Honeywell Sensepoint XCD RTD

  1. Home
  2. Products

Honeywell Sensepoint XCD RTD

The Honeywell Analytics Sensepoint XCD RTD makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div. 2 areas. You can mount the unit up to 100 feet from the transmitter to obtain maximum gas detection coverage in areas not easily accessible or where the sensor would not be visible, as in high-or low-level concealed areas or detection outside the room being monitored.

XCD RTD offers unrivalled flexibility and performance via its easily recognizable display (traffic light pattern) to convey safety status, communication and mounting options, and onboard diagnostics.

Get More Return on Investment from the Practical Advantages of XCD RTD. Sensepoint toxic and oxygen sensors detect a wide variety of industrial gases at common measuring ranges, adding flexibility to your gas monitoring program, reducing parts procurement costs and expanding your safety net.

Remote gas monitoring has never been this easy and cost-effective. Mount the sensor as shown in the illustration and view gas safety status via the large tri-colour display on the transmitter, up to 100 feet away from the sensor. The advantages of this remote monitoring system are added safety and reduced time spent on maintenance. There’s no need for your team to climb ladders or bring in specialized equipment to view gas concentration readings or conduct a safety audit. What’s more, the removable sensor design of Sensepoint XCD RTD cuts downtime and eliminates the need for specialized training.

Additional Features and Benefits: Reduce Cost of Ownership Over Life of the Product

  • Cut stocking and procurement costs with a common transmitter platform
  • Reduce maintenance time and expense with non-intrusive, one-person operation
  • Simplify maintenance with the plug-in, removable sensor
  • Reduce inspection and training time with tri-colour ‘traffic light’ display conveying safety status at a glance
  • Simplify setup and configuration with non-intrusive magnetic switches.

Gain Added Flexibility, Reliability and Performance.

  • Extend gas sensing element up to 100 feet (30 meters) from transmitter: mount in the most difficult to access areas.
  • Reduce the likelihood of human error via onboard diagnostics and easy-to-read display
  • Protect against dust/water ingress with IP66/67 rated stainless steel or aluminium enclosure
  • Prevent false alarms with auto-inhibit during maintenance
  • Select sink or source 4-20mA output: integral or remote configuration

Order Information

Transmitter Only

  • SPXCDASMTX4 XCD RTD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted 316SS
  • SPXCDALMTX4 XCD RTD Transmitter, 4 to 20 mA output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted LM25
  • SPXCDUSNTX4 XCD RTD Transmitter, 4 to 20 mA output, cCSAus, 3 x 3/4″ NPT entries, painted 316SS
  • SPXCDULNTX4 XCD RTD Transmitter, 4 to 20 mA output, cCSAus, 3 x 3/4″ NPT entries, painted LM25

With Modbus (Transmitter Only)

  • SPXCDASMTX4M XCD RTD Transmitter, 4 to 20 mA, Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted 316SS
  • SPXCDALMTX4M XCD RTD Transmitter, 4 to 20 mA, Modbus output, ATEX/IECEx, 2 x M20 entries, 1 x M25 entry, painted LM25
  • SPXCDUSNTX4M XCD RTD Transmitter, 4 to 20 mA, Modbus output, cCSAus, 3 x 3/4″ NPT entries, painted 316SS
  • SPXCDULNTX4M XCD RTD Transmitter, 4 to 20 mA, Modbus output, cCSAus, 3 x 3/4″ NPT entries, painted LM25

Accessories

  • 3KCAL Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors
  • SPXCDCC Collecting cone for use with lighter than air gases
  • SPXCDDMK Duct mounting kit
  • SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
  • SPXCDSDP Sunshade / Deluge Protection
  • 00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm 3 X 20mm Entries – ATEX Approved
  • 90068-A-8204 Gassing Block 316SST. 6mm O/D Connector to Sensor and 6mm Tube Connector to Gas Bottle
  • 90068-C-8290 PTFE Tubing 6mm O/D x 4mm I/D. Price per Meter
  • 90068-C-8291 PTFE Tubing 8mm O/D x 6mm I/D. Price per Meter
  • 90068-C-8292 Soft PVC Tubing 8mm O/D x 5mm I/D. Price per Meter
  • ADU300429 Adaptor, ATEX, Ex d e, 316SS, M20 (male) to 1/2″NPT (female)
  • RDU303029 Reducer, ATEX, Ex d e, 316SS, 3/4″NPT (male) to 1/2″NPT (female)
  • PDU300400 ATEX & CSAUS Marked, Ex d e, 316SS, IP66, M20 Blanking Plug
  • PDU303000 ATEX & CSAUS Marked, Ex d e, 316SS, IP66, 3/4″ NPT Blanking Plug
  • X4S-2006662 Field Device Tag Label (Based on Drawing Number 90084-C-7013). Material: 316 Stainless Steel

