Freedom 5000 transmitters provide a 4-20mA analogue output for the detection of Toxic and Oxygen gases. Gas readings can also be viewed locally on the TX display. Teledyne’s smart sensors transfer data such as gas type, range, and calibration information data to the universal electronics for automatic transmitter configuration. A missing sensor indicator alerts if there is no sensor or if not properly connected.
The built-in lithium battery keeps the sensor “hot,” which eliminates the need for sensor warm-up time. Onboard electronics enables users to easily zero and calibrate the sensor. An E-connector eliminates pin alignments and makes sensor replacement quick and easy.
With a two-wire loop-powered design and intrinsically safe housing, the product is easy to install and suitable for general industrial applications. The unique electrical design of the 5000 transmitter and sensor virtually eliminates false alarms due to RFI/EMI sources.
By combining advanced sensor technology with universal electronics and a common user interface across all configuration, Freedom 5000 helps users streamline the transmitter’s operation and maintenance requirements for its points of toxic gas detection.
The transmitter can be mounted directly to rigid conduit and is available with several optional adapters including wall/surface mount and a special “L” shaped bracket to allow mounting on top of flat surfaces such as gas cabinets.
Freedom series transmitters are also available with quick connect 1/4 turn sample draw and (flat or round) duct mount adapters. The sensor can be ordered integral to the transmitter or remote on three feet of cable, perfect for mounting the sensor near ground level while keeping the display at eye level.
Operating Freedom transmitters is simple and intuitive. After start-up, the transmitter automatically configures to the sensor’s parameters. Calibration is non-intrusive, performed by touching a magnet to the “Z” (zero), “S” (span), and up and down arrow markings on the enclosure. A programmable local inhibit feature and standard local display allows true one person calibration.
Ordering Information – Accessories & Spare Parts
Batteries, Backups, Chargers & Power Supplies
096-0719 – 24VDC Power Supply / Battery Backup
Remote Sensor End Caps & Accessories
074-0305 – 1/4 Turn Rain Shield
096-1943 – Sensor Rain Shield / Calibration Adaptor (uses SS End Cap 073-0165). Not for use with Rock Solid Sensors
096-1944 – FlowCell (old-style, fits over SS End Cap)
096-2101 – 1/4 Turn Calibration Adaptor
096-2102 – 1/4 Turn PVC Flowcell. Sold for transmitters equipped with remote sensors only
096-2105 – 1/4 Turn Sensor End Cap
096-2142 – Condensing RH Humishield End Cap
096-2273 – 1/4 Turn End Cap for ROCK SOLID Sensor
096-2276 – Condensing RH Humishield End Cap for ROCK SOLID Sensor
096-2741 – 5600 Hand-Held Display Assembly
Integral 5000 Endcaps & Adapters
073-0165 – End Cap, Stainless Steel. Sold for remote sensors only
073-0210 – Stainless Steel End Cap for ROCK SOLID. Sold for remote sensors only
074-0305 – 1/4 Turn Rain Shield
074-0357 – 1/4 Turn Sensor (NORYL) End Cap. Sold for Freedom 5000 transmitters equipped with integral sensors only
074-0389 – 1/4 Turn (NORYL) End Cap for ROCK SOLID Sensor. Freedom 5000 transmitters with integral sensors only
096-1943 – Rainshield / Calibration Adaptor for use with stainless steel endcap #073-0165. Allows remote gassing of sensor
