The General Monitors IR5500 is an open-path IR gas detector that continuously monitors hydrocarbon gas concentrations. The system consists of an IR source and receiver that continuously monitor light hydrocarbons in the 0 to 5000 ppm and 0 to 5 LEL meter ranges.
A meter with a 0 to 2000 ppm range and a 0 to 1 LEL range is also available for monitoring heavy hydrocarbons. The IR5500 provides two 4-20 mA analogue signals proportional to the above ranges, a digital display, and relay contacts.
The IR5500 is easily aligned using the digital display and adjustable mounting arms. Therefore, it does not require bulky setup equipment (e.g., digital voltmeters, handheld alignment aids).
The IR5500’s sensitivity can be checked by placing a test gas film in front of the receiver.
The IR5500 is factory-calibrated and does not require any additional calibration. It also requires minimal maintenance, aside from periodic visual inspections, a test gas film check, and window cleaning, to ensure dependable performance.
Sensor data and status information from the IR5500 can be transmitted up to 9,000 feet (2,743 m) to any industrial analogue-to-digital (A/D) converter for multipoint computer-based monitoring.
IR5500 receiver part number 329000. IR5500 transmitter (source) part number 329001.
| System Specifications | |
| Sensor Type | Infrared Absorption |
| Dual Ranges | |
| Methane | 0 to 5000 ppm• meter 0 to 5 LEL• meter |
| Propane | 0 to 2000 ppm• meter 0 to 1 LEL• meter |
| Other Gases | Consult factory for other hydrocarbon gases available |
| Path Lengths | 5-30 m, 20-100 m, 80-150 m |
| Response Time | T90 ≤ 3 s |
| Repeatability | ≤ ±5% |
| Linearity | ≤ ±5% of full scale for each scale or ±10% of applied gas, whichever is greater |
| Classification |
CSA/FM: Class I, Div 1 & 2, Groups B, C, & D; Class II, Div 1 & 2, Groups E, F, & G Class III; Type 4X |
| Haz Loc | T3C (Tamb=-60°C to +75°C) |
| Performance Verified |
ATEX/IECEx: II 2 G D, Ex d IIB+H2 T4 Gb Ex tb IIIC T135°C Db, IP66/67 (Tamb=-55°C to +65°C) |
| Calibration | No calibration required. Field background zero adjustment provided |
| Modes | Setup, alignment, test mode |
| Accessories | Test gas films, mounting arm, mounting base, scope, attenuation plate |
| Warranty | Two years |
| Approvals | CSA, FM, ATEX, IECEx, DNV-GL, INMETRO, EAC, CE. SIL 3 suitable. HART registered. |
| Mechanical Specifications | |
| Housing | 316 stainless steel |
| Source | 5.3″ dia. x 12.4″ length (135 mm dia. x 315 mm length) |
| Receiver | 5.3″ dia. x 12.4″ length (135 mm dia. x 315 mm length) |
| Weight |
Source: 12.20 lb. (5.53 kg) Receiver: 12.34 lb. (5.60 kg) |
| Conduit Entries (2) | ¾” NPT (standard), M25 (optional) |
| Environmental Specifications | |
| Operating Temperature Range | -67°F to +149°F (-55°C to +65°C) |
| Operating Humidity Range | 10-95% RH, non-condensing |
| Electrical Specifications | |
| Input Power |
20 to 36 VDC range, 24 VDC nominal 24 VDC @ 12 W (max.) – source 24 VDC @ 10 W (max.) – receiver (w/relays) Consult factory for lower power consumption options for other configurations |
| Relay Ratings |
8 A @ 250 VAC/8 A @ 30 VDC res. max. Four (4) SPDT – Fault; ppm Warning, LEL Warning; and Alarm |
| RS-485 Output | Modbus RTU with block and single data transfer modes |
| Baud Rate | 2400, 4800, 9600, 19200, or 38400 BPS |
| HART | Fully HART compliant |
| EMC Protection | Complies with EN 61000-6-4 and EN 50270 |
| Sample Cable Distances |
For cable resistance of 3 ohms/1,000 ft., maximum distance between IR5500 and power source @ 24 VDC: 14 AWG – 1,330 ft. (405 m) – receiver, 14 AWG – 1,040 ft. (317 m) – source. |
| Digital Display | LED indication of scale displayed; Two digit, seven segment (auto range change) |
| Standard Configuration |
IR5500-1-1-1-1-2-2-1-1-2-1 Methane, Dual 0-20 mA, HART, relays, mounting arm, 20-100 m path length |
| Notes |
* HART units can be configured to never output current less than 3.5 mA if the host equipment is incapable of working below this level. ** 0 to 2000 ppm• meter and 0 to 1 LEL• meter on propane unit. *** Using optional split range. |
Get in touch with us to see how we can help you with your project