Honeywell Sensepoint HT Flammable Sensor

  1. Home
  2. Products

Honeywell Sensepoint HT Flammable Sensor

The Sensepoint High-Temperature Sensor is designed to detect combustible gases in high-temperature, hazardous areas. Typical applications include turbine enclosures and drying ovens used in solvent-based printing and coating machines.

These applications require a sensor that provides reliable and stable detection and allows low-level alarm settings across a wide temperature range.

The Sensepoint High-Temperature Sensor uses a specially matched pair of Honeywell poison-resistant combustible gas detection elements. Its very stable baseline allows alarm trip points to be set as low as 5% LEL across a temperature range of -55°C to +150°C (-67°F to +302°F). Depending on the type of controller used, the gas measuring range can be configured from 0-20% LEL up to 0-100% LEL.

The detector elements are housed in an explosion-proof assembly and provide an industry-standard 3-wire mV bridge output, which can be connected to a suitable control device or converted to an analogue output signal via a field transmitter.

Excellent Performance

  • Certified for hazardous area operation up to +150°C (+302°F)
  • Alarm trip points as low as 5% LEL

Cost Effective

  • Low-cost disposable sensor
  • Greater than 5-year typical operating life

Reliable Operation

  • Thermally matched beads provide optimum accuracy and stability
  • Proven technology from the World leader in combustible gas detection

Flexibility

  • Measuring ranges from 0-20% LEL to 0-100% LEL
  • Wide range of accessories

Robust Construction

  • 316 Stainless Steel sensor body
  • ATEX/ IECEx approved design

Order Information

  • 2106B2310 Sensepoint HT Flammable Sensor (ATEX) M20
  • 2106B2311 Sensepoint HT Flammable Sensor (ATEX) M25
  • 2106B2312 Sensepoint HT Flammable Sensor (ATEX) 3/4 NPT

Note: For a complete sensor, order the correct number of FEEL EX e J.Box 2052D0001 and Weather Housing 00780-A-0076.

Parameter Specification
Range 0-20% LEL, 0-100% LEL (Control card dependent)
Speed of Response T60 Less than 6 seconds
T90 Less than 10 seconds
Minimum Alarm Level 5% LEL
Output Signal mV bridge
Operating Temperature -55°C to +150°C (-67°F to +302°F)
Operating Humidity Continuous: 20 to 90% RH
Intermittent: 10 to 99% RH
Operating Pressure 75 to 110kPa (750 to 1100mbar)
Stability (Zero) With time: Less than ±5% LEL / year
With temperature: Less than ±3% LEL
With humidity: Less than ±3% LEL
With pressure: Less than ±3% LEL
Stability (Span) With time: Less than ±5% LEL / year
With temperature: Less than ±4% LEL
With humidity: Less than ±3% LEL
With pressure: Less than ±3% LEL
Linearity Better than ±5% fsd
Repeatability Better than ±2% LEL
Warm-up Time 30 minutes
Detector Operating Life More than 5 years (typical)
Storage Life Typically, no degradation has been observed in clean, stable conditions for up to 5 years
Power Consumption 0.7W at 200mA
Enclosure Material 316 Stainless Steel
Mounting Thread M20, M25 or ¾″ NPT
Weight 225g (7.9oz)
Certification II 2 GD Ex d IIC T3 Gb Tamb -55°C to +150°C
tb IIIC T200ºC Db IP66 A21
Baseefa08ATEX0264X
IECEx BAS08.0069X