Designed to meet the toughest industrial standards, the SMART S-SS series gas detectors are used to detect, in classified areas (zone 1 and, if equipped with the dust adapter, zone 21), the presence of flammable substances (% LFL).
The catalytic sensor detects flammable substances, combining excellent linearity up to 100% LFL with fast response times. The sensor is housed in a stainless steel head, with a diameter of 47.5 mm.
The detector has a 12-24 Vdc power supply, a 4-20 mA signal output and an RS485 signal.
The SMART S-SS is equipped with a display (LCD or LED) to monitor the concentration in real-time and Hall effect sensors for non-intrusive calibration in the field.
The SMART S-SS detector has the following customisation possibilities:
| Part Number | Description |
|---|---|
| SSS3A11 | Electronic with output RS485 + 4-20 mA, LCD display |
| SSS3A12 | Electronic with output RS485 + 4-20 mA, LED display |
| SSS3A13 | Electronic with output RS485 + 4-20 mA, LCD display, relay card |
| SSS3A14 | Electronic with output RS485 + 4-20 mA, LED display, relay card |
| SSS3A17 | Electronic with output RS485 + 4-20 mA, LCD display, relay card, Modem Hart |
| SSS3A18 | Electronic with output RS485 + 4-20 mA, LED display, relay card, Modem Hart |
| Part Number | Description |
|---|---|
| SSS4A11 | Electronic with output RS485 + 4-20 mA, LCD display |
| SSS4A12 | Electronic with output RS485 + 4-20 mA, LED display |
| SSS4A13 | Electronic with output RS485 + 4-20 mA, LCD display, 3-relay card |
| SSS4A14 | Electronic with output RS485 + 4-20 mA, LED display, 3-relay card |
| SSS4A17 | Electronic with output RS485 + 4-20 mA, LCD display, 3-relay card, Modem Hart |
| SSS4A18 | Electronic with output RS485 + 4-20 mA, LED display, 3-relay card, Modem Hart |
| Part Number | Description |
|---|---|
| SSS2S11 | Electronic with output RS485 + 4-20 mA, LCD display |
| SSS2S12 | Electronic with output RS485 + 4-20 mA, LED display |
| SSS2S13 | Electronic with output RS485 + 4-20 mA, LCD display, 3-relay card |
| SSS2S14 | Electronic with output RS485 + 4-20 mA, LED display, 3-relay card |
| SSS2S17 | Electronic with output RS485 + 4-20 mA, LCD display, 3-relay card, Modem Hart |
| SSS2S18 | Electronic with output RS485 + 4-20 mA, LED display, 3-relay card, Modem Hart |
| Sensor Part Number | Description |
|---|---|
| S4003ME | METHANE sensor head, 0-100% LFL |
| S4003GP | LPG sensor head, 0-100% LFL |
| S4003PR | PROPANE sensor head, 0-100% LFL |
| S4003BU | BUTANE sensor head, 0-100% LFL |
| S4003VB | PETROL VAPOURS sensor head, 0-100% LFL |
| S4003AT | ACETONE sensor head, 0-100% LFL |
| S4037AC | ACETYLENE sensor head, 0-100% LFL |
| S4003AM | AMMONIA sensor head, 0-100% LFL |
| S4003CP | CYCLOPENTANE sensor head, 0-100% LFL |
| S4003EN | ETHANE sensor head, 0-100% LFL |
| S4003AE | ETHYL ACETATE sensor head, 0-100% LFL |
| S4003ET | ETHYL ALCOHOL sensor head, 0-100% LFL |
| S4003EL | ETHYLENE sensor head, 0-100% LFL |
| S4003EP | HEPTANE sensor head, 0-100% LFL |
| S4003ES | HEXANE sensor head, 0-100% LFL |
| S4003H2 | HYDROGEN sensor head, 0-100% LFL |
| S4003IB | ISO BUTANE sensor head, 0-100% LFL |
| S4002P8 | JP8 sensor head, 0-100% LFL |
| S4003MT | METHYL ALCOHOL sensor head, 0-100% LFL |
| S4003MK | METHYL ETHYL KETONE (MEK) sensor head, 0-100% LFL |
| S4003PE | PENTANE sensor head, 0-100% LFL |
| S4003PP | PROPYLENE sensor head, 0-100% LFL |
| S4003PN | PROPYL ALCOHOL sensor head, 0-100% LFL |
| S4003ST | STYRENE sensor head, 0-100% LFL |
| S4003TO | TOLUENE sensor head, 0-100% LFL |
| S4003XI | XYLENE sensor head, 0-100% LFL |
| STS/CKD+ | Enhanced calibration keypad with 7-digit display and SD-CARD slot for Zero, Span, 4-20 mA adjustment and firmware update |
| STS/CKD-OLED | Advanced calibration keypad with OLED display, graphical visualization, SD card logging and firmware update capability |
| Sensor | |
| Application | Industrial areas, ATEX Zone 1 and Zone 21 (if equipped with optional dust adapter) |
| Sensor | Catalytic pellistor |
| Estimated sensor life | 4 / 5 years |
| Gas detected | Flammable |
| Full scale | 0 – 100% LFL |
| Electrical parameters | |
| Power supply | 12-24 Vdc |
| Output | Analogue 4-20 mA output; RS485 serial output; 3 relay board (optional); HART modem (optional) |
| Maximum dissipated power | 5.4 W |
| Relays contact ratings | 1.0 A a 24 Vdc |
| Visual indications | LED or LCD display |
| Acoustic indications | – |
| Hall effect sensor | Three sensors for calibration by magnet |
| Environmental conditions | |
| Storage temperature | -40 / +85°C |
| Operating temperature |
-20 / +60°C * (LCD) -40 / +65°C * (LED) |
| Operating humidity | 20 / 90% RH @40°C * |
| Operating pressure | 80 / 120 kPa * |
| Air velocity | 6 m/s * |
| Response time | t90 < 60 s ; t50 < 20 s * |
| * Data tested according to test procedures described in EN 60079-29-1 standard | |
| External case | |
| Material |
Enclosure: die-cast aluminium with colour and chemically resistant epoxy paint
or electropolished SS316 stainless steel Sensor head: SS316 stainless steel |
| Protection mode |
Ex d : Explosion proof enclosure Ex t : Equipment dust ignition protection by enclosure (when equipped with optional dust adapter) |
| Dimensions |
145 x 187 x 110 mm (3A enclosure) 138 x 200 x 120 mm (4A enclosure) 155 x 210 x 124 mm (2S enclosure) |
| Weight |
1700 g (3A enclosure) 2800 g (4A enclosure) 4200 g (2S enclosure) |
| Cable entries | 2 or 3 x 3/4” NPT |
| IP grade | IP65 |
| Compliance | |
| EMC | EN 61000-6-3:2007 + A1:2011; EN 50270:2015 |
| ATEX |
Direttiva ATEX 2014/34/UE EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-31:2014 EN 60079-29-1:2016 |
| IECEx |
IEC 60079-0:2011 IEC 60079-1:2014 IEC 60079-31:2013 |
| SIL |
EN 61508:2010 Parti 1, 2, 3, 4, 5, 6, 7 EN 50402:2017 |