The Detcon DM-700-O2 by Teledyne is a non-intrusive “Smart” sensor designed to detect and monitor Oxygen in the air over the range of 0-25% by volume using electrochemical sensor technology. The plug-in, field-replaceable sensor cell is temperature compensated and features oversized gold-plated connections that help prevent corrosion.
The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual-layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes.
A primary feature of the Model 700 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analogue 4-20mA and Modbus RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s Smart Wireless product line.
Additional integration options include a Remote Alarm Module (RAM) and HART. Detcon’s oxygen sensors have a long shelf life and are supported by an industry-leading warranty.
Applications: Petrochemical, Refineries, Chemical plants, Confined Space Monitoring, Analyser Shelters, Wastewater treatment plants, Wet wells-dry wells, Pulp and paper, Food and beverage and Utilities.
| Part Number | Description |
|---|---|
| 967-343490-25P | DM-700-O2 Oxygen Deficiency Sensor Assembly (no condulet) |
| 967-343491-25P | DM-700-O2 Oxygen Deficiency Gas Sensor Assembly (aluminium condulet) |
| 967-343494-25P | DM-700-O2 Oxygen Deficiency Gas Sensor Assembly (316SS condulet) |
| 9H7-343491-25P | DM-700-O2 Oxygen Deficiency Gas Sensor with HART bridge Assembly (aluminium condulet) |
| 9H7-343494-25P | DM-700-O2 Oxygen Deficiency Gas Sensor with HART bridge Assembly (316SS condulet) |
| 9R7-343491-25P | DM-700-O2 Oxygen Deficiency Gas Sensor with RAM Assembly (aluminium condulet) |
| 9R7-343494-25P | DM-700-O2 Oxygen Deficiency Gas Sensor with RAM Assembly (316SS condulet) |
| 9K7-343491-25P | DM-700-O2 Oxygen Deficiency Gas Sensor with HART-RAM Assembly (aluminium condulet) |
| 9K7-343494-25P | DM-700-O2 Oxygen Deficiency Gas Sensor with HART-RAM Assembly (316SS condulet) |
| Part Number | Description |
|---|---|
| 377-343401-025 | O2 Oxygen plug-in sensor for DM-700 |
| S927-343400-25P | DM-700-O2 Oxygen Deficiency (ITM) |
| 602-003803-000 | CXT / 700 DM Splashguard Adapter (Stainless Steel) |
| System Specifications | |
|---|---|
| Sensor Type | Continuous diffusion/adsorption, 2-electrode electrochemical cell, plug-in field replaceable intelligent type |
| Sensor Life | 2.5 to 3 years typical |
| Measurement Range | 0-25% Oxygen by Volume |
| Accuracy / Repeatability | ±1% FS |
| Response / Clearing Time | T90 ≤ 10 seconds |
| Span Drift | <5% of signal per year (in first two years) |
| Outputs | Linear 4-20 mA DC, RS-485 Modbus RTU |
| Electrical Classification |
Explosion Proof CSA and US (NRTL) Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C) Class I, Zone 1, Group IIC ATEX: II 2 G Ex d ib IIB + H2 T4 Gb (Tamb = -40°C to +50°C) |
| Ingress Protection | NEMA 4X, IP66 |
| Safety Approvals | cCSAus, ATEX, CE Marking, SIL2 Certified to IEC 61508 |
| Warranty | Plug-in Cell – 2 Years; Transmitter – 2 Years |
| Environmental Specifications | |
| Operating Temperature Range | -40°F to +122°F (-40°C to +50°C) |
| Storage Temperature Range | -40°F to +122°F (-40°C to +50°C) |
| Operating Humidity Range | 0-99% RH Non-Condensing |
| Operating Pressure Range | Atmospheric ±10% |
| Mechanical Specifications | |
| Dimensions |
Sensor Assembly: 7" H × 2.2" Dia. (178 mm H × 65 mm Dia.) With Junction Box: 11" H × 6.1" W × 3.75" D (280 mm H × 155 mm W × 96 mm D) Mounting Holes (J-Box): 5.5" (140 mm) center-to-center |
| Weight |
2 lbs (0.907 kg) – Sensor Only 6 lbs (2.72 kg) – With Aluminum Junction Box 9 lbs (4.08 kg) – With Stainless Steel Junction Box |
| Electrical Specifications | |
| Power Input | 11-30 VDC |
| Power Consumption |
Normal Operation: 30 mA (<0.75 W) Maximum: 50 mA (1.2 W) |
| Inrush Current | 1.67 A @ 24 VDC |
| RFI / EMI Protection | Complies with EN50270 |
| Analog Output |
Linear 4-20 mA DC (1,000 Ω max loop load @ 24 VDC) 0 mA – All Fault Diagnostics 2 mA – In Calibration 4-20 mA – 0-100% Full Scale 22 mA – Over-Range Condition |
| Serial RS-485 Output | RS-485 Modbus™ RTU |
| Baud Rate | 9600 BPS (9600, N, 8, 1 Half Duplex) |
| Status Indicators | 4-digit LED Display with Gas Concentration, Full-Script Menu Prompts for AutoSpan, Set-up Options and Fault Reporting |
| Faults Monitored | Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration |
| Cable Requirements |
Power/Analog: 3-wire shielded cable, maximum distance 13,300 ft with 14 AWG Serial Output: 2-wire twisted-pair shielded cable for RS-485 installations, maximum distance 4,000 ft to last sensor |
| I/O Protection | Over-voltage, Miswiring, EMI/RFI Immunity |
Get in touch with us to see how we can help you with your project