Drager Polytron IR is obsolete; the equivalents are PIR 7000, Polytron 5700 and Polytron 8700.
The Polytron IR was a permanent gas detector for monitoring combustible gases using an Infrared sensor. Two choices were available: type 340, which opened the door to new applications picking up alkanes and cyclohexane. Configurable from 5 to 100 %LEL. Or secondly, type 334 measuring 0 to 20 %LEL and up to 100 %LEL, alternatively 0 to 100 %v/v for methane. The IR sensor had a longer life span and was robust, allowing use in harsh conditions such as offshore. Little maintenance was required, and drift-free was less than 2% LEL.
The detector sent a 2 mA signal to the controller in the event of dirty optics, allowing preventive measures and continued readings before a block beam signal at less than 1mA was generated. Normal output signal 4-20mA. HART and RS485 digital outputs were provided.
Those currently in operation are permitted for use in hazardous areas and have the following approvals UL, CSA Class 1, Div 1, Groups B, C, D, and ATEX.
Polytron IR Part Numbers
Monitor
8328030 – Dräger Polytron 8900 UGLD d S, 4-20mA/HART output with 3 relays, stainless steel Ex d housing.
Accessories
4544101 – Magnetic Wand
8328021 – Remote Sensing Head with wall mount kit
Connecting Cable with Plug for Remote Sensing Head