The Detcon DM-700 by Teledyne is a non-intrusive “Smart” sensor designed to detect Toxic Gases in the air using electrochemical sensor technology.
The intelligent plug-in, field-replaceable cell automatically recognises the gas type and range and features oversized gold-plated connections that help prevent corrosion.
The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual-layer surge protection.
This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes.
A primary feature of the Model 700 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display.
The Model 700 is equipped with standard analogue 4-20mA and Modbus RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless product line. Additional integration options include a Remote Alarm Module (RAM) and HART.
Detcon’s toxic gas sensors have a long shelf life and an industry-leading warranty. Models for H2S gas are available.
Applications: Oil & Gas, Chemical Plants, Food & Beverage, Steel Mills, Pulp and Paper, Refineries, Wastewater Treatment Plants and Utilities.
| Part Number | Description |
|---|---|
| 967-12EG90-100 | DM-700-C2H2 Acetylene Sensor Assembly (Available with Flying Leads only) |
| 967-505090-100 | DM-702-NH3 Ammonia Sensor Assembly |
| 967-191990-001 | DM-700-AsH3 Arsine Sensor Assembly |
| 967-747590-010 | DM-700-Br2 Bromine Sensor Assembly |
| 967-12EB90-100 | DM-700-C4H6 Butadiene Sensor Assembly |
| 967-444490-100 | DM-700-CO Carbon Monoxide Sensor Assembly |
| 9R7-444491-100 | DM-700-CO Carbon Monoxide Sensor Assembly with Remote Control / Alarm Relay Module |
| 967-747490-010 | DM-700-CL2 Chlorine Sensor Assembly |
| 967-777790-001 | DM-701-CLO2 Chlorine Dioxide Sensor Assembly (0–1 ppm) |
| 967-747690-050 | DM-700-CLO2 Chlorine Dioxide Sensor Assembly (0–50 ppm) |
| 967-192190-001 | DM-700-B2H6 Diborane Sensor Assembly |
| 967-192190-005 | DM-700-B2H6 Diborane Sensor Assembly (Replaced by 967-192190-001) |
| 967-12EO90-100 | DM-700-C2H5OH Ethanol Sensor Assembly |
| 967-24EZ90-100 | DM-700-C2H5SH Ethyl Mercaptans Sensor Assembly |
| 967-12ED90-100 | DM-700-C2H4 Ethylene Sensor Assembly |
| 967-12EJ90-100 | DM-700-C2H4O Ethylene Oxide Sensor Assembly |
| 967-272790-001 | DM-700-F2 Fluorine Sensor Assembly |
| 967-12EP90-100 | DM-700-CH2O Formaldehyde Sensor Assembly |
| 967-848490-100 | DM-700-H2 Hydrogen Sensor Assembly (ppm range) |
| 967-070790-01P | DM-702-H2 Hydrogen Sensor Assembly (1% range) |
| 967-050590-04P | DM-702-H2 Hydrogen Sensor Assembly (4% range) |
| 967-090890-030 | DM-700-HBr Hydrogen Bromide Sensor Assembly |
| 967-090990-030 | DM-700-HCl Hydrogen Chloride Sensor Assembly |
| 967-131390-030 | DM-700-HCN Hydrogen Cyanide Sensor Assembly |
| 967-333390-010 | DM-700-HF Hydrogen Fluoride Sensor Assembly |
| 967-12EE90-100 | DM-700-CH3OH Methanol Sensor Assembly |
| 967-24EK90-100 | DM-700-CH3SH Methyl Mercaptans Sensor Assembly |
| 967-949490-100 | DM-700-NO Nitric Oxide Sensor Assembly |
| 967-646490-010 | DM-700-NO2 Nitrogen Dioxide Sensor Assembly |
| 967-393990-001 | DM-700-O3 Ozone Sensor Assembly |
| 967-192090-005 | DM-700-PH3 Phosphine Sensor Assembly |
| 967-555590-020 | DM-700-SO2 Sulfur Dioxide Sensor Assembly |
| Gas | Part Number | Measuring Range | Warranty |
|---|---|---|---|
| Acetylene* | 967-12EG91-100 | 0-100 ppm | 2 Years |
| Ammonia | 967-505091-100 | 0-100 ppm | 2 Years |
| Arsine | 967-191991-001 | 0-1 ppm | 1.5 Years |
| Bromine | 967-747591-005 | 0-5 ppm | 2 Years |
| Butadiene | 967-12EB91-100 | 0-100 ppm | 2 Years |
| Carbon Monoxide | 967-444491-100 | 0-100 ppm | 3 Years |
| Chlorine | 967-747491-010 | 0-10 ppm | 2 Years |
