Crowcon Xgard Type 6 Fixed Gas Detector

  1. Home
  2. Products

Crowcon Xgard Type 6 Fixed Gas Detector

The Xgard Type 6 is an Exd Flameproof gas detector using a thermal conductivity sensor within an Xgard enclosure, which also contains an amplifier to provide a 3-wire 4-20mA sink or source output. Operating temperature +10 to +55°C. Designed to detect % vol. levels of gas in binary mixtures.

Suitable for use with a range of cable glands: M20 or 1/2″ NPT or 3/4″ NPT. There is a choice of housing: durable aluminium with a tough polyester coating, or 316 stainless steel suitable for deployment in extreme environments, such as offshore or in heavy industry, corrosion-resistant.

Units can be installed on walls or ceilings, with three junction box choices—replacement sensors plugin. Accessories are available for duct mounting, sampling applications and remote gassing – simple sensor checking. In wash-down areas or marine applications, splash guards and weatherproof caps are available.

Features

  • For Hydrogen (H2) 0-5%, 10%, 50% vv (in air) 0-20%, 25%, 30%, 50% vv (H2 in N2).
  • Argon (Ar) or Carbon dioxide (CO2) detection, please enquire.
  • Simple install and maintenance, common spares for all Xgard types, minimise inventory.
  • Validated to IEC 61508 (SIL 1 to SIL 3).
  • Ingress protection IP65.
  • Response time T90 <15s (typical).
  • Global approvals ATEX/ IECEx UL, INMETRO & GOST-R.
  • Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches).
  • Weight Aluminium 1kg. Stainless steel: 3.1kg.

Xgard Type 6 Hydrogen Detectors

Part Number Description
XG6-A2-02-TR Xgard Type 6 Aluminium, 1/2" NPT, UL certified, Hydrogen (H₂) 0-5% vol in air
XG6-A4-02-FT Xgard Type 6 Aluminium, 3/4" NPT, UL certified, Hydrogen (H₂) 0-20% vol in Nitrogen
XG6-A1-01-FV Xgard Type 6 Aluminium, M20, ATEX/IECEx certified, Hydrogen (H₂) 0-10% vol in air
XG6-A1-01-FT Xgard Type 6 Aluminium, M20, ATEX/IECEx certified, Hydrogen (H₂) 0-20% vol in Nitrogen
XG6-A1-01-TT Xgard Type 6 Aluminium, M20, ATEX/IECEx certified, Hydrogen (H₂) 0-50% vol in air
XG6-A1-01-FU Xgard Type 6 Aluminium, M20, ATEX/IECEx certified, Hydrogen (H₂) 0-50% vol in Nitrogen
XG6-A1-01-TR Xgard Type 6 Aluminium, M20, ATEX/IECEx certified, Hydrogen (H₂) 0-5% vol in air
XG6-S5-07-FU Xgard Type 6 Stainless Steel, 2 × M20, INMETRO certified, Hydrogen (H₂) 0-50% vol in Nitrogen

Xgard Type 6 Spare Sensor Modules

Part Number Measuring Range
S011540/S 0-5% vol Hydrogen (in air)
S011548/S 0-20% vol Hydrogen (in Nitrogen)
S011947/S 0-50% vol Hydrogen (in Nitrogen)

Xgard Accessories

Part Number Description
C011061 Accessory adaptor (spare) – M20 threaded adaptor for connecting accessories
C01051 Collector cone – Includes accessory adaptor. Aids detection of light gases such as methane
C01052 Spray deflector – Includes accessory adaptor. Protects from water sprays in outdoor installations
C01442 Weatherproof cap – Includes accessory adaptor. Suitable for offshore or wet environments
C01339 Flow adaptor for sampling applications
C011063 Sun shield – Protects against heat build-up from direct sunlight. Supplied with fixing rivets
C03005 Calibration adaptor
C01254 Carbon cloth filter (self-adhesive) – For Xgard Types 3, 4 & 5 only. Removes long-chain hydrocarbons
S011918 Duct mounting kit – Stainless steel plate with 6 mm remote calibration fitting. Maximum airflow 6 m/s. Not compatible with Stainless Steel Xgard
2575/2 Detector pulley system for lowering methane and hydrogen detectors from high locations for calibration
00109A Calibration termination box (ABS enclosure) for remote gas application
M04214 PTFE tube, 6 mm OD × 1 mm wall, for use with calibration termination box (priced per metre)

Enquire About This Product