096-1944 – Flowcell for use with stainless steel endcap. Sold for remote sensors only
096-2101 – 1/4 Turn Calibration Adaptor
096-2102 – 1/4 Turn PVC Flowcell. Sold for transmitters equipped with remote sensors only
096-2105 – 1/4 Turn Remote Sensor PVC End-Cap. Sold for remote Freedom 5000 sensors only
096-2669 – 1/4 Turn Noryl Flowcell. Sold for transmitters equipped with integral sensors only
096-2673 – End Cap (Noryl) for Condensing RH Humishield. Sold for transmitters equipped with integral sensors only
096-2674 – End Cap (Noryl) for Condensing RH Humishield and ROCK SOLID Sensor. For transmitters with integral sensors
Filters & Membranes
096-2104 – Dust Filter (H2S, O2 & CO only), Bag of 10
074-0331 – 4600 Teflon Sensor Spacer
Housing Enclosures
096-2671 – Enclosure with remote sensor fitting (does not include cable assembly)
096-2670 – Enclosure with sensor housing
Installation Accessories
096-2618 – Mounting Plate, Wall / Surface
Miscellaneous Spare Parts
009-0039 – Sensor Housing O-Ring
096-2002 – Sensor Housing Test Tool
093-0097 – E-Connector
096-2776 – Stainless Steel Tag (4 lines, 15 characters per line maximum)
069-0061 – Remote Sensor Cable
077-0120 – Magnetic Screwdriver
096-2619 – 5000 Remote Sensor Assembly (3 ft)
Sub-Assemblies & Electronics Spares
096-2613 – PCB Cable Assembly
096-2499 – I/O and Power Supply Board
096-2498-1 – CPU Board
096-2498 – CPU Board with SST
096-2497 – Display Board
Replacement Sensors
096-1965-0100 – Ammonia (NH3), Model 85, 0–100 PPM Standard Range
096-1965-0250 – Ammonia (NH3), Model 85, 0–250 PPM
096-1965-0300 – Ammonia (NH3), Model 85, 0–300 PPM
096-1965-0050 – Ammonia (NH3), Model 85, 0–50 PPM
096-1965-0500 – Ammonia (NH3), Model 85, 0–500 PPM
093-0536 – Carbon Dioxide (CO2), Freedom 6000 Infrared Sensor, 0–5%
096-1962-0050 – Carbon Monoxide (CO), Model 82, 0–50 PPM Standard Range
096-1962-0100 – Carbon Monoxide (CO), Model 82, 0–100 PPM Standard Range
096-1962-0250 – Carbon Monoxide (CO), Model 82, 0–250 PPM
096-1962-0500 – Carbon Monoxide (CO), Model 82, 0–500 PPM
096-1962-1000 – Carbon Monoxide (CO), Model 82, 0–1000 PPM
096-2315-0001 – Chlorine Dioxide (ClO2) ROCK SOLID, Model 78 (High RH), 0–1 PPM Standard Range
096-2315-0003 – Chlorine Dioxide (ClO2) ROCK SOLID, Model 78 (High RH), 0–3 PPM
096-2315-0005 – Chlorine Dioxide (ClO2) ROCK SOLID, Model 78 (High RH), 0–5 PPM
096-2247-0001 – Chlorine (Cl2) ROCK SOLID, Model 22 (Low RH), 0–1 PPM
096-2247-0005 – Chlorine (Cl2) ROCK SOLID, Model 22 (Low RH), 0–5 PPM
096-2247-0010 – Chlorine (Cl2) ROCK SOLID, Model 22 (Low RH), 0–10 PPM
096-2247-0020 – Chlorine (Cl2) ROCK SOLID, Model 22 (Low RH), 0–20 PPM
096-2295-0003 – Chlorine (Cl2) ROCK SOLID, Model 24 (High RH), 0–3 PPM
096-2295-0005 – Chlorine (Cl2) ROCK SOLID, Model 24 (High RH), 0–5 PPM Standard Range
096-2295-0010 – Chlorine (Cl2) ROCK SOLID, Model 24 (High RH), 0–10 PPM
096-2295-0020 – Chlorine (Cl2) ROCK SOLID, Model 24 (High RH), 0–20 PPM
096-2295-0030 – Chlorine (Cl2) ROCK SOLID, Model 24 (High RH), 0–30 PPM
096-2905-0010 – Ethylene Oxide (ETO), Model 15, 0–10 PPM
096-2846-0001 – Fluorine (F2) ROCK SOLID, Model 17 (Low RH), 0–1 PPM
096-2847-0003 – Fluorine (F2) ROCK SOLID, Model 18 (High RH), 0–3 PPM
096-2847-0005 – Fluorine (F2) ROCK SOLID, Model 18 (High RH), 0–5 PPM Standard Range