| Chlorine Dioxide 700 | 967-747691-050 | 0-50 ppm | 2 Years |
| Chlorine Dioxide 701 | 967-777791-001 | 0-1 ppm | 2 Years |
| Diborane | 967-192191-005 | 0-5 ppm | 1.5 Years |
| Ethanol | 967-12EO91-100 | 0-100 ppm | 2 Years |
| Ethylene** | 967-12ED91-100 | 0-100 ppm | 2 Years |
| Ethylene Oxide | 967-12EJ91-100 | 0-100 ppm | 2 Years |
| Fluorine | 967-272791-001 | 0-1 ppm | 1.5 Years |
| Formaldehyde | 967-12EP91-100 | 0-100 ppm | 2 Years |
| Germane | 967-232591-002 | 0-2 ppm | 1.5 Years |
| Hydrogen (1%) | 967-070791-01P | 0-1% Volume | 2 Years |
| Hydrogen (4%) | 967-050591-04P | 0-4% Volume | 2 Years |
| Hydrogen PPM | 967-848491-100 | 0-100 ppm | 2 Years |
| Hydrogen Bromide | 967-090891-030 | 0-30 ppm | 1.5 Years |
| Hydrogen Chloride | 967-090991-030 | 0-30 ppm | 1.5 Years |
| Hydrogen Cyanide | 967-131391-030 | 0-30 ppm | 2 Years |
| Hydrogen Fluoride | 967-333391-010 | 0-10 ppm | 1.5 Years |
| Methanol | 967-12EE91-100 | 0-100 ppm | 2 Years |
| Methyl Mercaptan | 967-12EK91-100 | 0-100 ppm | 2 Years |
| Nitric Oxide | 967-949491-100 | 0-100 ppm | 3 Years |
| Nitrogen Dioxide | 967-646491-010 | 0-10 ppm | 2 Years |
| Oxygen | 967-341520-025 | 0-25% Volume | 2 Years |
| Ozone | 967-393991-001 | 0-1 ppm | 2 Years |
| Phosphine | 967-192091-005 | 0-5 ppm | 1.5 Years |
| Silane | 967-232391-050 | 0-50 ppm | 1.5 Years |
| Sulfur Dioxide | 967-555591-020 | 0-20 ppm | 2 Years |
| System Specifications | |
|---|---|
| Sensor Type | Continuous diffusion/adsorption, 3-electrode electrochemical cell, plug-in field replaceable Intelligent Type |
| Outputs | Linear 4-20 mA DC, RS-485 MODBUS-RTU |
| Electrical Classification |
Explosion Proof cCSAus Class I, Division 1, Groups B, C, D Class I, Zone 1, Group IIC ATEX: II 2 G Ex d ib IIB + H2 T4 Gb |
| Ingress Protection | NEMA 4X, IP66 |
| Safety Approvals | cCSAus, ATEX, CE Marking, SIL2 Certified to IEC 61508 |
| Mechanical Specifications | |
| Dimensions |
Sensor Assembly: 7”H × 2.2” Dia. (178 mmH × 65 mm Dia.) With Junction Box: 11”H × 6.1”W × 3.75”D (280 mmH × 155 mmW × 96 mmD) Mounting Holes: 5.5” (140 mm) centre-to-centre |
| Weight |
2 lbs (0.907 kg) – Sensor Only 6 lbs (2.72 kg) – With Aluminum Junction Box 9 lbs (4.08 kg) – With Stainless Steel Junction Box |
| Electrical Specifications | |
| Power Input | 11 – 30 VDC |
| Power Consumption |
Normal Operation = 30 mA @ 24V (<0.75 W) Maximum = 50 mA @ 24V (1.2 W) |
| Inrush Current | 500 mA @ 24V (Typical) |
| RFI/EMI Protection | Complies with EN50270 |
| Analog Output |
Linear 4-20mA DC (1,000 Ω max loop load @ 24VDC) 0mA – All Fault Diagnostics 2mA – In Calibration 4-20mA – 0-100% Full Scale 22mA – Over-range Condition |
| Serial RS-485 Output | RS-485 Modbus™ RTU |
| Baud Rate | 9600 BPS (9600, N, 8, 1 Half Duplex) |
| Status Indicators | 4-digit LED Display with Gas Concentration, AutoSpan, Set-up Options and Fault Reporting Menus |
| Faults Monitored | Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration |
| Cable Requirements |
Power/Analog: 3-wire shielded cable, maximum distance 13,300 ft with 14 AWG Serial Output: 2-wire twisted-pair with ground, shielded communication cable for RS-485 installations, maximum distance 4,000 ft to last sensor |
| I/O Protection | Over-voltage, Miswiring, EMI/RFI Immunity |
Note: Acetylene can only be used with a Group A enclosure.
Note 2: Ethylene detectors are safety devices intended to detect hazardous conditions and are not designed for process control applications in fruit ripening operations.
Get in touch with us to see how we can help you with your project