The Detcon FP-700 by Teledyne is a non-intrusive, “Smart” sensor designed to detect and monitor combustible gases in the air over the range of 0-100% LEL, utilising catalytic bead sensor technology. The plug-in, field-replaceable detector is poison-resistant and features oversized gold-plated connections that help prevent corrosion.
The FP-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual-layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes.
A primary feature of the Model FP-700 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model FP-700 is equipped with standard analogue 4-20mA and Modbus RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless product line. Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s combustible gas sensor has an infinite shelf life and a 2-year warranty.
Suitable for Oil and Gas, FPSOs, LNG/CNG Plants, Refining and Petrochemical, Pulp and Paper Mills and Waste Water Treatment Plants.
| Part Number | Description |
|---|---|
| 967-525520-100 | FP-700 Catalytic LEL Gas Sensor Assembly (No Condulet) |
| 967-521520-100 | FP-700 Catalytic LEL Gas Sensor Assembly (Aluminium Condulet) |
| 967-524520-100 | FP-700 Catalytic LEL Gas Sensor Assembly (316SS Condulet) |
| 9H7-521520-100 | FP-700 Catalytic LEL Gas Sensor with HART Bridge (Aluminium Condulet) |
| 9H7-524520-100 | FP-700 Catalytic LEL Gas Sensor with HART Bridge (316SS Condulet) |
| 9R7-521520-100 | FP-700 Catalytic LEL Gas Sensor with RAM (Aluminium Condulet) |
| 9R7-524520-100 | FP-700 Catalytic LEL Gas Sensor with RAM (316SS Condulet) |
| 9K7-521520-100 | FP-700 Catalytic LEL Gas Sensor with HART + RAM (Aluminium Condulet) |
| 9K7-524520-100 | FP-700 Catalytic LEL Gas Sensor with HART + RAM (316SS Condulet) |
Classification: Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
| Part Number | Description |
|---|---|
| 975-70000A-00A | Remote Control / Alarm Relay Module (Aluminium Enclosure) |
| 975-70000A-00S | Remote Control / Alarm Relay Module (316SS Enclosure) |
| 975-70000H-00A | Remote Control / Alarm Relay Module with HART (Aluminium Enclosure) |
| 975-70000H-00S | Remote Control / Alarm Relay Module with HART (316SS Enclosure) |
| 975-70005H-00A | HART Integration Module (Aluminium Enclosure) |
| 975-70005H-00S | HART Integration Module (316SS Enclosure) |
| System Specifications | |
|---|---|
| Sensor Type |
Continuous diffusion/adsorption Matched-pair catalytic bead detector Plug-in field replaceable |
| Sensor Life | 3 to 5 years typical |
| Measurement Range | 0-100% LEL (Lower Explosive Limit) |
| Accuracy / Repeatability | ±3% (0-50% LEL); ±5% (50-100% LEL) |
| Response / Clearing Time | T50 < 10 seconds; T90 < 30 seconds |
| Zero Drift | <5% per year |
| Outputs |
Linear 4-20 mA DC RS-485 MODBUS-RTU |
| Electrical Classification |
Explosion Proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C) Class I, Zone 1, Group IIB+H2 ATEX II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) |
| Ingress Protection | NEMA 4X, IP66 |
| Safety Approvals |
cCSAus Performance to ANSI/ISA 60079-29-1 (12.13.01)-2013 and CSA 22.2 #152 ATEX CE Marking SIL2 Certified to IEC 61508 |
| Warranty |
Plug-in Detector – 2 Years Transmitter – 2 Years |
| Environmental Specifications | |
| Operating Temperature Range | -40°F to +167°F (-40°C to +75°C) |
| Storage Temperature Range | -40°F to +167°F (-40°C to +75°C) |
| Operating Humidity Range | 0-99% RH non-condensing |
| Mechanical Specifications | |
| Dimensions |
7”H × 2.2” Dia. (178mm × 65mm) – Sensor Assembly Only 11”H × 6.1”W × 3.75”D (280mm × 155mm × 96mm) – With Junction Box Mounting Holes (J-Box): 5.5” (140mm) Centre-to-Centre |
| Weight |
2 lbs (0.907kg) – Sensor Only 6 lbs (2.72kg) – With Aluminum Junction Box 9 lbs (4.08kg) – With Stainless Steel Junction Box |
| Electrical Specifications | |
| Power Input | 11-30 VDC |
| Power Consumption |
Normal Operation = 68mA (<1.7W) Maximum = 85mA (2W) |
| Inrush Current | 1.0A @ 24V |
| RFI/EMI Protection | Complies with EN50270 |
| Analog Output |
Linear 4-20mA DC (1,000Ω max loop load @ 24VDC) 0mA – All Fault Diagnostics 2mA – In Calibration 4-20mA – 0-100% Full Scale 22mA – Over-range Condition |
| Serial RS-485 Output | RS-485 Modbus™ RTU |
| Baud Rate | 9600 BPS (9600, N, 8, 1 Half Duplex) |
| Status Indicators |
4-digit LED Display with Gas Concentration Full-script Menu Prompts for AutoSpan, Set-up Options, and Fault Reporting |
| Faults Monitored | Operating Temperature, Loop, Input Voltage, Bridge Voltage, Zero, Sensor, Processor, Memory, Calibration |
| Cable Requirements |
Power/Analog: 3-wire shielded cable Maximum distance: 13,300 feet with 14 AWG Serial Output: 2-wire twisted-pair shielded cable specifically for RS-485 installations Maximum distance: 4,000 feet to last sensor |
| I/O Protection | Over-voltage, Miswiring, EMI/RFI Immunity |