Crowcon Xgard Type 3 Fixed Gas Detector

  1. Home
  2. Products

Crowcon Xgard Type 3 Fixed Gas Detector

The Crowcon Xgard Type 3 is an Exd Flameproof flammable gas detector using a poison-resistant pellistor within an Xgard enclosure, which also contains the terminals to provide a three-wire mV Wheatstone Bridge output. Can be connected directly to Crowcon Gasmaster and Gasmonitor. An Accessory Enclosure is required for connection to 4-20mA type control systems such as Vortex.

Suitable for use with a range of cable glands: M20 or 1/2″ NPT or 3/4″ NPT. There is a choice of housing: durable aluminium with a tough polyester coating or 316 stainless steel, suitable for deployment in extreme environments, such as offshore or in heavy industry, corrosion-resistant.

Units can be installed on walls or ceilings, with three junction box choices—replacement sensors plugin. Accessories are available for duct mounting, sampling applications and remote gassing – simple sensor checking. In wash-down areas or marine applications, splash guards and weatherproof caps are available.

Features

  • Simple install and maintenance, common spares for all Xgard types, minimise inventory.
  • Validated to IEC 61508 (SIL 1 to SIL 3).
  • Ingress protection IP65.
  • Operating temperature -40 to +80°C.
  • Response time T90 <15s (typical).
  • Global approvals ATEX/ IECEx UL, INMETRO & GOST-R.
  • Size 156 x 166 x 111 mm (6.1 x 6.5 x 4.3 inches).
  • Weight: Aluminium 1kg & Stainless Steel 3.1kg.

Xgard Type 3 Detectors

Part Number Description
XG3-A2-01-FDXgard Type 3 Aluminium, 1/2" NPT, ATEX/IECEx, Methane (CH₄), 0-100% LEL
XG3-A2-01-FQXgard Type 3 Aluminium, 1/2" NPT, ATEX/IECEx, Ammonia (NH₃), 0-25% LEL
XG3-A2-02-FHXgard Type 3 Aluminium, 1/2" NPT, UL, Propane (C₃H₈), 0-100% LEL
XG3-A2-02-FGXgard Type 3 Aluminium, 1/2" NPT, UL, Butane (C₄H₁₀), 0-100% LEL
XG3-A2-02-FDXgard Type 3 Aluminium, 1/2" NPT, UL, Methane (CH₄), 0-100% LEL
XG3-A1-01-FMXgard Type 3 Aluminium, M20, ATEX/IECEx, Acetylene (C₂H₂), 0-100% LEL
XG3-A1-01-FCXgard Type 3 Aluminium, M20, ATEX/IECEx, Ethylene (C₂H₄), 0-100% LEL
XG3-A1-01-FBXgard Type 3 Aluminium, M20, ATEX/IECEx, Ethanol (C₂H₅OH), 0-100% LEL
XG3-A1-01-FHXgard Type 3 Aluminium, M20, ATEX/IECEx, Propane (C₃H₈), 0-100% LEL
XG3-A1-01-FGXgard Type 3 Aluminium, M20, ATEX/IECEx, Butane (C₄H₁₀), 0-100% LEL
XG3-A1-01-FIXgard Type 3 Aluminium, M20, ATEX/IECEx, Pentane (C₅H₁₂), 0-100% LEL
XG3-A1-01-FYXgard Type 3 Aluminium, M20, ATEX/IECEx, Hexane (C₆H₁₄), 0-100% LEL
XG3-A1-01-FJXgard Type 3 Aluminium, M20, ATEX/IECEx, Toluene (C₇H₈), 0-100% LEL
XG3-A1-01-FLXgard Type 3 Aluminium, M20, ATEX/IECEx, Methanol (CH₃OH), 0-100% LEL
XG3-A1-01-FDXgard Type 3 Aluminium, M20, ATEX/IECEx, Methane (CH₄), 0-100% LEL
XG3-A1-01-FAXgard Type 3 Aluminium, M20, ATEX/IECEx, Hydrogen (H₂), 0-100% LEL
XG3-A1-01-FRXgard Type 3 Aluminium, M20, ATEX/IECEx, Jet Fuel, 0-100% LEL
XG3-A1-01-FWXgard Type 3 Aluminium, M20, ATEX/IECEx, LPG, 0-100% LEL
XG3-A1-01-FQXgard Type 3 Aluminium, M20, ATEX/IECEx, Ammonia (NH₃), 0-25% LEL
XG3-A1-01-FFXgard Type 3 Aluminium, M20, ATEX/IECEx, Petrol Vapour (Unleaded), 0-100% LEL
XG3-A1-02-FAXgard Type 3 Aluminium, M20, UL, Hydrogen (H₂), 0-100% LEL
XG3-S2-01-FQXgard Type 3 Stainless Steel, 1/2" NPT, ATEX/IECEx, Ammonia (NH₃), 0-25% LEL
XG3-S5-01-FAXgard Type 3 Stainless Steel, 2 × M20, ATEX/IECEx, Hydrogen (H₂), 0-100% LEL
XG3-S1-01-FIXgard Type 3 Stainless Steel, M20, ATEX/IECEx, Pentane (C₅H₁₂), 0-100% LEL
XG3-S1-01-FDXgard Type 3 Stainless Steel, M20, ATEX/IECEx, Methane (CH₄), 0-100% LEL
XG3-S1-01-FWXgard Type 3 Stainless Steel, M20, ATEX/IECEx, LPG, 0-100% LEL
XG3-S1-01-FFXgard Type 3 Stainless Steel, M20, ATEX/IECEx, Petrol Vapour (Unleaded), 0-100% LEL