096-2334-0001 – Hydrogen Bromide (HBr) ROCK SOLID, Model 94 (Low RH), 0–1 PPM
096-2334-0005 – Hydrogen Bromide (HBr) ROCK SOLID, Model 94 (Low RH), 0–5 PPM
096-2335-0010 – Hydrogen Bromide (HBr) ROCK SOLID, Model 95 (High RH), 0–10 PPM
096-2335-0030 – Hydrogen Bromide (HBr) ROCK SOLID, Model 95 (High RH), 0–30 PPM
096-2332-0001 – Hydrogen Chloride (HCl) ROCK SOLID, Model 92 (Low RH), 0–1 PPM
096-2332-0010 – Hydrogen Chloride (HCl) ROCK SOLID, Model 92 (Low RH), 0–10 PPM Standard Range
096-2333-0010 – Hydrogen Chloride (HCl) ROCK SOLID, Model 93 (Standard RH >55%), 0–10 PPM Standard Range
096-2333-0025 – Hydrogen Chloride (HCl) ROCK SOLID, Model 93 (Standard RH >55%), 0–25 PPM
096-1952-0025 – Hydrogen Cyanide (HCN), Model 64, 0–25 PPM
096-1952-0100 – Hydrogen Cyanide (HCN), Model 64, 0–100 PPM
096-2330-0001 – Hydrogen Fluoride (HF) ROCK SOLID, Model 90 (Low RH <55%), 0–1 PPM
096-2330-0010 – Hydrogen Fluoride (HF) ROCK SOLID, Model 90 (Low RH <55%), 0–10 PPM
096-2331-0005 – Hydrogen Fluoride (HF) ROCK SOLID, Model 91 (RH >55%), 0–5 PPM
096-2331-0010 – Hydrogen Fluoride (HF) ROCK SOLID, Model 91 (RH >55%), 0–10 PPM
096-2331-0030 – Hydrogen Fluoride (HF) ROCK SOLID, Model 91 (RH >55%), 0–30 PPM
096-2751-0025 – Hydrogen Sulfide (H2S), Model 21 Special Low Methanol Sensitivity, 0–25 PPM
096-2751-0050 – Hydrogen Sulfide (H2S), Model 21 Special Low Methanol Sensitivity, 0–50 PPM
096-2751-0100 – Hydrogen Sulfide (H2S), Model 21 Special Low Methanol Sensitivity, 0–100 PPM
096-2751-0200 – Hydrogen Sulfide (H2S), Model 21 Special Low Methanol Sensitivity, 0–200 PPM
096-1959-0050 – Hydrogen Sulfide (H2S), Model 72 (Low RH), 0–50 PPM Standard Range
096-1959-0100 – Hydrogen Sulfide (H2S), Model 72 (Low RH), 0–100 PPM
096-1961-0025 – Hydrogen Sulfide (H2S), Model 81 (High RH), 0–25 PPM
096-1961-0050 – Hydrogen Sulfide (H2S), Model 81 (High RH), 0–50 PPM Standard Range
096-1961-0100 – Hydrogen Sulfide (H2S), Model 81 (High RH), 0–100 PPM
096-1961-0200 – Hydrogen Sulfide (H2S), Model 81 (High RH), 0–200 PPM
096-1964-0010 – Nitrogen Dioxide (NO2), Model 84, 0–10 PPM Standard Range
096-2809-0010 – Nitrogen Trifluoride (NF3) ROCK SOLID, Model 33P, 0–10 PPM
096-1960-0010 – Oxygen (O2), Model 80, 0–10%
096-1960-0025 – Oxygen (O2), Model 80, 0–25% Standard Range
096-2377-0001 – Ozone (O3) ROCK SOLID, Model 76 (Low RH <55%), 0–1 PPM Standard Range
096-2378-0001 – Ozone (O3) ROCK SOLID, Model 77 (RH >55%), 0–1 PPM Standard Range
096-1956-1000 – Silane (SiH4), Model 68, 1000 PPB Standard Range
096-1956-0010 – Silane (SiH4), Model 68, 0–10 PPM
096-1963-0010 – Sulfur Dioxide (SO2), Model 83 (High RH), 0–10 PPM
096-1963-0050 – Sulfur Dioxide (SO2), Model 83 (High RH), 0–50 PPM
096-1963-0100 – Sulfur Dioxide (SO2), Model 83 (High RH), 0–100 PPM
096-1963-0500 – Sulfur Dioxide (SO2), Model 83 (High RH), 0–500 PPM
096-2359-0100 – Sulfur Dioxide (SO2), Model 75 (Low RH), 0–100 PPM
096-2336-0001 – Sulfur Dioxide ROCK SOLID, Model 96 (Low RH), 0–1 PPM
096-2336-0003 – Sulfur Dioxide ROCK SOLID, Model 96 (Low RH), 0–3 PPM
096-2336-0010 – Sulfur Dioxide ROCK SOLID, Model 96 (Low RH), 0–10 PPM Standard Range
096-2337-0001 – Sulfur Dioxide ROCK SOLID, Model 97 (High RH), 0–1 PPM
096-2337-0010 – Sulfur Dioxide ROCK SOLID, Model 97 (High RH), 0–10 PPM Standard Range
096-2337-0025 – Sulfur Dioxide ROCK SOLID, Model 97 (High RH), 0–25 PPM
Get in touch with us to see how we can help you with your project