Now obsolete replacement here.
The Drager Polytron Pulsar 2 is a fixed gas open path detector for flammable gases using a transmitter and receiver. The infrared beam is transmitted to the receiver, and the resulting IR absorption signal loss determines the gas reading. Explosion-proof, it can be used in hazardous zone areas. As standard, it detects Methane or Propane as selected by the user, ranging from 0 to 4 up to 0 to 8 LEL m. Dependent on the size of the area, a range of different transmitters are provided; 4 to 60 m, 30 to 120 m or 100 to 200 m (13 to 197 ft, 98 to 394 ft or 328 to 656 ft).
An alignment kit containing a handheld terminal, test cards, and software is available to align to the transmitter and receiver correctly. Once aligned, automated zeroing of gas completes the install. Manual aligning or gas testing is not required. The 4-20mA output variation indicates fault detection. Under 1mA out means the beam is blocked or hardware fault. 2mA identifies a recent beam block that will fault if blockage time exceeds one hour. A 3.5mA output indicates misalignment or dirt interference, a pre-warning signal to schedule maintenance, monitoring will still be operational.
The Polytron Pulsar 2 adapts to changing environmental conditions to ensure system integrity to maintain accuracy. The receiver logs gas readings, signal strength/blocks and temperature for up to a week. A condensed version is stored for up to a month. Heated optics combat the cold. The receiver instructs the transmitter digitally to increase the flash rate in the wake of interference or on gas detection. Resistant to sunlight, so it can be used in the desert and is also immune to flare stacks, so it is ideal for oil and gas applications.
Hart communication allows digital access to the Pulsar outside hazardous areas.
Equipped with all the same functions as the standard Drager Pulsar, Pulsar 2 is fitted with an ABS moulded cover and is supplied with either a junction box or certified connector to provide complete flexibility during installation.
GD8/2
Polytron Pulsar 2 with ABS moulded cover and EEx e certified junction box
Polytron Pulsar 2 with ABS moulded cover and EEx d certified plug and socket connectors
Accessories
Past Part Numbers
Monitor
8328030 – Dräger Polytron 8900 UGLD d S, 4-20mA/HART output with 3 relays, stainless steel Ex d housing.
Accessories
4544101 – Magnetic Wand
8328021 – Remote Sensing Head with wall mount kit
Connecting Cable with Plug for Remote Sensing Head
Get in touch with us to see how we can help you with your project