Xgard Type 3 Spare Sensor Modules

Part Number Description
S011509/S0-100% LEL Methane Sensor Module – Pellistor VQ21T
S011511/S0-100% LEL Pentane Sensor Module – Pellistor VQ21T
S011513/S0-100% LEL Hydrogen Sensor Module – Pellistor VQ21T
S011517/S0-100% LEL Ethanol Sensor Module – Pellistor VQ21T
S012162/S0-100% LEL Methanol Sensor Module – Pellistor VQ21T
S011518/S0-100% LEL Acetylene Sensor Module – Pellistor VQ21T
S011519/S0-100% LEL Butane Sensor Module – Pellistor VQ21T
S011520/S0-100% LEL Ethane Sensor Module – Pellistor VQ21T
S011521/S0-100% LEL Ethylene Sensor Module – Pellistor VQ21T
S011522/S0-100% LEL LPG Sensor Module – Pellistor VQ21T
S011523/S0-100% LEL Propane Sensor Module – Pellistor VQ21T
S011524/S0-100% LEL Petrol Vapour (Unleaded) Sensor Module – Pellistor VQ21T
S012171/S0-25% LEL Hydrogen Sensor Module – Pellistor VQ21T
S012003/S0-100% LEL Acetaldehyde Sensor Module – Pellistor 300P
S012973/S0-100% LEL Hexane Sensor Module – Pellistor VQ21T
S012977/S0-100% LEL Isopropyl Alcohol (IPA) Sensor Module – Pellistor VQ21T
S0111001/S0-100% LEL Toluene Sensor Module – Pellistor VQ21T
S011840/S0-100% LEL Ethylene Dichloride (EDC) Sensor Module – Pellistor VQ25
S012972/S0-100% LEL Vinyl Chloride Monomer (VCM) Sensor Module – Pellistor VQ25
S011487/S0-100% LEL Jet Fuel Sensor Module – Pellistor VQ41T
S011489/S0-25% LEL Ammonia Sensor Module – Pellistor VQ41T
S012988/S0-100% LEL Methane Sensor Module – Pellistor NP-30#
S012989/S0-100% LEL Pentane Sensor Module – Pellistor NP-30#

Enquire About This Product

Get in touch with us to see how we can help you with your project

Thank you Message Sent