The Detcon DM-100 series sensor features intelligent electronics, a non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread.
The plug-in, field-replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are entirely encapsulated in the sensor housing, adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.
Model DM-100 sensors provide a 2-wire loop-powered 4-20 mA current signal equivalent to the sensor detection range. Upper enclosure options are aluminium and stainless steel.
Additional accessories include wireless communications and a loop-powered digital display. Each sensor is shipped with a splash guard with an integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
| Part Number | Description |
|---|---|
| 961-190026-001 | AsH3, Arsine Sensor Assembly DM-100 |
| 961-210026-005 | B2H6, Diborane Sensor Assembly DM-100 |
| 961-750026-005 | Br2, Bromine Sensor Assembly DM-100 |
| 961-ED0026-100 | C2H4, Ethylene Sensor Assembly DM-100 |
| 961-EJ0026-100 | C2H4O, Ethylene Oxide Sensor Assembly DM-100 |
| 961-EO0026-100 | C2H5OH, Ethanol Sensor Assembly DM-100 |
| 961-EZ0026-100 | C2H5SH, Ethyl Mercaptans Sensor Assembly DM-100 |
| 961-EB0026-100 | C4H6, Butadiene Sensor Assembly DM-100 |
| 961-EP0026-100 | CH2O, Formaldehyde Sensor Assembly DM-100 |
| 961-EE0026-100 | CH3OH, Methanol Sensor Assembly DM-100 |
| 961-EK0026-100 | CH3SH, Methyl Mercaptans Sensor Assembly DM-100 |
| 961-740026-010 | Cl2, Chlorine Sensor Assembly DM-100 |
| 961-770026-001 | ClO2, Chlorine Dioxide (0–1 ppm) Sensor Assembly DM-100 |
| 961-760026-050 | ClO2, Chlorine Dioxide (0–50 ppm) Sensor Assembly DM-100 |
| 961-440026-100 | CO, Carbon Monoxide Sensor Assembly DM-100 |
| 961-270026-001 | F2, Fluorine Sensor Assembly DM-100 |
| 961-840026-100 | H2, Hydrogen (ppm range) Sensor Assembly DM-100 |
| 961-240026-100 | H2S, Hydrogen Sulfide Sensor Assembly DM-100 |
| 961-070026-01P | H2 Hydrogen (0–1% Vol.) Sensor Assembly DM-100 |
| 961-080026-030 | HBr, Hydrogen Bromide Sensor Assembly DM-100 |
| 961-090026-030 | HCl, Hydrogen Chloride Sensor Assembly DM-100 |
| 961-130026-030 | HCN, Hydrogen Cyanide Sensor Assembly DM-100 |
| 961-330026-010 | HF, Hydrogen Fluoride Sensor Assembly DM-100 |
| 961-500026-100 | NH3, Ammonia Sensor Assembly DM-100 |
| 961-940026-100 | NO, Nitric Oxide Sensor Assembly DM-100 |
| 961-640026-010 | NO2, Nitrogen Dioxide Sensor Assembly DM-100 |
| 961-340026-025 | O2, Oxygen Deficiency Sensor Assembly DM-100 |
| 961-390026-001 | O3, Ozone Sensor Assembly DM-100 |
| 961-200026-005 | PH3, Phosphine Sensor Assembly DM-100 |
| 961-550026-020 | SO2, Sulfur Dioxide Sensor Assembly DM-100 |
| System Specifications | |
|---|---|
| Sensor Type | Continuous diffusion/adsorption 2-electrode electrochemical cell Plug-in field replaceable type |
| Span Drift | <5% signal loss per year (first 2 years) |
| Outputs | Linear 4-20 mA DC |
| Electrical Classification | Explosion Proof cCSAus Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C) |
| Safety Approvals | cCSAus |
| Environmental Specifications | |
| Operating Humidity Range | 0% to 99% RH non-condensing (continuous) 0% to 100% RH (intermittent) |
| Operating Pressure Range | Atmospheric ±10% |
| Mechanical Specifications | |
| Dimensions |
7" H × 2.2" Dia. (178 mm H × 65 mm Dia.) – Sensor Assembly Only 11" H × 6.1" W × 3.75" D (280 mm H × 155 mm W × 96 mm D) – With Junction Box Mounting Holes (J-Box): 5.5" (140 mm center-to-center) |
| Weight |
2 lbs (0.907 kg) – Sensor Only 6 lbs (2.72 kg) – With Aluminum Junction Box 9 lbs (4.08 kg) – With Stainless Steel Junction Box |
| Electrical Specifications | |
| Power Input | 11 – 30 VDC |
| Power Consumption |
Normal Operation = 30 mA @ 24 V (<0.75 W) Maximum = 50 mA @ 24 V (1.2 W) |
| Inrush Current | 500 mA @ 24 V (Typical) |
| Analog Output |
Linear 4-20 mA DC (1,000 Ω max loop load @ 24 VDC) 0 mA – All Fault Diagnostics 2 mA – In Calibration 4-20 mA – 0-100% Full Scale 22 mA – Over-range Condition |
| Status Indicators |
Optional 4-digit LED display with gas concentration Full-script menu prompts for AutoSpan, Setup Options, and Fault Reporting |
| Faults Monitored | Loop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration |
| Cable Requirements |
Power/Analog: 3-wire shielded cable Maximum distance: 13,300 ft with 14 AWG cable |
| Serial Output |
2-wire twisted-pair with ground, shielded communication cable for RS-485 installations Maximum distance: 4,000 ft to last sensor |
| I/O Protection | Over-voltage, Miswiring |
Get in touch with us to see how we can help you with your project