The Detcon PI-700 by Teledyne is a non-intrusive “Smart” sensor that uses photo-ionisation detector technology to monitor VOC gases over ranges from 0-10 ppm to 0-5,000 ppm. The PI-700 are the low-range models, and the PI-701 are the high-range versions. In the sensor design, Detcon has successfully converted the sensitive laboratory-style PID technology into a rugged, environmentally insensitive, and long-life industrial gas sensor. The plug-in, field-replaceable detector features oversized gold-plated connections that help prevent corrosion.
The PI-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual-layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model PI-700 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display.
The Model PI-700 is equipped with standard analogue 4-20mA and Modbus RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s PID sensors have a long shelf life and are supported by an industry-leading warranty.
Applications: Pharmaceutical industry, Power plants, Chemical industry, Air quality, Refineries and petrochemical plants, Solvent recovery systems, Wastewater treatment plants, Marine and offshore oil wells, Pulp and paper manufacturing, Painting and coating operations.
| Part Number | Description |
|---|---|
| 967-PB5520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor Assembly (no condulet) |
| 967-PB1520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor Assembly (aluminium condulet) |
| 967-PB4520-010 | PI-700-VOC Volatile Organic Compound Gas Sensor Assembly (316SS condulet) |
| 9H7-PB1520-010 | PI-700-VOC Gas Sensor with HART bridge Assembly (aluminium condulet) |
| 9H7-PB4520-010 | PI-700-VOC Gas Sensor with HART bridge Assembly (316SS condulet) |
| 9R7-PB1520-010 | PI-700-VOC Gas Sensor with RAM Assembly (aluminium condulet) |
| 9R7-PB4520-010 | PI-700-VOC Gas Sensor with RAM Assembly (316SS condulet) |
| 9K7-PB1520-010 | PI-700-VOC Gas Sensor with HART-RAM Assembly (aluminium condulet) |
| 9K7-PB4520-010 | PI-700-VOC Gas Sensor with HART-RAM Assembly (316SS condulet) |
| Part Number | Description |
|---|---|
| 967-PM5520-01K | PI-701-VOC Volatile Organic Compound Sensor Assembly |
| 967-PM1520-01K | PI-701-VOC Gas Sensor Assembly (aluminium condulet) |
| 967-PM4520-01K | PI-701-VOC Gas Sensor Assembly (316SS condulet) |
| 9H7-PM1520-01K | PI-701-VOC Gas Sensor with HART bridge Assembly (aluminium condulet) |
| 9H7-PM4520-01K | PI-701-VOC Gas Sensor with HART bridge Assembly (316SS condulet) |
| 9R7-PM1520-01K | PI-701-VOC Gas Sensor with RAM Assembly (aluminium condulet) |
| 9R7-PM4520-01K | PI-701-VOC Gas Sensor with RAM Assembly (316SS condulet) |
| 9K7-PM1520-01K | PI-701-VOC Gas Sensor with HART-RAM Assembly (aluminium condulet) |
| 9K7-PM4520-01K | PI-701-VOC Gas Sensor with HART-RAM Assembly (316SS condulet) |
| System Specifications | |
|---|---|
| Sensor Type | Continuous diffusion/adsorption Photo Ionisation Detector (PID), plug-in replaceable intelligent type with replacement lamp. |
| Sensor Life | 2 years typical. |
| Measurement Range | Gas dependent, ranges as low as 0–10 ppm or as high as 0–5,000 ppm. |
| Accuracy / Repeatability | ±10% of reading or ±2% of range (whichever is greater). |
| Response Time | T50 < 30 seconds; T90 < 60 seconds. |
| Outputs |
Linear 4-20 mA DC RS-485 Modbus RTU |
| Electrical Classification |
cCSAus: Class I, Division 1, Groups B, C, D (Tamb = -20°C to +50°C) Class I, Zone 1, Group IIB+H₂ ATEX: II 2 G Ex d ib IIB + H₂ T4 Gb (Tamb = -20°C to +50°C) |
| Ingress Protection | NEMA 4X, IP66. |
| Safety Approvals | cCSAus, ATEX, CE Marking. |
| Warranty |
Plug-in Detector: 1 Year Transmitter: 2 Years |
| Environmental Specifications | |
| Operating Temperature Range | -4°F to +122°F (-20°C to +50°C). |
| Storage Temperature Range | -4°F to +122°F (-20°C to +50°C). |
| Operating Humidity Range | 0–100% RH non-condensing. |
| Mechanical Specifications | |
| Dimensions |
Sensor Assembly: 7" H × 2.2" Dia. (178 mm H × 65 mm Dia.) With Junction Box: 11" H × 6.1" W × 3.75" D (280 mm H × 155 mm W × 96 mm D) Mounting Hole Centres (J-Box): 5.5" (140 mm) |
| Weight |
Sensor Only: 2 lbs (0.907 kg) With Aluminum Junction Box: 6 lbs (2.72 kg) With Stainless Steel Junction Box: 9 lbs (4.08 kg) |
| Electrical Specifications | |
| Power Input | 11–30 VDC. |
| Power Consumption | Maximum 65 mA (1.6 Watts). |
| Inrush Current | 1.67 A @ 24 VDC. |
| RFI / EMI Protection | Complies with EN50270. |
| Analog Output |
Linear 4–20 mA DC (1,000 Ω maximum loop load @ 24 VDC) 0 mA – Fault Diagnostics 2 mA – Calibration Mode 4–20 mA – 0–100% Full Scale 22 mA – Over-range Condition |
| Serial RS-485 Output | RS-485 Modbus™ RTU. |
| Baud Rate | 9600 BPS (9600, N, 8, 1 Half Duplex). |
| Status Indicators |
4-digit LED display showing gas concentration. Full-script menu prompts for AutoSpan, Setup Options and Fault Reporting. |
| Faults Monitored | Loop, Input Voltage, Zero, Missing Sensor, Processor, Memory and Calibration. |
| Cable Requirements |
Power / Analog: 3-wire shielded cable. Maximum distance: 13,300 ft using 14 AWG cable. Serial Output: 2-wire twisted-pair shielded cable designed for RS-485 installations. Maximum distance: 4,000 ft to last sensor. |
| I/O Protection | Over-voltage protection, miswiring protection, and EMI/RFI immunity. |