SMART3-R is developed to detect gases in non-classified areas, such as machinery rooms and laboratories.
An infrared sensor detects flammable and refrigerant gases thanks to its high reliability and selectivity. 4 smart LEDs illuminate the transparent ring to describe the detector status and an internal buzzer is activated in alarm and fault conditions.
The SMART3-R gas detector has a standard 12-24 Vdc power supply, but a 220 Vac version can be supplied. The gas detector has three relay outputs, an RS485 serial communication and an analogue 4-20 mA output (not in the 220 Vac version).
The polycarbonate case has a global size of 130 x 130 x 74 mm. The box has two entries with M20 cable glands. Pre-formed guides can be drilled on the sides to add up to 6 M16 cable glands.
The gas detector can have a remote head connected with a RJ12 6P6C cable.
| Sensor Part Number | Description |
|---|---|
| SMART 3-R – FLAMMABLE GASES (Infrared sensor) | |
| S4591ME | METHANE detector, 4-20 mA, 0-100% LFL |
| S4592PR | PROPANE detector, 4-20 mA, 0-100% LFL |
| S4592BU | BUTANE detector, 4-20 mA, 0-100% LFL |
| S4592DE | R152a detector, 4-20 mA, 0-100% LFL |
| S4629R454B | R454B detector, 4-20 mA, 0-100% LFL |
| S4626R32 | R32 DIFLUOROMETHANE detector, 4-20 mA, 0-100% LFL |
| S4627R1234YF | R1234yf detector, 4-20 mA, 0-100% LFL |
| S4628R1234ZE | R1234ze detector, 4-20 mA, 0-100% LFL |
| SMART 3-R – CO2 (Infrared sensor) | |
| S4606CO2 | CARBON DIOXIDE (CO2) detector, 0-2% Vol., 4-20 mA |
| S4607CO2 | CARBON DIOXIDE (CO2) detector, 0-5% Vol., 4-20 mA |
| S4608CO2 | CARBON DIOXIDE (CO2) detector, 0-30% Vol., 4-20 mA |
| S4610CO2 | CARBON DIOXIDE (CO2) detector, 0-5000ppm, 4-20 mA |
| SMART 3-R – REFRIGERANT GASES (Infrared sensor) | |
| S4638R32 | R32 detector, 0-5000 ppm, 4-20 mA |
| S4639R134A | R134a detector, 0-5000 ppm, 4-20 mA |
| S4640R404A | R404A detector, 0-5000 ppm, 4-20 mA |
| S4641R407C | R407C detector, 0-5000 ppm, 4-20 mA |
| S4642R410A | R410A detector, 0-5000 ppm, 4-20 mA |
| S4643R1234YF | R1234yf detector, 0-5000 ppm, 4-20 mA |
| S4644R1234ZE | R1234ze detector, 0-5000 ppm, 4-20 mA |
| S4857R1233ZD | R1233Zd detector, 0-5000 ppm, 4-20 mA |
| S4611R32 | R32 detector, 0-2000 ppm, 4-20 mA |
| S4612R134A | R134A detector, 0-2000 ppm, 4-20 mA |
| S4613SF6 | SF6 detector, 0-2000 ppm, 4-20 mA |
| S4614R125 | R125 detector, 0-2000 ppm, 4-20 mA |
| S4615R1234YF | R1234yf detector, 0-2000 ppm, 4-20 mA |
| S4616R1234ZE | R1234ze detector, 0-2000 ppm, 4-20 mA |
| S4617R404A | R404A detector, 0-2000 ppm, 4-20 mA |
| S4618R407A | R407A detector, 0-2000 ppm, 4-20 mA |
| S4619R407F | R407F detector, 0-2000 ppm, 4-20 mA |
| S4620R449A | R449A detector, 0-2000 ppm, 4-20 mA |
| S4621R507A | R507A detector, 0-2000 ppm, 4-20 mA |
| S4622R410A | R410A detector, 0-2000 ppm, 4-20 mA |
| S4623R417A | R417A detector, 0-2000 ppm, 4-20 mA |
| S4624R448 | R448 detector, 0-2000 ppm, 4-20 mA |
| ACCESSORIES for SMART 3-R & SMART 3-R LITE | |
| STS/IDI | Plug-in RS485 interface enables SMART3NC detectors to communicate in Modbus protocol with MULTISCAN++S1, MULTISCAN 8+ & STPL4+D control panels |
| STS/CKD+ | Enhanced calibration keypad with 7-digit display and SD-CARD slot for Zero, Span, 4-20 mA adjustment and firmware updates |
| Sensing element | |
| Application | Machinery rooms, laboratories and non-classified areas |
| Sensing element | Infrared |
| Predicted life sensor | 5 years |
| Gas detected | CH4; C3H8; C4H10; R152a; R454B; R32; R1234YF; R1234ZE; R134a; R404A; R407C; R410A; SF6; R125; R407A; R407F; R449A; R507A; R417A; R448; CO2; R1233ZD |
| Fullscale |
0 – 100% LFL for flammable gases 0 – 5000 ppm o 0 – 2000 ppm for refrigerant gases 0-5000 ppm; 0-2%Vol; 0-5%Vol; 0-30%Vol for CO2 |
| Accuracy |
±1% fullscale for readings < 25% fullscale ±2% fullscale for readings < 50% fullscale ±5% fullscale for readings > 50% fullscale |
| Electrical data | |
| Power supply | 12-24 Vdc or 90-240Vac |
| Signal output | 3 relays; RS485 serial output, 4-20 mA analogue output (only for 12-24 Vdc version) |
| Dissipated power | 110 mA at 24 Vdc |
| Relays contact rating | 1.0 A at 30 Vdc |
| Optical indications | 4 smart LED |
| Acoustic indications | Buzzer 63 dB @1mt |
| Remote head cable | RJ12 6P6C |
| Environmental conditions | |
| Storage temperature | -40 / +85°C |
| Operating temperature |
-40 / +60°C 12-24 Vdc version -10 / +50°C infred sensor for ppm refrigerant gases |
| Operating temperature |
-40 / +50°C 230V version -10 / +50°C infred sensor for ppm refrigerant gases |
| Operating humidity | 0 / 95% RH non condensing |
| Compliance | |
| EMC | EN 61000-6-3:2007 + A1:201; EN 50270:2015 |
| Electrical safety (90-240 Vac version) | EN 61010-1: 2010 / A1: 2019 |
| Refrigeration Standards | EN 378-3; EN 14624; EN 50676; IEC 60335-2-40 Annex LL; ISO 5149-3; F-Gas Regulation |
| External case | |
| Material | Polycarbonate |
| Dimensions |
Box: 120 x 120 x 52 mm Cover: 130 x 130 x 22 mm Remote head box: 106 x 106 x 56 mm Maximum length of remote head’s cable: 5 m |
| Weight |
Detector: 450 g Remote head: 300 g |
| Cable entry |
2 entries with M20 cable glands 6 optional entries for M16 cable glands |
| IP Grade | IP42 |
Get in touch with us to see how we can help you with your project