Detcon Model TP-624D

  1. Home
  2. Products

Detcon Model TP-624D

The Detcon model TP-624D by Teledyne is a “Smart” gas detection sensor designed to detect and monitor H2S in the air over the ranges of 0-20 ppm, 0-50 ppm, and 0-100 ppm using a proprietary solid-state metal oxide semiconductor technology. This innovative design offers several advantages, including longer sensor life and better temperature and humidity performance.

Model TP-624D features Detcon’s MicroSafe intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in a stainless steel housing, a base connector board, an explosion-proof enclosure (available in aluminium or stainless steel), a plug-in control transmitter circuit, and a splashguard with an integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D).

Equipped with a standard analogue 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, one-person remote calibration, self-adjusting zero and span, and LED indicators for two alarm relays and one fault relay and calibration status.

Features

  • cCSAus approved for Class I, Division 1, Groups B, C, & D Transmitter design fits all existing Detcon MOS H2S sensors dating back 20 years.
  • Compatible with PLCs, SCADA, DCS, via 0-20 mA, and/or RS-485, and/or alarm relays.
  • Sensor status and parameters are accessible via RS-485 (Modbus).
  • Menu programmable relays standard (two alarms plus fault).
  • Simple menu-driven calibration- less than 3 minutes.
  • LED display and LED indicators for FAULT and CAL status.
  • Plug-in field-replaceable transmitter.
  • Response similar to electrochemical sensor: T50 less than 30sec., T80 greater than 60 sec.
  • Direct response constant temperature control.
  • Withstands exposure to high-range concentrations of H2S and other acid gases.
  • Impervious to high moisture environments in both powered and non-powered modes.
  • Extensive Fault diagnostics.
  • Replaces model TP-624C.

Applications

  • Oil and Gas Drilling Rigs
  • Oil and Gas Production Sites
  • Refining and Petrochemical
  • Pulp and Paper Mills
  • Waste Water Treatment Plants

TP-624 Series MOS Hydrogen Sulfide Gas Detection Sensor Assemblies

Sensor Assemblies

Part Number Description
966-014520-100 TP-624D Solid State MOS H2S Sensor Assembly Alum Condulet
966-01452B-100 TP-624D-316SS Solid State MOS H2S Sensor Assembly 316SS Condulet

Accessories

Part Number Description
943-000000-000 Calibration Sleeve / Wind Guard (for use with splash guard)
960-202200-000 Condensation prevention packet (replace annually)
437-500000-000 Stainless steel tag
943-004223-000 2″ pipe mount with sun shade
943-004221-000 Sensor Mounting Plate for 2″ pipe
943-002273-000 Harsh location dust guard (fits 1.5 x 18 thread)
033-003238-000 Replacement filter for dust guard (pack of 20)
943-002274-000 Hazardous location dust guard (7/8) for TP series sensors
943-003236-000 Replacement filter for harsh location dust guard (pack of 20)
943-003436-000 Harsh location water guard (fits standard splash guards)
897-850000-010 Aluminum junction box with solid lid
897-850901-010 Aluminum junction box with lens cover
897-850000-316 Stainless steel junction box with solid cover
897-850901-316 Stainless steel junction box with lens cover
943-121747-SS5 Stainless steel flow-through adapter
Sensor Type Continuous Diffusion/Adsorption, CHEMFET Solid State Metal Oxide Semiconductor
Sensor Life 5 to 10 Years Typical
Measurement Range 0–20 ppm, 0–50 ppm, 0–100 ppm
Accuracy / Repeatability ±10% of Reading or ±2 ppm (Whichever is Greater)
Response / Clearing Time T50 < 30 Seconds; T80 < 60 Seconds
Outputs Linear 4–20 mA DC
RS-485 Modbus RTU
3 Relays (Alarm 1, Alarm 2 & Fault)
Contacts Rated 5 A
Electrical Classification Explosion Proof

CSAus: Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C)
Class I, Zone 1, Group IIB+H2

cCSA: Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C)
Class I, Zone 1, Group IIB+H2

ATEX: Ex d IIB+H2 T4 (Tamb = -40°C to +60°C)
Safety Approvals cCSAus
ATEX
CE Marking
SIL 2 FMEDA Rating
Ingress Protection IP66
Warranty Plug-in Detector: 10-Year Conditional Warranty
Transmitter: 2-Year Warranty
Operating Temperature Range Canada: -40°C to +40°C (-40°F to 104°F)
USA: -25°C to +40°C (-13°F to 104°F)
Storage Temperature Range -35°C to +55°C (-31°F to +131°F)
Operating Humidity Range 5–100% RH, Non-condensing
Operating Pressure Range Atmospheric ±10%
Dimensions 254 × 155 × 109 mm (H × W × D)
10" × 6.1" × 4.3" (Including Splashguard)
Mounting Holes (J-Box) 140 mm (5.5") Center-to-Center
Weight 2.72 kg (6 lbs) with Aluminum J-Box
4.08 kg (9 lbs) with Stainless Steel J-Box
Power Input 22–28 VDC*
*12 VDC Available by Special Order
Power Consumption Normal Operation: 68 mA (<1.7 W)
Maximum: 85 mA (2 W)
RFI / EMI Protection Complies with EN 50270
Analog Output Linear 4–20 mA DC (1,000 Ω Max Loop Load @ 24 VDC)
0 mA – All Fault Diagnostics
2 mA – In Calibration
4–20 mA – 0–100% Full Scale
22 mA – Over-range Condition
Serial RS-485 Output RS-485 Modbus™ RTU
Baud Rate 9600 BPS (9600, N, 8, 1 Half Duplex)
Status Indicators 4-Digit LED Display with Gas Concentration
Full-Script Menu Prompts for AutoSpan, Setup Options & Fault Reporting
LEDs for Alarm 1, Alarm 2, Fault & Calibration
Relay Outputs Alarm 1, Alarm 2 & Fault
5 A @ 250 VAC
5 A @ 30 VDC
Faults Monitored Heater, Loop, Input Voltage,
Sensor, Processor, Memory, Calibration
Cable Requirements Power / Analog: 3-Wire Shielded Cable
Maximum Distance: 13,300 ft (4,054 m) with 14 AWG
Serial Output Cabling 2-Wire Twisted-Pair Shielded Cable for RS-485 Installations
Maximum Distance: 4,000 ft (1,219 m) to Last Sensor
I/O Protection Over-voltage, Miswiring, EMI/RFI Immunity