The Detcon TP-700 by Teledyne is a non-intrusive, “Smart” sensor designed to detect and monitor H2S in the air over a 0-100 ppm range, utilising proprietary solid-state metal oxide semiconductor technology. The plug-in, field-replaceable detector features oversized gold-plated connections that help prevent corrosion.
The TP-700’s rugged framework features an electro-polished 316 stainless steel housing, fully encapsulated electronics, and dual-layer surge protection. This innovative design eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display.
The Model TP-700 has standard analogue 4-20mA and Modbus RS-485 outputs. Its unique feature is a wireless option that can be used with Detcon’s SmartWireless product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s solid-state MOS H2S gas sensor has an infinite shelf life and a 10-year conditional warranty.
Applications include oil and Gas drilling and production sites, Refining and Petrochemical facilities, Pulp and Paper Mills, and Wastewater Treatment Plants.
| Part Number | Description |
|---|---|
| 967-015520-100 | TP-700 Solid State MOS H2S Sensor Assembly (no condulet) |
| 967-011520-100 | TP-700 Solid State MOS H2S Gas Sensor Assembly (aluminium condulet) |
| 967-014520-100 | TP-700 Solid State MOS H2S Gas Sensor Assembly (316SS condulet) |
| 9H7-011520-100 | TP-700 MOS H2S Gas Sensor with HART bridge Assembly (aluminium condulet) |
| 9H7-014520-100 | TP-700 MOS H2S Gas Sensor with HART bridge Assembly (316SS condulet) |
| 9R7-011520-100 | TP-700 MOS H2S Gas Sensor with RAM Assembly (aluminium condulet) |
| 9R7-014520-100 | TP-700 MOS H2S Gas Sensor with RAM Assembly (316SS condulet) |
| 9K7-011520-100 | TP-700 MOS H2S Gas Sensor with HART-RAM Assembly (aluminium condulet) |
| 9K7-014520-100 | TP-700 MOS H2S Gas Sensor with HART-RAM Assembly (316SS condulet) |
Certification: Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
| Part Number | Description |
|---|---|
| 975-70000A-00A | Remote Control / Alarm Relay Module in Aluminium Enclosure |
| 975-70000A-00S | Remote Control / Alarm Relay Module in 316SS Enclosure |
| 975-70000H-00A | Remote Control / Alarm Relay Module with HART in Aluminium Enclosure |
| 975-70000H-00S | Remote Control / Alarm Relay Module with HART in 316SS Enclosure |
| 975-70005H-00A | HART Integration Module in Aluminium Enclosure |
| 975-70005H-00S | HART Integration Module in 316SS Enclosure |
| System Specifications | |
|---|---|
| Sensor Type |
Continuous diffusion/adsorption CHEMFET Solid State Metal Oxide
Semiconductor sensor. Plug-in, field-replaceable design. |
| Sensor Life | 5 to 10 years typical. |
| Measurement Range | 0–20 ppm, 0–50 ppm, 0–100 ppm. |
| Accuracy / Repeatability | ±10% of reading or ±2 ppm (whichever is greater). |
| Response / Clearing Time | T50 < 30 seconds; T80 < 60 seconds. |
| Outputs |
Linear 4-20 mA DC RS-485 Modbus RTU |
| Electrical Classification |
CSA & US (NRTL): Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H₂ ATEX: II 2 G Ex d IIB + H₂ T4 Gb (Tamb = -40°C to +70°C) |
| Ingress Protection | NEMA 4X, IP66. |
| Safety Approvals |
cCSAus Complies with ISA 92.01 Part 1-1998 (Performance Requirements for H₂S) ATEX CE Marking SIL2 Certified to IEC 61508 |
| Warranty |
Plug-in Detector – 10-Year Conditional Warranty Transmitter – 2 Years |
| Environmental Specifications | |
| Operating Temperature Range | -40°F to +167°F (-40°C to +75°C). |
| Storage Temperature Range | -31°F to +131°F (-35°C to +55°C). |
| Operating Humidity Range | 5–100% RH non-condensing. |
| Operating Pressure Range | Atmospheric ±10%. |
| Mechanical Specifications | |
| Dimensions |
Sensor Assembly: 7" H × 2.2" Dia. (178 mm H × 65 mm Dia.) With Junction Box: 11" H × 6.1" W × 3.75" D (280 mm H × 155 mm W × 96 mm D) Mounting Hole Centres (J-Box): 5.5" (140 mm) |
| Weight |
Sensor Only: 2 lbs (0.907 kg) With Aluminum Junction Box: 6 lbs (2.72 kg) With Stainless Steel Junction Box: 9 lbs (4.08 kg) |
| Electrical Specifications | |
| Power Input | 11–30 VDC. |
| Power Consumption |
Normal Operation: 68 mA (<1.7 Watts) Maximum: 85 mA (2 Watts) |
| Inrush Current | 1.0 A @ 24 VDC. |
| RFI / EMI Protection | Complies with EN50270. |
| Analog Output |
Linear 4–20 mA DC (1,000 Ω maximum loop load @ 24 VDC) 0 mA – All Fault Diagnostics 2 mA – Calibration Mode 4–20 mA – 0–100% Full Scale 22 mA – Over-range Condition |
| Serial RS-485 Output | RS-485 Modbus™ RTU. |
| Baud Rate | 9600 BPS (9600, N, 8, 1 Half Duplex). |
| Status Indicators |
4-digit LED display with gas concentration. Full-script menu prompts for AutoSpan, Setup Options, and Fault Reporting. |
| Faults Monitored | Heater, Loop, Input Voltage, Sensor, Processor, Memory, and Calibration. |
| Cable Requirements |
Power / Analog: 3-wire shielded cable. Maximum distance: 13,300 ft using 14 AWG cable. Serial Output: 2-wire twisted-pair shielded cable specifically for RS-485 installations. Maximum distance: 4,000 ft to the last sensor. |
| I/O Protection | Over-voltage protection, miswiring protection, and EMI/RFI immunity. |
Get in touch with us to see how we can help you with your project