SPXCDULNO2 – Oxygen (O₂) 0–25% v/v, aluminium enclosure

SPXCDUSNO2 – Oxygen (O₂) 0–25% v/v, stainless steel enclosure

SPXCDULNO2M – Oxygen (O₂) 0–25% v/v, aluminium enclosure, Modbus

SPXCDUSNO2M – Oxygen (O₂) 0–25% v/v, stainless steel enclosure, Modbus

SPXCDULNH2 – Hydrogen Sulfide (H₂S) 0–50 ppm, aluminium enclosure

SPXCDUSNH2 – Hydrogen Sulfide (H₂S) 0–50 ppm, stainless steel enclosure

SPXCDULNH2M – Hydrogen Sulfide (H₂S) 0–50 ppm, aluminium enclosure, Modbus

SPXCDUSNH2M – Hydrogen Sulfide (H₂S) 0–50 ppm, stainless steel enclosure, Modbus

SPXCDULNC2 – Carbon Monoxide (CO) 0–200 ppm, aluminium enclosure

SPXCDUSNC2 – Carbon Monoxide (CO) 0–200 ppm, stainless steel enclosure

SPXCDULNC2M – Carbon Monoxide (CO) 0–200 ppm, aluminium enclosure, Modbus

SPXCDUSNC2M – Carbon Monoxide (CO) 0–200 ppm, stainless steel enclosure, Modbus

SPXCDULNG2 – Hydrogen (H₂) 0–1,000 ppm, aluminium enclosure

SPXCDUSNG2 – Hydrogen (H₂) 0–1,000 ppm, stainless steel enclosure

SPXCDULNG2M – Hydrogen (H₂) 0–1,000 ppm, aluminium enclosure, Modbus

SPXCDUSNG2M – Hydrogen (H₂) 0–1,000 ppm, stainless steel enclosure, Modbus

SPXCDULNN2 – Nitrogen Dioxide (NO₂) 0–10 ppm, aluminium enclosure

SPXCDUSNN2 – Nitrogen Dioxide (NO₂) 0–10 ppm, stainless steel enclosure

SPXCDULNN2M – Nitrogen Dioxide (NO₂) 0–10 ppm, aluminium enclosure, Modbus

SPXCDUSNN2M – Nitrogen Dioxide (NO₂) 0–10 ppm, stainless steel enclosure, Modbus

SPXCDULNA2 – Ammonia (NH₃) 0–50 ppm, aluminium enclosure

SPXCDUSNA2 – Ammonia (NH₃) 0–50 ppm, stainless steel enclosure

SPXCDULNA2M – Ammonia (NH₃) 0–50 ppm, aluminium enclosure, Modbus

SPXCDUSNA2M – Ammonia (NH₃) 0–50 ppm, stainless steel enclosure, Modbus

SPXCDULNL2 – Chlorine (Cl₂) 0–5 ppm, aluminium enclosure

SPXCDUSNL2 – Chlorine (Cl₂) 0–5 ppm, stainless steel enclosure

SPXCDULNL2M – Chlorine (Cl₂) 0–5 ppm, aluminium enclosure, Modbus

SPXCDUSNL2M – Chlorine (Cl₂) 0–5 ppm, stainless steel enclosure, Modbus

SPXCDULNS2 – Sulfur Dioxide (SO₂) 0–15 ppm, aluminium enclosure

SPXCDUSNS2 – Sulfur Dioxide (SO₂) 0–15 ppm, stainless steel enclosure

SPXCDULNS2M – Sulfur Dioxide (SO₂) 0–15 ppm, aluminium enclosure, Modbus

SPXCDUSNS2M – Sulfur Dioxide (SO₂) 0–15 ppm, stainless steel enclosure, Modbus

SPXCDULND2 – Nitric Oxide (NO) 0–100 ppm, aluminium enclosure

SPXCDUSND2 – Nitric Oxide (NO) 0–100 ppm, stainless steel enclosure

SPXCDULND2M – Nitric Oxide (NO) 0–100 ppm, aluminium enclosure, Modbus

SPXCDUSND2M – Nitric Oxide (NO) 0–100 ppm, stainless steel enclosure, Modbus

SPXCDULNO2R – Oxygen (O₂) 0–25%, aluminium enclosure with junction box

SPXCDUSNO2R – Oxygen (O₂) 0–25%, stainless steel enclosure with junction box

SPXCDULNO2RM – Oxygen (O₂) 0–25%, aluminium enclosure with junction box, Modbus

SPXCDUSNO2RM – Oxygen (O₂) 0–25%, stainless steel enclosure with junction box, Modbus

