Crowcon Sensitron SMART 3G-C2-LD Infrared Gas Detector

  1. Home
  2. Products

Crowcon Sensitron SMART 3G-C2-LD Infrared Gas Detector

The SMART3G-C2-LD is equipped with an infrared sensor and is designed to meet industrial requirements. The enclosure is explosion-proof and can be installed in ATEX Zone 1. It can be used in Zone 21 when fitted with a dust adapter.

The sensing element is placed in the stainless steel head with a 48 mm diameter.

The infrared sensors employed for flammable and refrigerant gas detection are poison-free, with high accuracy and a long lifetime.

The gas detector has a 12-24 Vdc power supply, a standard 4-20 mA 3-wires output, and three relays. Optionally, the SMART3G-C2-LD can be equipped with serial RS485 communication.

The aluminium enclosure has dimensions 145 x 187 x 108 mm. The enclosure has three cable entries that are 3/4” NPT threaded. The multi-colour LED light ring assures an immediate visual indication of the detector status.

The SMART3G-C2-LD is SIL2 hardware and SIL3 software with a redundant system; the hardware is SIL3.

SMART3G-C2-LD – Flammable Gas (Infrared Sensor)

Part Number Gas Type Output & Range
S2624ME-LD Methane 4-20 mA, 0-100% LFL
S2654BU-LD Butane 4-20 mA, 0-100% LFL
S2654PR-LD Propane 4-20 mA, 0-100% LFL
S2654GP-LD LPG 4-20 mA, 0-100% LFL
S2654AT-LD Acetone 4-20 mA, 0-100% LFL
S2654BN-LD Butadiene 4-20 mA, 0-100% LFL
S2654CE-LD Cyclo Hexane 4-20 mA, 0-100% LFL
S2654DT-LD Dimethyl Ether 4-20 mA, 0-100% LFL
S2654EN-LD Ethane 4-20 mA, 0-100% LFL
S2654AE-LD Ethyl Acetate 4-20 mA, 0-100% LFL
S2654ET-LD Ethyl Alcohol 4-20 mA, 0-100% LFL
S2654EP-LD Heptane 4-20 mA, 0-100% LFL
S2654ES-LD Hexane 4-20 mA, 0-100% LFL
S2654IB-LD Iso Butane 4-20 mA, 0-100% LFL
S2654IL-LD Isobutylene 4-20 mA, 0-100% LFL
S2654IP-LD Iso Propyl Alcohol 4-20 mA, 0-100% LFL
S2654PE-LD Pentane 4-20 mA, 0-100% LFL
S2654PP-LD Propylene 4-20 mA, 0-100% LFL
S2654DE-LD R152a 4-20 mA, 0-100% LFL
S4433R454B-LD R454B 4-20 mA, 0-100% LFL
S4827R454C-LD R454C 4-20 mA, 0-100% LFL
S3425R32-LD R32 4-20 mA, 0-100% LFL
S3429R1234YF-LD R1234yf 4-20 mA, 0-100% LFL
S3433R1234ZE-LD R1234ze 4-20 mA, 0-100% LFL

SMART3G-C2-LD – CO₂ (Infrared Sensor)

Part Number Gas Type Range
S3898CO2-LD CO₂ 0-5000 ppm
S2651CO2-LD CO₂ 0-2% Vol.
S2652CO2-LD CO₂ 0-5% Vol.
S2445CO2-LD CO₂ 0-30% Vol.
S2630CO2-LD CO₂ 0-100% Vol.

SMART3G-C2-LD – SF₆ & Refrigerant Gases

Part Number Gas Type Range
S3944R32-LD R32 0-2000 ppm
S3596R134A-LD R134a 0-2000 ppm
S3599SF6-LD SF6 0-2000 ppm
S3656R125-LD R125 0-2000 ppm
S3657R1234YF-LD R1234yf 0-2000 ppm
S3948R1234ZE-LD R1234ze 0-2000 ppm
S3658R404A-LD R404A 0-2000 ppm
S3659R407A-LD R407A 0-2000 ppm
S3920R407F-LD R407F 0-2000 ppm
S3923R449A-LD R449A 0-2000 ppm
S3660R507A-LD R507A 0-2000 ppm
S3017R410A-LD R410A 0-2000 ppm
S3952R417A-LD R417A 0-2000 ppm
S3956R448-LD R448 0-2000 ppm

Accessories

Part Number Description
STS/CSW+ Calibration software with USB key, USB/RS485 converter, and STS/IDI card
STS/IDI RS485 plug-in communication interface
STS/CKD+ Calibration keypad with 7-digit display
STS/CKD-OLED Calibration keypad with OLED display and graphical visualization
STGD/AD3 Adapter to upgrade protection from G to GD
RE21-PNA1KONK ATEX cable gland for non-armoured cables
Sensor
Application Industrial area, ATEX Zone 1 and Zone 21 (when equipped with dust adapter, optional)
Sensing Element Infrared
Predicted Sensor Lifetime >5 years
Gas Detected Flammable, refrigerant and CO2 gases
Full Scale 0 – 100% LFL flammable gas
0 – 2000 ppm refrigerant gas
0-2%Vol; 0-5%Vol; 0-30%Vol; 0-100%Vol CO2
Electrical Data
Power Supply 12-24 Vdc
Output Analogue 4-20 mA output; 3 relay board; serial RS485 output (optional)
Maximum Dissipated Power 5.4 W
Relays Contact Ratings 1.0 A at 24 Vdc
Optical Indications Multi-colour LED light ring
Acoustic Indications
Environmental Conditions
Storage Temperature -40 / +85°C
Operating Temperature -40 / +60°C *
Operating Humidity 20 / 90% RH @40°C *
Operating Pressure 80 / 120 kPa *
Air Velocity 6 m/s *
Time of Response t90 < 60 s ; t50 < 20 s *
External Case
Material Enclosure: aluminium pressure die-casting with epoxy paint chromating and chemically resistant
Sensor head: stainless steel
Protection Mode Ex d : Explosion proof enclosure
Ex t : Equipment dust ignition protection by enclosure (when equipped with dust adapter, optional)
Dimensions 145 x 187 x 108 mm
Weight 1900 g
Cable Entries 3 x 3/4” NPT
IP Grade IP65
Compliance
EMC EN 61000-6-3:2007 + A1:2011; EN 50270:2015
ATEX ATEX directive 2014/34/UE
EN IEC 60079-0:2018
EN 60079-1:2014
EN 60079-31:2014
EN 60079-29-1:2016
IECEx IEC 60079-0:2011
IEC 60079-1:2014
IEC 60079-31:2013
SIL EN 61508:2010 Parts 1, 2, 3, 4, 5, 6, 7