERTIFIED
78105037 – Propane 100% LEL Infrared (IR) Replacement Sensor for iTrans 2 Only – NOT CSA CERTIFIED
78105039 – Pentane 100% LEL Infrared (IR) Replacement Sensor for iTrans 2 Only – NOT CSA CERTIFIED
78105040 – Butane 100% LEL Infrared (IR) Replacement Sensor for iTrans 2 Only – NOT CSA CERTIFIED
78105043 – Hexane 100% LEL Infrared (IR) Replacement Sensor for iTrans 2 Only – NOT CSA CERTIFIED
78105044 – CO2 100% Vol Infrared (IR) Replacement Sensor for iTrans 2 Only
78105045 – CO2 5% Vol Infrared (IR) Replacement Sensor for iTrans 2 Only
78105046 – CO2 0.5% Vol Infrared (IR) Replacement Sensor for iTrans 2 Only
78104312-STND – Duct Mount Kit for iTrans & iTrans 2 Catalytic/Toxic/Oxygen Sensors (Also iTrans 2 Infrared Sensors)
78100008 – iTrans Chassis Without Relays (Rev. 8 or Below)
78104635 – iTrans Chassis Without Relays (Rev. 9 or Above)
78100008R – iTrans Chassis With Relays (Rev. 8 or Below)
78104635R – iTrans Chassis With Relays (Rev. 9 or Above)
78100008-S – Stainless Steel iTrans Chassis Without Relays (Rev. 8 or Below)
78104635-S – Stainless Steel iTrans Chassis Without Relays (Rev. 9 or Above)
78100008R-S – Stainless Steel iTrans Chassis With Relays (Rev. 8 or Below)
78104635R-S – Stainless Steel iTrans Chassis With Relays (Rev. 9 or Above)
78105049 – iTrans 2 Chassis with Electronics Module, Without Relays
78105049R – iTrans 2 Chassis with Electronics Module, With Relays
78105049H – iTrans 2 Chassis with Electronics Module, With HART
78105049HR – iTrans 2 Chassis with Electronics Module, With HART & Relays
78105049-S – Stainless Steel iTrans 2 Chassis with Electronics Module, Without Relays
78105049R-S – Stainless Steel iTrans 2 Chassis with Electronics Module, With Relays
78105049H-S – Stainless Steel iTrans 2 Chassis with Electronics Module, With HART
78105049HR-S – Stainless Steel iTrans 2 Chassis with Electronics Module, With HART & Relays
77023760 – iTrans & iTrans 2 Terminal Power Board Without Relays (Rev. 9 or Above)
77022184 – iTrans & iTrans 2 Terminal Power Board With Relays (Rev. 9 or Above)
77026078 – iTrans & iTrans 2 Terminal Board, Remote Housing (All Revisions)
77023812 – iTrans Main Electronics Board Assembly & Display Module (Rev. 8 or Below)
77023919 – iTrans & iTrans 2 Main Electronics Board Assembly & Display Module (Rev. 9 or Above)
77026988 – Stainless Steel Smart Sensor Enclosure with Boards (Rev. 8 or Below)
77025888 – Smart Sensor Enclosure Assembly with Boards (Rev. 8 or Below)
77025948 – Smart Sensor Enclosure Assembly with Boards (Rev. 9 or Above)
77026912 – Stainless Steel Smart Sensor Enclosure Assembly with Boards (Rev. 9 or Above)
77026367 – Remote Sensor Enclosure with Terminal Board (Rev. 8 or Below)
77025286 – Sensor Enclosure for Cl2, ClO2, NH3 (Rev. 9 or Above)
77026094 – Enclosure for LEL, O2, Toxic Sensors (Rev. 9 or Above)
77036379 – Remote Sensor Enclosure with Terminal Board (Rev. 9 or Above)
77024812 – Sensor Board Stack (Rev. 8 or Below)
77024396 – Sensor Board Stack (Rev. 9 or Above)
77036303 – iTrans 2 Electronics Module (Rev. 9)
77023927 – Smart Sensor O2
77022606 – Smart Sensor LEL
77023828 – Smart Sensor H2S
77023836 – Smart Sensor CO
77023513 – Calibration Cup
77023588 – Splash Guard
77015303 – Splash Guard / Remote Calibration Cup for Catalytic, Toxic, Oxygen & Infrared Sensors
77018083 – Replacement Filter for 77015303
77014579 – By-Pass / Flow-Thru Kit (Not Suitable for Infrared Sensors)
77024065 – Calibration Wand
17049927 – Gore-Tex Water Barrier
77025971 – Ribbon Cable
77022333 – Keypad
37000352 – Flame Arrestor