SPXCDULNH2R – Hydrogen Sulfide (H₂S) 0–50 ppm, aluminium enclosure with junction box

SPXCDUSNH2R – Hydrogen Sulfide (H₂S) 0–50 ppm, stainless steel enclosure with junction box

SPXCDULNH2RM – Hydrogen Sulfide (H₂S) 0–50 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSNH2RM – Hydrogen Sulfide (H₂S) 0–50 ppm, stainless steel enclosure with junction box, Modbus

SPXCDULNC2R – Carbon Monoxide (CO) 0–200 ppm, aluminium enclosure with junction box

SPXCDUSNC2R – Carbon Monoxide (CO) 0–200 ppm, stainless steel enclosure with junction box

SPXCDULNC2RM – Carbon Monoxide (CO) 0–200 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSNC2RM – Carbon Monoxide (CO) 0–200 ppm, stainless steel enclosure with junction box, Modbus

SPXCDULNG2R – Hydrogen (H₂) 0–1,000 ppm, aluminium enclosure with junction box

SPXCDUSNG2R – Hydrogen (H₂) 0–1,000 ppm, stainless steel enclosure with junction box

SPXCDULNG2RM – Hydrogen (H₂) 0–1,000 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSNG2RM – Hydrogen (H₂) 0–1,000 ppm, stainless steel enclosure with junction box, Modbus

SPXCDULNN2R – Nitrogen Dioxide (NO₂) 0–10 ppm, aluminium enclosure with junction box

SPXCDUSNN2R – Nitrogen Dioxide (NO₂) 0–10 ppm, stainless steel enclosure with junction box

SPXCDULNN2RM – Nitrogen Dioxide (NO₂) 0–10 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSNN2RM – Nitrogen Dioxide (NO₂) 0–10 ppm, stainless steel enclosure with junction box, Modbus

SPXCDULNA2R – Ammonia (NH₃) 0–50 ppm, aluminium enclosure with junction box

SPXCDUSNA2R – Ammonia (NH₃) 0–50 ppm, stainless steel enclosure with junction box

SPXCDULNA2RM – Ammonia (NH₃) 0–50 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSNA2RM – Ammonia (NH₃) 0–50 ppm, stainless steel enclosure with junction box, Modbus

SPXCDULNL2R – Chlorine (Cl₂) 0–5 ppm, aluminium enclosure with junction box

SPXCDUSNL2R – Chlorine (Cl₂) 0–5 ppm, stainless steel enclosure with junction box

SPXCDULNL2RM – Chlorine (Cl₂) 0–5 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSNL2RM – Chlorine (Cl₂) 0–5 ppm, stainless steel enclosure with junction box, Modbus

SPXCDULNS2R – Sulfur Dioxide (SO₂) 0–15 ppm, aluminium enclosure with junction box

SPXCDUSNS2R – Sulfur Dioxide (SO₂) 0–15 ppm, stainless steel enclosure with junction box

SPXCDULNS2RM – Sulfur Dioxide (SO₂) 0–15 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSNS2RM – Sulfur Dioxide (SO₂) 0–15 ppm, stainless steel enclosure with junction box, Modbus

SPXCDULND2R – Nitric Oxide (NO) 0–10 ppm, aluminium enclosure with junction box

SPXCDUSND2R – Nitric Oxide (NO) 0–10 ppm, stainless steel enclosure with junction box

SPXCDULND2RM – Nitric Oxide (NO) 0–10 ppm, aluminium enclosure with junction box, Modbus

SPXCDUSND2RM – Nitric Oxide (NO) 0–10 ppm, stainless steel enclosure with junction box, Modbus

Enquire About This Product

Get in touch with us to see how we can help you with your project

Thank you Message Sent
Error occurred while sending email. Please try again later.